ABAP Select data from SAP table CEU1_2002_DYNP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CEU1_2002_DYNP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CEU1_2002_DYNP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CEU1_2002_DYNP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CEU1_2002_DYNP TYPE STANDARD TABLE OF CEU1_2002_DYNP,
      WA_CEU1_2002_DYNP TYPE CEU1_2002_DYNP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CEU1_2002_DYNP> TYPE CEU1_2002_DYNP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CEU1_2002_DYNP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CEU1_2002_DYNP
  INTO TABLE IT_CEU1_2002_DYNP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CEU1_2002_DYNP
*  INTO TABLE @DATA(IT_CEU1_2002_DYNP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CEU1_2002_DYNP INDEX 1 INTO DATA(WA_CEU1_2002_DYNP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CEU1_2002_DYNP ASSIGNING <CEU1_2002_DYNP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CEU1_2002_DYNP>-MANDT = 1.
<CEU1_2002_DYNP>-DOKAR = 1.
<CEU1_2002_DYNP>-DOKNR = 1.
<CEU1_2002_DYNP>-DOKVR = 1.
<CEU1_2002_DYNP>-DOKTL = 1.
ENDLOOP.

LOOP AT IT_CEU1_2002_DYNP INTO WA_CEU1_2002_DYNP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CEU1_2002_DYNP-DWNAM, sy-vline,
WA_CEU1_2002_DYNP-DOKST, sy-vline,
WA_CEU1_2002_DYNP-LABOR, sy-vline,
WA_CEU1_2002_DYNP-AENNR, sy-vline,
WA_CEU1_2002_DYNP-WERKA, sy-vline,
WA_CEU1_2002_DYNP-LOEDK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CEU1_2002_DYNP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CEU1_2002_DYNP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CEU1_2002_DYNP INTO WA_CEU1_2002_DYNP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DOKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CEU1_2002_DYNP-DOKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CEU1_2002_DYNP-DOKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CEU1_2002_DYNP-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CEU1_2002_DYNP-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRENR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CEU1_2002_DYNP-PRENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CEU1_2002_DYNP-PRENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOKNR_VL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CEU1_2002_DYNP-DOKNR_VL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CEU1_2002_DYNP-DOKNR_VL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOKNRT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CEU1_2002_DYNP-DOKNRT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CEU1_2002_DYNP-DOKNRT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGUT CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_CEU1_2002_DYNP-LANGUT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CEU1_2002_DYNP-LANGUT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CEU1_2002_DYNP_STR,
MANDT TYPE STRING,
DOKAR TYPE STRING,
DOKNR TYPE STRING,
