ABAP Select data from SAP table CFG_V399X into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CFG_V399X table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CFG_V399X. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CFG_V399X table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CFG_V399X TYPE STANDARD TABLE OF CFG_V399X,
      WA_CFG_V399X TYPE CFG_V399X,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CFG_V399X> TYPE CFG_V399X.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CFG_V399X.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CFG_V399X
  INTO TABLE IT_CFG_V399X.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CFG_V399X
*  INTO TABLE @DATA(IT_CFG_V399X2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CFG_V399X INDEX 1 INTO DATA(WA_CFG_V399X2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CFG_V399X ASSIGNING <CFG_V399X>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CFG_V399X>-WERKS = 1.
<CFG_V399X>-AUART = 1.
<CFG_V399X>-PLNTY = 1.
<CFG_V399X>-PRF_GROUPE = 1.
<CFG_V399X>-PRF_NAME = 1.
ENDLOOP.

LOOP AT IT_CFG_V399X INTO WA_CFG_V399X.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CFG_V399X-PRF_INDEX, sy-vline,
WA_CFG_V399X-DFREG, sy-vline,
WA_CFG_V399X-ARBPA, sy-vline,
WA_CFG_V399X-CAPID, sy-vline,
WA_CFG_V399X-CPSLID, sy-vline,
WA_CFG_V399X-KLVARP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CFG_V399X you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CFG_V399X TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CFG_V399X INTO WA_CFG_V399X. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DFREG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CFG_V399X-DFREG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CFG_V399X-DFREG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR_DEL CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CFG_V399X-VORNR_DEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CFG_V399X-VORNR_DEL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CFG_V399X_STR,
WERKS TYPE STRING,
AUART TYPE STRING,
PLNTY TYPE STRING,
PRF_GROUPE TYPE STRING,
PRF_NAME TYPE STRING,
PRF_INDEX TYPE STRING,
DFREG TYPE STRING,
ARBPA TYPE STRING,
CAPID TYPE STRING,
CPSLID TYPE STRING,
KLVARP TYPE STRING,
KLVARI TYPE STRING,
ABGSL TYPE STRING,
ALTSEQ TYPE STRING,
VORNR_DEL TYPE STRING,
FLG_ERF_H TYPE STRING,
RSTRA TYPE STRING,
STATISTIK TYPE STRING,
OBJNR_VORG TYPE STRING,
FLG_STAT TYPE STRING,
SEQ_CHANGE TYPE STRING,
CHGKZ_HEAD TYPE STRING,
CHGKZ_OPR TYPE STRING,
CHGKZ_CMP TYPE STRING,
CHGKZ_PRT TYPE STRING,
PLTRM TYPE STRING,
PROFIDGRAF TYPE STRING,
VRG_DARST TYPE STRING,
PHS_DARST TYPE STRING,
NAUCOST TYPE STRING,
STRAT TYPE STRING,
CHSCH TYPE STRING,
MC_VHEAD TYPE STRING,
MC_VITEM TYPE STRING,
MC_VOPER TYPE STRING,
PRUEB TYPE STRING,
WF_MAT_CHG TYPE STRING,
PDC_ACTIVE TYPE STRING,
NO_DISP TYPE STRING,
AUTYP_X TYPE STRING,
PROF_GR TYPE STRING,
PRUEFART TYPE STRING,
ORD_BANF TYPE STRING,
MBWEB TYPE STRING,
MBWEF TYPE STRING,
MBWAP TYPE STRING,
MBWAU TYPE STRING,
NOPCOST TYPE STRING,
KZCHP TYPE STRING,
PVSEL TYPE STRING,
FTLPROF TYPE STRING,
FTLPROFNET TYPE STRING,
PKOSA TYPE STRING,
KZFORT TYPE STRING,
ROUT_TEXT TYPE STRING,
FLG_READ TYPE STRING,END OF T_EKKO_STR. DATA: WA_CFG_V399X_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CFG_V399X_STR-WERKS sy-vline
WA_CFG_V399X_STR-AUART sy-vline
WA_CFG_V399X_STR-PLNTY sy-vline
WA_CFG_V399X_STR-PRF_GROUPE sy-vline
WA_CFG_V399X_STR-PRF_NAME sy-vline
WA_CFG_V399X_STR-PRF_INDEX sy-vline
WA_CFG_V399X_STR-DFREG sy-vline
WA_CFG_V399X_STR-ARBPA sy-vline
WA_CFG_V399X_STR-CAPID sy-vline
WA_CFG_V399X_STR-CPSLID sy-vline
WA_CFG_V399X_STR-KLVARP sy-vline
WA_CFG_V399X_STR-KLVARI sy-vline
WA_CFG_V399X_STR-ABGSL sy-vline
WA_CFG_V399X_STR-ALTSEQ sy-vline
WA_CFG_V399X_STR-VORNR_DEL sy-vline
WA_CFG_V399X_STR-FLG_ERF_H sy-vline
WA_CFG_V399X_STR-RSTRA sy-vline
WA_CFG_V399X_STR-STATISTIK sy-vline
WA_CFG_V399X_STR-OBJNR_VORG sy-vline
WA_CFG_V399X_STR-FLG_STAT sy-vline
WA_CFG_V399X_STR-SEQ_CHANGE sy-vline
WA_CFG_V399X_STR-CHGKZ_HEAD sy-vline
WA_CFG_V399X_STR-CHGKZ_OPR sy-vline
WA_CFG_V399X_STR-CHGKZ_CMP sy-vline
WA_CFG_V399X_STR-CHGKZ_PRT sy-vline
WA_CFG_V399X_STR-PLTRM sy-vline
WA_CFG_V399X_STR-PROFIDGRAF sy-vline
WA_CFG_V399X_STR-VRG_DARST sy-vline
WA_CFG_V399X_STR-PHS_DARST sy-vline
WA_CFG_V399X_STR-NAUCOST sy-vline
WA_CFG_V399X_STR-STRAT sy-vline
WA_CFG_V399X_STR-CHSCH sy-vline
WA_CFG_V399X_STR-MC_VHEAD sy-vline
WA_CFG_V399X_STR-MC_VITEM sy-vline
WA_CFG_V399X_STR-MC_VOPER sy-vline
WA_CFG_V399X_STR-PRUEB sy-vline
WA_CFG_V399X_STR-WF_MAT_CHG sy-vline
WA_CFG_V399X_STR-PDC_ACTIVE sy-vline
WA_CFG_V399X_STR-NO_DISP sy-vline
WA_CFG_V399X_STR-AUTYP_X sy-vline
WA_CFG_V399X_STR-PROF_GR sy-vline
WA_CFG_V399X_STR-PRUEFART sy-vline
WA_CFG_V399X_STR-ORD_BANF sy-vline
WA_CFG_V399X_STR-MBWEB sy-vline
WA_CFG_V399X_STR-MBWEF sy-vline
WA_CFG_V399X_STR-MBWAP sy-vline
WA_CFG_V399X_STR-MBWAU sy-vline
WA_CFG_V399X_STR-NOPCOST sy-vline
WA_CFG_V399X_STR-KZCHP sy-vline
WA_CFG_V399X_STR-PVSEL sy-vline
WA_CFG_V399X_STR-FTLPROF sy-vline
WA_CFG_V399X_STR-FTLPROFNET sy-vline
WA_CFG_V399X_STR-PKOSA sy-vline
WA_CFG_V399X_STR-KZFORT sy-vline
WA_CFG_V399X_STR-ROUT_TEXT sy-vline
WA_CFG_V399X_STR-FLG_READ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.