ABAP Select data from SAP table CI_P9996 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CI_P9996 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CI_P9996. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CI_P9996 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CI_P9996 TYPE STANDARD TABLE OF CI_P9996,
      WA_CI_P9996 TYPE CI_P9996,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CI_P9996> TYPE CI_P9996.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CI_P9996.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CI_P9996
  INTO TABLE IT_CI_P9996.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CI_P9996
*  INTO TABLE @DATA(IT_CI_P99962).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CI_P9996 INDEX 1 INTO DATA(WA_CI_P99962).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CI_P9996 ASSIGNING <CI_P9996>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CI_P9996>-ZZTEL0163B = 1.
<CI_P9996>-ZZTEL0167B = 1.
<CI_P9996>-ZZTEL0171B = 1.
<CI_P9996>-ZZTEL0175B = 1.
<CI_P9996>-ZZTEL0179B = 1.
ENDLOOP.

LOOP AT IT_CI_P9996 INTO WA_CI_P9996.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CI_P9996-ZZTEL0183B, sy-vline,
WA_CI_P9996-ZZTEL0187B, sy-vline,
WA_CI_P9996-ZZTEL0191B, sy-vline,
WA_CI_P9996-ZZTEL0195B, sy-vline,
WA_CI_P9996-ZZTEL0199B, sy-vline,
WA_CI_P9996-ZZTEL0207B, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CI_P9996 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CI_P9996 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CI_P9996 INTO WA_CI_P9996. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CI_P9996_STR,
ZZTEL0163B TYPE STRING,
ZZTEL0167B TYPE STRING,
ZZTEL0171B TYPE STRING,
ZZTEL0175B TYPE STRING,
ZZTEL0179B TYPE STRING,
ZZTEL0183B TYPE STRING,
ZZTEL0187B TYPE STRING,
ZZTEL0191B TYPE STRING,
ZZTEL0195B TYPE STRING,
ZZTEL0199B TYPE STRING,
ZZTEL0207B TYPE STRING,
ZZTEL0211B TYPE STRING,
ZZTEL0215B TYPE STRING,
ZZTEL0223B TYPE STRING,
ZZTEL0227B TYPE STRING,
ZZTEL0231B TYPE STRING,
ZZTEL0235B TYPE STRING,
ZZTEL0239B TYPE STRING,
ZZTEL0243B TYPE STRING,END OF T_EKKO_STR. DATA: WA_CI_P9996_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CI_P9996_STR-ZZTEL0163B sy-vline
WA_CI_P9996_STR-ZZTEL0167B sy-vline
WA_CI_P9996_STR-ZZTEL0171B sy-vline
WA_CI_P9996_STR-ZZTEL0175B sy-vline
WA_CI_P9996_STR-ZZTEL0179B sy-vline
WA_CI_P9996_STR-ZZTEL0183B sy-vline
WA_CI_P9996_STR-ZZTEL0187B sy-vline
WA_CI_P9996_STR-ZZTEL0191B sy-vline
WA_CI_P9996_STR-ZZTEL0195B sy-vline
WA_CI_P9996_STR-ZZTEL0199B sy-vline
WA_CI_P9996_STR-ZZTEL0207B sy-vline
WA_CI_P9996_STR-ZZTEL0211B sy-vline
WA_CI_P9996_STR-ZZTEL0215B sy-vline
WA_CI_P9996_STR-ZZTEL0223B sy-vline
WA_CI_P9996_STR-ZZTEL0227B sy-vline
WA_CI_P9996_STR-ZZTEL0231B sy-vline
WA_CI_P9996_STR-ZZTEL0235B sy-vline
WA_CI_P9996_STR-ZZTEL0239B sy-vline
WA_CI_P9996_STR-ZZTEL0243B sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.