ABAP Select data from SAP table CIF_PRODVR_EXT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CIF_PRODVR_EXT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CIF_PRODVR_EXT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CIF_PRODVR_EXT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CIF_PRODVR_EXT TYPE STANDARD TABLE OF CIF_PRODVR_EXT,
      WA_CIF_PRODVR_EXT TYPE CIF_PRODVR_EXT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CIF_PRODVR_EXT> TYPE CIF_PRODVR_EXT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CIF_PRODVR_EXT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CIF_PRODVR_EXT
  INTO TABLE IT_CIF_PRODVR_EXT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CIF_PRODVR_EXT
*  INTO TABLE @DATA(IT_CIF_PRODVR_EXT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CIF_PRODVR_EXT INDEX 1 INTO DATA(WA_CIF_PRODVR_EXT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CIF_PRODVR_EXT ASSIGNING <CIF_PRODVR_EXT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CIF_PRODVR_EXT>-PPMKEY_EX = 1.
<CIF_PRODVR_EXT>-METHOD = 1.
<CIF_PRODVR_EXT>-LOGCOMP = 1.
<CIF_PRODVR_EXT>-MATNR = 1.
<CIF_PRODVR_EXT>-LOCNO = 1.
ENDLOOP.

LOOP AT IT_CIF_PRODVR_EXT INTO WA_CIF_PRODVR_EXT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CIF_PRODVR_EXT-LOCTYPE, sy-vline,
WA_CIF_PRODVR_EXT-PLANKEY, sy-vline,
WA_CIF_PRODVR_EXT-DATEF, sy-vline,
WA_CIF_PRODVR_EXT-DATET, sy-vline,
WA_CIF_PRODVR_EXT-MINLS, sy-vline,
WA_CIF_PRODVR_EXT-MAXLS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CIF_PRODVR_EXT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CIF_PRODVR_EXT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CIF_PRODVR_EXT INTO WA_CIF_PRODVR_EXT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CIF_PRODVR_EXT_STR,
PPMKEY_EX TYPE STRING,
METHOD TYPE STRING,
LOGCOMP TYPE STRING,
MATNR TYPE STRING,
LOCNO TYPE STRING,
LOCTYPE TYPE STRING,
PLANKEY TYPE STRING,
DATEF TYPE STRING,
DATET TYPE STRING,
MINLS TYPE STRING,
MAXLS TYPE STRING,
PLANT TYPE STRING,
LOGCOMP_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_CIF_PRODVR_EXT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CIF_PRODVR_EXT_STR-PPMKEY_EX sy-vline
WA_CIF_PRODVR_EXT_STR-METHOD sy-vline
WA_CIF_PRODVR_EXT_STR-LOGCOMP sy-vline
WA_CIF_PRODVR_EXT_STR-MATNR sy-vline
WA_CIF_PRODVR_EXT_STR-LOCNO sy-vline
WA_CIF_PRODVR_EXT_STR-LOCTYPE sy-vline
WA_CIF_PRODVR_EXT_STR-PLANKEY sy-vline
WA_CIF_PRODVR_EXT_STR-DATEF sy-vline
WA_CIF_PRODVR_EXT_STR-DATET sy-vline
WA_CIF_PRODVR_EXT_STR-MINLS sy-vline
WA_CIF_PRODVR_EXT_STR-MAXLS sy-vline
WA_CIF_PRODVR_EXT_STR-PLANT sy-vline
WA_CIF_PRODVR_EXT_STR-LOGCOMP_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.