ABAP Select data from SAP table CFECSTCTRRLUNON into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CFECSTCTRRLUNON table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CFECSTCTRRLUNON. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CFECSTCTRRLUNON table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CFECSTCTRRLUNON TYPE STANDARD TABLE OF CFECSTCTRRLUNON,
      WA_CFECSTCTRRLUNON TYPE CFECSTCTRRLUNON,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CFECSTCTRRLUNON> TYPE CFECSTCTRRLUNON.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CFECSTCTRRLUNON.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CFECSTCTRRLUNON
  INTO TABLE IT_CFECSTCTRRLUNON.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CFECSTCTRRLUNON
*  INTO TABLE @DATA(IT_CFECSTCTRRLUNON2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CFECSTCTRRLUNON INDEX 1 INTO DATA(WA_CFECSTCTRRLUNON2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CFECSTCTRRLUNON ASSIGNING <CFECSTCTRRLUNON>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CFECSTCTRRLUNON>-MANDT = 1.
<CFECSTCTRRLUNON>-DFSOBJECTID = 1.
<CFECSTCTRRLUNON>-DFSOBJECTRELATEDOBJECTID = 1.
<CFECSTCTRRLUNON>-DFSOBJECTDRAFTUUID = 1.
<CFECSTCTRRLUNON>-DFSOBJECTVALDTYSTARTDATE = 1.
ENDLOOP.

LOOP AT IT_CFECSTCTRRLUNON INTO WA_CFECSTCTRRLUNON.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CFECSTCTRRLUNON-DFSOBJECTVALDTYENDDATE, sy-vline,
WA_CFECSTCTRRLUNON-DFSOBJECTPLNGSTATUS, sy-vline,
WA_CFECSTCTRRLUNON-DFSOBJECTPLANVERSION, sy-vline,
WA_CFECSTCTRRLUNON-DFSASSGMTTECHNICALSTATUSDESC, sy-vline,
WA_CFECSTCTRRLUNON-DFSASSGMTACTIVEDRAFT, sy-vline,
WA_CFECSTCTRRLUNON-DFSOBJECTTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CFECSTCTRRLUNON you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CFECSTCTRRLUNON TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CFECSTCTRRLUNON INTO WA_CFECSTCTRRLUNON. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CFECSTCTRRLUNON_STR,
MANDT TYPE STRING,
DFSOBJECTID TYPE STRING,
DFSOBJECTRELATEDOBJECTID TYPE STRING,
DFSOBJECTDRAFTUUID TYPE STRING,
DFSOBJECTVALDTYSTARTDATE TYPE STRING,
DFSOBJECTVALDTYENDDATE TYPE STRING,
DFSOBJECTPLNGSTATUS TYPE STRING,
DFSOBJECTPLANVERSION TYPE STRING,
DFSASSGMTTECHNICALSTATUSDESC TYPE STRING,
DFSASSGMTACTIVEDRAFT TYPE STRING,
DFSOBJECTTYPE TYPE STRING,
DFSOBJECTRELSHPSPEC TYPE STRING,
DFSOBJECTRELSHPBTWNOBJ TYPE STRING,
FRCELMNTORGPLNGSTSCRITLTY TYPE STRING,
DFSOBJECTRELSHPPRIORITY TYPE STRING,
NUMBEROFFORCEELEMENTORG TYPE STRING,
DFSOBJECTINFOTYPE TYPE STRING,
DFSOBJECTCONCATENATEDID TYPE STRING,
DFSOBJECTSUBTYPE TYPE STRING,
DFSOBJECTRELATEDOBJECTTYPE TYPE STRING,
DFSOBJRELSHPLASTCHGDBYUSERNAME TYPE STRING,
DFSOBJRELSHPLASTCHGDBYUSER TYPE STRING,
DFSOBJRELSHPLASTCHGDDATE TYPE STRING,
ISACTIVEENTITY TYPE STRING,
FRCELMNTORGPLNGSTATUSNAME TYPE STRING,
HASACTIVEENTITY TYPE STRING,
HASDRAFTENTITY TYPE STRING,
CRITICALITY TYPE STRING,
FRCELMNTORGCONTROLLINGAREA TYPE STRING,
CONTROLLINGAREA TYPE STRING,
FRCELMNTORGCOSTCENTER TYPE STRING,
FRCELMNTORGTYPE TYPE STRING,
FORCEELEMENTORGUUID TYPE STRING,
FRCELMNTORGNAME TYPE STRING,
FRCELMNTORGPLANVERSION TYPE STRING,
FRCELMNTORGSYMBOL TYPE STRING,
FORCEELEMENTORGID TYPE STRING,
COSTCENTERNAME TYPE STRING,
CONTROLLINGAREANAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_CFECSTCTRRLUNON_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CFECSTCTRRLUNON_STR-MANDT sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTID sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTRELATEDOBJECTID sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTDRAFTUUID sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTVALDTYSTARTDATE sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTVALDTYENDDATE sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTPLNGSTATUS sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTPLANVERSION sy-vline
WA_CFECSTCTRRLUNON_STR-DFSASSGMTTECHNICALSTATUSDESC sy-vline
WA_CFECSTCTRRLUNON_STR-DFSASSGMTACTIVEDRAFT sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTTYPE sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTRELSHPSPEC sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTRELSHPBTWNOBJ sy-vline
WA_CFECSTCTRRLUNON_STR-FRCELMNTORGPLNGSTSCRITLTY sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTRELSHPPRIORITY sy-vline
WA_CFECSTCTRRLUNON_STR-NUMBEROFFORCEELEMENTORG sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTINFOTYPE sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTCONCATENATEDID sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTSUBTYPE sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJECTRELATEDOBJECTTYPE sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJRELSHPLASTCHGDBYUSERNAME sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJRELSHPLASTCHGDBYUSER sy-vline
WA_CFECSTCTRRLUNON_STR-DFSOBJRELSHPLASTCHGDDATE sy-vline
WA_CFECSTCTRRLUNON_STR-ISACTIVEENTITY sy-vline
WA_CFECSTCTRRLUNON_STR-FRCELMNTORGPLNGSTATUSNAME sy-vline
WA_CFECSTCTRRLUNON_STR-HASACTIVEENTITY sy-vline
WA_CFECSTCTRRLUNON_STR-HASDRAFTENTITY sy-vline
WA_CFECSTCTRRLUNON_STR-CRITICALITY sy-vline
WA_CFECSTCTRRLUNON_STR-FRCELMNTORGCONTROLLINGAREA sy-vline
WA_CFECSTCTRRLUNON_STR-CONTROLLINGAREA sy-vline
WA_CFECSTCTRRLUNON_STR-FRCELMNTORGCOSTCENTER sy-vline
WA_CFECSTCTRRLUNON_STR-FRCELMNTORGTYPE sy-vline
WA_CFECSTCTRRLUNON_STR-FORCEELEMENTORGUUID sy-vline
WA_CFECSTCTRRLUNON_STR-FRCELMNTORGNAME sy-vline
WA_CFECSTCTRRLUNON_STR-FRCELMNTORGPLANVERSION sy-vline
WA_CFECSTCTRRLUNON_STR-FRCELMNTORGSYMBOL sy-vline
WA_CFECSTCTRRLUNON_STR-FORCEELEMENTORGID sy-vline
WA_CFECSTCTRRLUNON_STR-COSTCENTERNAME sy-vline
WA_CFECSTCTRRLUNON_STR-CONTROLLINGAREANAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.