ABAP Select data from SAP table CFEORGPTRELSHPTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CFEORGPTRELSHPTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CFEORGPTRELSHPTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CFEORGPTRELSHPTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CFEORGPTRELSHPTP TYPE STANDARD TABLE OF CFEORGPTRELSHPTP,
      WA_CFEORGPTRELSHPTP TYPE CFEORGPTRELSHPTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CFEORGPTRELSHPTP> TYPE CFEORGPTRELSHPTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CFEORGPTRELSHPTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CFEORGPTRELSHPTP
  INTO TABLE IT_CFEORGPTRELSHPTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CFEORGPTRELSHPTP
*  INTO TABLE @DATA(IT_CFEORGPTRELSHPTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CFEORGPTRELSHPTP INDEX 1 INTO DATA(WA_CFEORGPTRELSHPTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CFEORGPTRELSHPTP ASSIGNING <CFEORGPTRELSHPTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CFEORGPTRELSHPTP>-MANDT = 1.
<CFEORGPTRELSHPTP>-FRCELMNTORGCONCATENATEDID = 1.
<CFEORGPTRELSHPTP>-FRCELMNTORGRELATEDORGID = 1.
<CFEORGPTRELSHPTP>-FRCELMNTORGVALDTYSTARTDATE = 1.
<CFEORGPTRELSHPTP>-FRCELMNTORGVALDTYENDDATE = 1.
ENDLOOP.

LOOP AT IT_CFEORGPTRELSHPTP INTO WA_CFEORGPTRELSHPTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CFEORGPTRELSHPTP-FRCELMNTORGSUBTYPE, sy-vline,
WA_CFEORGPTRELSHPTP-FRCELMNTORGPLNGSTATUS, sy-vline,
WA_CFEORGPTRELSHPTP-FRCELMNTORGDRAFTUUID, sy-vline,
WA_CFEORGPTRELSHPTP-FORCEELEMENTORGID, sy-vline,
WA_CFEORGPTRELSHPTP-FRCELMNTORGNAME, sy-vline,
WA_CFEORGPTRELSHPTP-FRCELMNTORGNAMEFOED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CFEORGPTRELSHPTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CFEORGPTRELSHPTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CFEORGPTRELSHPTP INTO WA_CFEORGPTRELSHPTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CFEORGPTRELSHPTP_STR,
MANDT TYPE STRING,
FRCELMNTORGCONCATENATEDID TYPE STRING,
FRCELMNTORGRELATEDORGID TYPE STRING,
FRCELMNTORGVALDTYSTARTDATE TYPE STRING,
FRCELMNTORGVALDTYENDDATE TYPE STRING,
FRCELMNTORGSUBTYPE TYPE STRING,
FRCELMNTORGPLNGSTATUS TYPE STRING,
FRCELMNTORGDRAFTUUID TYPE STRING,
FORCEELEMENTORGID TYPE STRING,
FRCELMNTORGNAME TYPE STRING,
FRCELMNTORGNAMEFOED TYPE STRING,
NUMBEROFFORCEELEMENTORG TYPE STRING,
FRCELMNTORGPLANVERSION TYPE STRING,
FRCELMNTORGTYPE TYPE STRING,
FRCELMNTORGINFOTYPE TYPE STRING,
FRCELMNTORGRELATEDORGTYPE TYPE STRING,
FRCELMNTORGRELSHPPRIORITY TYPE STRING,
FRCELMNTORGPLNGSTATUSFOED TYPE STRING,
FRCELMNTORGRELSHPDESC TYPE STRING,
FRCELMNTORGRELSHPSPEC TYPE STRING,
FORCEELEMENTORGIDFOREDIT TYPE STRING,
FRCELMNTORGRELATEDORGIDFOREDIT TYPE STRING,
FRCELMNTORGVALDTYSTARTDATEFOED TYPE STRING,
FRCELMNTORGVALDTYENDDATEFOED TYPE STRING,
FRCELMNTORGPLNGSTATUSFOREDIT TYPE STRING,
FRCELMNTORGCNCTNTDRELSHPNAME TYPE STRING,
FRCELMNTORGTECHNICALSTATUSNAME TYPE STRING,
CRITICALITY TYPE STRING,
FRCELMNTORGPLNGSTATUSNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_CFEORGPTRELSHPTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CFEORGPTRELSHPTP_STR-MANDT sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGCONCATENATEDID sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGRELATEDORGID sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGVALDTYSTARTDATE sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGVALDTYENDDATE sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGSUBTYPE sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGPLNGSTATUS sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGDRAFTUUID sy-vline
WA_CFEORGPTRELSHPTP_STR-FORCEELEMENTORGID sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGNAME sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGNAMEFOED sy-vline
WA_CFEORGPTRELSHPTP_STR-NUMBEROFFORCEELEMENTORG sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGPLANVERSION sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGTYPE sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGINFOTYPE sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGRELATEDORGTYPE sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGRELSHPPRIORITY sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGPLNGSTATUSFOED sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGRELSHPDESC sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGRELSHPSPEC sy-vline
WA_CFEORGPTRELSHPTP_STR-FORCEELEMENTORGIDFOREDIT sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGRELATEDORGIDFOREDIT sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGVALDTYSTARTDATEFOED sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGVALDTYENDDATEFOED sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGPLNGSTATUSFOREDIT sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGCNCTNTDRELSHPNAME sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGTECHNICALSTATUSNAME sy-vline
WA_CFEORGPTRELSHPTP_STR-CRITICALITY sy-vline
WA_CFEORGPTRELSHPTP_STR-FRCELMNTORGPLNGSTATUSNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.