ABAP Select data from SAP table CF650 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CF650 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CF650. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CF650 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CF650 TYPE STANDARD TABLE OF CF650,
      WA_CF650 TYPE CF650,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CF650> TYPE CF650.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CF650.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CF650
  INTO TABLE IT_CF650.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CF650
*  INTO TABLE @DATA(IT_CF6502).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CF650 INDEX 1 INTO DATA(WA_CF6502).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CF650 ASSIGNING <CF650>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CF650>-MANDT = 1.
<CF650>-VERSIO = 1.
<CF650>-PLACTI = 1.
<CF650>-YEARB = 1.
<CF650>-PERDE = 1.
ENDLOOP.

LOOP AT IT_CF650 INTO WA_CF650.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CF650-BUKRS1, sy-vline,
WA_CF650-CNTRY, sy-vline,
WA_CF650-CUSTNM, sy-vline,
WA_CF650-ESPART, sy-vline,
WA_CF650-MATNR, sy-vline,
WA_CF650-BZIRK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CF650 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CF650 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CF650 INTO WA_CF650. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VERSIO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CF650-VERSIO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CF650-VERSIO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field YEARB CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_CF650-YEARB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CF650-YEARB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CUSTNM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CF650-CUSTNM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CF650-CUSTNM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CF650-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CF650-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUANT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CF650-QUANT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CF650-QUANT_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CF650_STR,
MANDT TYPE STRING,
VERSIO TYPE STRING,
PLACTI TYPE STRING,
YEARB TYPE STRING,
PERDE TYPE STRING,
BUKRS1 TYPE STRING,
CNTRY TYPE STRING,
CUSTNM TYPE STRING,
ESPART TYPE STRING,
MATNR TYPE STRING,
BZIRK TYPE STRING,
RECNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REV1 TYPE STRING,
QUANT TYPE STRING,
QUANT_UNIT TYPE STRING,
VARM1 TYPE STRING,
VARP2 TYPE STRING,
CON1 TYPE STRING,
CON2 TYPE STRING,
CON3 TYPE STRING,END OF T_EKKO_STR. DATA: WA_CF650_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CF650_STR-MANDT sy-vline
WA_CF650_STR-VERSIO sy-vline
WA_CF650_STR-PLACTI sy-vline
WA_CF650_STR-YEARB sy-vline
WA_CF650_STR-PERDE sy-vline
WA_CF650_STR-BUKRS1 sy-vline
WA_CF650_STR-CNTRY sy-vline
WA_CF650_STR-CUSTNM sy-vline
WA_CF650_STR-ESPART sy-vline
WA_CF650_STR-MATNR sy-vline
WA_CF650_STR-BZIRK sy-vline
WA_CF650_STR-RECNR sy-vline
WA_CF650_STR-AEDTM sy-vline
WA_CF650_STR-UNAME sy-vline
WA_CF650_STR-REV1 sy-vline
WA_CF650_STR-QUANT sy-vline
WA_CF650_STR-QUANT_UNIT sy-vline
WA_CF650_STR-VARM1 sy-vline
WA_CF650_STR-VARP2 sy-vline
WA_CF650_STR-CON1 sy-vline
WA_CF650_STR-CON2 sy-vline
WA_CF650_STR-CON3 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.