ABAP Select data from SAP table CIF_PRJACT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CIF_PRJACT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CIF_PRJACT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CIF_PRJACT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CIF_PRJACT TYPE STANDARD TABLE OF CIF_PRJACT,
      WA_CIF_PRJACT TYPE CIF_PRJACT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CIF_PRJACT> TYPE CIF_PRJACT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CIF_PRJACT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CIF_PRJACT
  INTO TABLE IT_CIF_PRJACT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CIF_PRJACT
*  INTO TABLE @DATA(IT_CIF_PRJACT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CIF_PRJACT INDEX 1 INTO DATA(WA_CIF_PRJACT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CIF_PRJACT ASSIGNING <CIF_PRJACT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CIF_PRJACT>-ORDNO = 1.
<CIF_PRJACT>-OPRCOUNTER = 1.
<CIF_PRJACT>-LOCATION = 1.
<CIF_PRJACT>-OPRNR = 1.
<CIF_PRJACT>-STARTTI = 1.
ENDLOOP.

LOOP AT IT_CIF_PRJACT INTO WA_CIF_PRJACT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CIF_PRJACT-ENDTI, sy-vline,
WA_CIF_PRJACT-CONF_START, sy-vline,
WA_CIF_PRJACT-CONF_END, sy-vline,
WA_CIF_PRJACT-FIX_TIMES, sy-vline,
WA_CIF_PRJACT-RELEASED, sy-vline,
WA_CIF_PRJACT-PART_CONF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CIF_PRJACT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CIF_PRJACT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CIF_PRJACT INTO WA_CIF_PRJACT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ORDNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CIF_PRJACT-ORDNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CIF_PRJACT-ORDNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field OPRNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CIF_PRJACT-OPRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CIF_PRJACT-OPRNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CIF_PRJACT_STR,
ORDNO TYPE STRING,
OPRCOUNTER TYPE STRING,
LOCATION TYPE STRING,
OPRNR TYPE STRING,
STARTTI TYPE STRING,
ENDTI TYPE STRING,
CONF_START TYPE STRING,
CONF_END TYPE STRING,
FIX_TIMES TYPE STRING,
RELEASED TYPE STRING,
PART_CONF TYPE STRING,
FINAL_CONF TYPE STRING,
PROC_TIME TYPE STRING,
REM_TIME TYPE STRING,
WBS_ID TYPE STRING,
WBS_EXT TYPE STRING,
STEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CIF_PRJACT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CIF_PRJACT_STR-ORDNO sy-vline
WA_CIF_PRJACT_STR-OPRCOUNTER sy-vline
WA_CIF_PRJACT_STR-LOCATION sy-vline
WA_CIF_PRJACT_STR-OPRNR sy-vline
WA_CIF_PRJACT_STR-STARTTI sy-vline
WA_CIF_PRJACT_STR-ENDTI sy-vline
WA_CIF_PRJACT_STR-CONF_START sy-vline
WA_CIF_PRJACT_STR-CONF_END sy-vline
WA_CIF_PRJACT_STR-FIX_TIMES sy-vline
WA_CIF_PRJACT_STR-RELEASED sy-vline
WA_CIF_PRJACT_STR-PART_CONF sy-vline
WA_CIF_PRJACT_STR-FINAL_CONF sy-vline
WA_CIF_PRJACT_STR-PROC_TIME sy-vline
WA_CIF_PRJACT_STR-REM_TIME sy-vline
WA_CIF_PRJACT_STR-WBS_ID sy-vline
WA_CIF_PRJACT_STR-WBS_EXT sy-vline
WA_CIF_PRJACT_STR-STEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.