ABAP Select data from SAP table CFCCERRTSTQ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CFCCERRTSTQ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CFCCERRTSTQ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CFCCERRTSTQ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CFCCERRTSTQ TYPE STANDARD TABLE OF CFCCERRTSTQ,
      WA_CFCCERRTSTQ TYPE CFCCERRTSTQ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CFCCERRTSTQ> TYPE CFCCERRTSTQ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CFCCERRTSTQ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CFCCERRTSTQ
  INTO TABLE IT_CFCCERRTSTQ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CFCCERRTSTQ
*  INTO TABLE @DATA(IT_CFCCERRTSTQ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CFCCERRTSTQ INDEX 1 INTO DATA(WA_CFCCERRTSTQ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CFCCERRTSTQ ASSIGNING <CFCCERRTSTQ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CFCCERRTSTQ>-MANDT = 1.
<CFCCERRTSTQ>-CLOSINGTEMPLATE = 1.
<CFCCERRTSTQ>-CLOSINGTASKLISTINSTANCE = 1.
<CFCCERRTSTQ>-CLOSINGTASK = 1.
<CFCCERRTSTQ>-CLOSINGTASKSTATUS = 1.
ENDLOOP.

LOOP AT IT_CFCCERRTSTQ INTO WA_CFCCERRTSTQ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CFCCERRTSTQ-CLOSINGTASKSTATUSCHANGEDATE, sy-vline,
WA_CFCCERRTSTQ-CLOSINGTASKSTATUSCHANGETIME, sy-vline,
WA_CFCCERRTSTQ-CLSGTASKSTATUSCHANGEDBYUSER, sy-vline,
WA_CFCCERRTSTQ-CLSGTASKSTATUSCHGREASONDESC, sy-vline,
WA_CFCCERRTSTQ-CLSGTASKSTATUSISCHGDMANUALLY, sy-vline,
WA_CFCCERRTSTQ-CLOSINGTASKTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CFCCERRTSTQ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CFCCERRTSTQ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CFCCERRTSTQ INTO WA_CFCCERRTSTQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field FISCALYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_CFCCERRTSTQ-FISCALYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CFCCERRTSTQ-FISCALYEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CFCCERRTSTQ_STR,
MANDT TYPE STRING,
CLOSINGTEMPLATE TYPE STRING,
CLOSINGTASKLISTINSTANCE TYPE STRING,
CLOSINGTASK TYPE STRING,
CLOSINGTASKSTATUS TYPE STRING,
CLOSINGTASKSTATUSCHANGEDATE TYPE STRING,
CLOSINGTASKSTATUSCHANGETIME TYPE STRING,
CLSGTASKSTATUSCHANGEDBYUSER TYPE STRING,
CLSGTASKSTATUSCHGREASONDESC TYPE STRING,
CLSGTASKSTATUSISCHGDMANUALLY TYPE STRING,
CLOSINGTASKTYPE TYPE STRING,
CLOSINGTASKNAME TYPE STRING,
ISCRITICALPATH TYPE STRING,
CLOSINGTASKPROCESSOR TYPE STRING,
CLOSINGTASKPROCESSORTYPE TYPE STRING,
CLOSINGTASKRESPONSIBLE TYPE STRING,
CLOSINGTASKRESPONSIBLETYPE TYPE STRING,
CLOSINGTASKGLOBALID TYPE STRING,
CUSTOMDIMENSION1 TYPE STRING,
CUSTOMDIMENSION2 TYPE STRING,
CUSTOMDIMENSION3 TYPE STRING,
CLOSINGMILESTONE TYPE STRING,
CLOSINGPHASE TYPE STRING,
KEYDATE TYPE STRING,
CLOSINGAUTHORIZATIONGROUP TYPE STRING,
FISCALYEAR TYPE STRING,
FISCALYEARPERIOD TYPE STRING,
NMBROFCMPLTDWITHERRORCLSGTASKS TYPE STRING,
PLANNEDSTARTDATE TYPE STRING,
PLANNEDENDDATE TYPE STRING,
PLANNEDSTARTTIME TYPE STRING,
PLANNEDENDTIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_CFCCERRTSTQ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CFCCERRTSTQ_STR-MANDT sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTEMPLATE sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASKLISTINSTANCE sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASK sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASKSTATUS sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASKSTATUSCHANGEDATE sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASKSTATUSCHANGETIME sy-vline
WA_CFCCERRTSTQ_STR-CLSGTASKSTATUSCHANGEDBYUSER sy-vline
WA_CFCCERRTSTQ_STR-CLSGTASKSTATUSCHGREASONDESC sy-vline
WA_CFCCERRTSTQ_STR-CLSGTASKSTATUSISCHGDMANUALLY sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASKTYPE sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASKNAME sy-vline
WA_CFCCERRTSTQ_STR-ISCRITICALPATH sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASKPROCESSOR sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASKPROCESSORTYPE sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASKRESPONSIBLE sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASKRESPONSIBLETYPE sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGTASKGLOBALID sy-vline
WA_CFCCERRTSTQ_STR-CUSTOMDIMENSION1 sy-vline
WA_CFCCERRTSTQ_STR-CUSTOMDIMENSION2 sy-vline
WA_CFCCERRTSTQ_STR-CUSTOMDIMENSION3 sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGMILESTONE sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGPHASE sy-vline
WA_CFCCERRTSTQ_STR-KEYDATE sy-vline
WA_CFCCERRTSTQ_STR-CLOSINGAUTHORIZATIONGROUP sy-vline
WA_CFCCERRTSTQ_STR-FISCALYEAR sy-vline
WA_CFCCERRTSTQ_STR-FISCALYEARPERIOD sy-vline
WA_CFCCERRTSTQ_STR-NMBROFCMPLTDWITHERRORCLSGTASKS sy-vline
WA_CFCCERRTSTQ_STR-PLANNEDSTARTDATE sy-vline
WA_CFCCERRTSTQ_STR-PLANNEDENDDATE sy-vline
WA_CFCCERRTSTQ_STR-PLANNEDSTARTTIME sy-vline
WA_CFCCERRTSTQ_STR-PLANNEDENDTIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.