ABAP Select data from SAP table CFD_L_DEL_BUS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CFD_L_DEL_BUS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CFD_L_DEL_BUS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CFD_L_DEL_BUS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CFD_L_DEL_BUS TYPE STANDARD TABLE OF CFD_L_DEL_BUS,
      WA_CFD_L_DEL_BUS TYPE CFD_L_DEL_BUS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CFD_L_DEL_BUS> TYPE CFD_L_DEL_BUS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CFD_L_DEL_BUS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CFD_L_DEL_BUS
  INTO TABLE IT_CFD_L_DEL_BUS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CFD_L_DEL_BUS
*  INTO TABLE @DATA(IT_CFD_L_DEL_BUS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CFD_L_DEL_BUS INDEX 1 INTO DATA(WA_CFD_L_DEL_BUS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CFD_L_DEL_BUS ASSIGNING <CFD_L_DEL_BUS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CFD_L_DEL_BUS>-NAME = 1.
<CFD_L_DEL_BUS>-VERSION = 1.
<CFD_L_DEL_BUS>-BUSINESS_CONTEXT = 1.
<CFD_L_DEL_BUS>-IS_ADDED = 1.
<CFD_L_DEL_BUS>-DEVIATING_FIELD_NAME = 1.
ENDLOOP.

LOOP AT IT_CFD_L_DEL_BUS INTO WA_CFD_L_DEL_BUS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CFD_L_DEL_BUS-PERSISTENCE_INCLUDE, sy-vline,
WA_CFD_L_DEL_BUS-PERSISTENCE_CONTEXT_SUFFIX, sy-vline,
WA_CFD_L_DEL_BUS-TRANSIENT_FIELDS_INCLUDE, sy-vline,
WA_CFD_L_DEL_BUS-CHANGE_INDICATOR_INCLUDE, sy-vline,
WA_CFD_L_DEL_BUS-FIELD_CONTROL_INCLUDE, sy-vline,
WA_CFD_L_DEL_BUS-UPPERCASE_ONLY_CODE_LISTS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CFD_L_DEL_BUS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CFD_L_DEL_BUS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CFD_L_DEL_BUS INTO WA_CFD_L_DEL_BUS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CFD_L_DEL_BUS_STR,
NAME TYPE STRING,
VERSION TYPE STRING,
BUSINESS_CONTEXT TYPE STRING,
IS_ADDED TYPE STRING,
DEVIATING_FIELD_NAME TYPE STRING,
PERSISTENCE_INCLUDE TYPE STRING,
PERSISTENCE_CONTEXT_SUFFIX TYPE STRING,
TRANSIENT_FIELDS_INCLUDE TYPE STRING,
CHANGE_INDICATOR_INCLUDE TYPE STRING,
FIELD_CONTROL_INCLUDE TYPE STRING,
UPPERCASE_ONLY_CODE_LISTS TYPE STRING,
VIEW_INCLUDE TYPE STRING,
DRAFT_VIEW_INCLUDE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CFD_L_DEL_BUS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CFD_L_DEL_BUS_STR-NAME sy-vline
WA_CFD_L_DEL_BUS_STR-VERSION sy-vline
WA_CFD_L_DEL_BUS_STR-BUSINESS_CONTEXT sy-vline
WA_CFD_L_DEL_BUS_STR-IS_ADDED sy-vline
WA_CFD_L_DEL_BUS_STR-DEVIATING_FIELD_NAME sy-vline
WA_CFD_L_DEL_BUS_STR-PERSISTENCE_INCLUDE sy-vline
WA_CFD_L_DEL_BUS_STR-PERSISTENCE_CONTEXT_SUFFIX sy-vline
WA_CFD_L_DEL_BUS_STR-TRANSIENT_FIELDS_INCLUDE sy-vline
WA_CFD_L_DEL_BUS_STR-CHANGE_INDICATOR_INCLUDE sy-vline
WA_CFD_L_DEL_BUS_STR-FIELD_CONTROL_INCLUDE sy-vline
WA_CFD_L_DEL_BUS_STR-UPPERCASE_ONLY_CODE_LISTS sy-vline
WA_CFD_L_DEL_BUS_STR-VIEW_INCLUDE sy-vline
WA_CFD_L_DEL_BUS_STR-DRAFT_VIEW_INCLUDE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.