DOKVR TYPE STRING,
DOKTL TYPE STRING,
DWNAM TYPE STRING,
DOKST TYPE STRING,
LABOR TYPE STRING,
AENNR TYPE STRING,
WERKA TYPE STRING,
LOEDK TYPE STRING,
CADKZ TYPE STRING,
PRENR TYPE STRING,
PREVR TYPE STRING,
PRETL TYPE STRING,
PREAR TYPE STRING,
BEGRU TYPE STRING,
FILEP TYPE STRING,
DTTRG TYPE STRING,
DAPPL TYPE STRING,
FILEP1 TYPE STRING,
DTTRG1 TYPE STRING,
DAPPL1 TYPE STRING,
VRLDAT TYPE STRING,
VPRIOR TYPE STRING,
RES1 TYPE STRING,
RES2 TYPE STRING,
RES3 TYPE STRING,
RES4 TYPE STRING,
MRK_FILEP TYPE STRING,
MRK_DTTRG TYPE STRING,
MRK_FILEP1 TYPE STRING,
MRK_DTTRG1 TYPE STRING,
ADATUM TYPE STRING,
DOKNR_VL TYPE STRING,
DOKTL_VL TYPE STRING,
DOKVR_VL TYPE STRING,
FILELEN TYPE STRING,
FILELEN1 TYPE STRING,
CM_RELEVANCE TYPE STRING,
CM_FIXED TYPE STRING,
DOCUMENT_INFO_RECORD_KEY TYPE STRING,
DUMMY_DRAW_INCL_EEW_PS TYPE STRING,
MANDTT TYPE STRING,
DOKART TYPE STRING,
DOKNRT TYPE STRING,
DOKVRT TYPE STRING,
DOKTLT TYPE STRING,
LANGUT TYPE STRING,
DKTXTT TYPE STRING,
LTXINT TYPE STRING,
DKTXT_UCT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CEU1_2002_DYNP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CEU1_2002_DYNP_STR-MANDT sy-vline
WA_CEU1_2002_DYNP_STR-DOKAR sy-vline
WA_CEU1_2002_DYNP_STR-DOKNR sy-vline
WA_CEU1_2002_DYNP_STR-DOKVR sy-vline
WA_CEU1_2002_DYNP_STR-DOKTL sy-vline
WA_CEU1_2002_DYNP_STR-DWNAM sy-vline
WA_CEU1_2002_DYNP_STR-DOKST sy-vline
WA_CEU1_2002_DYNP_STR-LABOR sy-vline
WA_CEU1_2002_DYNP_STR-AENNR sy-vline
WA_CEU1_2002_DYNP_STR-WERKA sy-vline
WA_CEU1_2002_DYNP_STR-LOEDK sy-vline
WA_CEU1_2002_DYNP_STR-CADKZ sy-vline
WA_CEU1_2002_DYNP_STR-PRENR sy-vline
WA_CEU1_2002_DYNP_STR-PREVR sy-vline
WA_CEU1_2002_DYNP_STR-PRETL sy-vline
WA_CEU1_2002_DYNP_STR-PREAR sy-vline
WA_CEU1_2002_DYNP_STR-BEGRU sy-vline
WA_CEU1_2002_DYNP_STR-FILEP sy-vline
WA_CEU1_2002_DYNP_STR-DTTRG sy-vline
WA_CEU1_2002_DYNP_STR-DAPPL sy-vline
WA_CEU1_2002_DYNP_STR-FILEP1 sy-vline
WA_CEU1_2002_DYNP_STR-DTTRG1 sy-vline
WA_CEU1_2002_DYNP_STR-DAPPL1 sy-vline
WA_CEU1_2002_DYNP_STR-VRLDAT sy-vline
WA_CEU1_2002_DYNP_STR-VPRIOR sy-vline
WA_CEU1_2002_DYNP_STR-RES1 sy-vline
WA_CEU1_2002_DYNP_STR-RES2 sy-vline
WA_CEU1_2002_DYNP_STR-RES3 sy-vline
WA_CEU1_2002_DYNP_STR-RES4 sy-vline
WA_CEU1_2002_DYNP_STR-MRK_FILEP sy-vline
WA_CEU1_2002_DYNP_STR-MRK_DTTRG sy-vline
WA_CEU1_2002_DYNP_STR-MRK_FILEP1 sy-vline
WA_CEU1_2002_DYNP_STR-MRK_DTTRG1 sy-vline
WA_CEU1_2002_DYNP_STR-ADATUM sy-vline
WA_CEU1_2002_DYNP_STR-DOKNR_VL sy-vline
WA_CEU1_2002_DYNP_STR-DOKTL_VL sy-vline
WA_CEU1_2002_DYNP_STR-DOKVR_VL sy-vline
WA_CEU1_2002_DYNP_STR-FILELEN sy-vline
WA_CEU1_2002_DYNP_STR-FILELEN1 sy-vline
WA_CEU1_2002_DYNP_STR-CM_RELEVANCE sy-vline
WA_CEU1_2002_DYNP_STR-CM_FIXED sy-vline
WA_CEU1_2002_DYNP_STR-DOCUMENT_INFO_RECORD_KEY sy-vline
WA_CEU1_2002_DYNP_STR-DUMMY_DRAW_INCL_EEW_PS sy-vline
WA_CEU1_2002_DYNP_STR-MANDTT sy-vline
WA_CEU1_2002_DYNP_STR-DOKART sy-vline
WA_CEU1_2002_DYNP_STR-DOKNRT sy-vline
WA_CEU1_2002_DYNP_STR-DOKVRT sy-vline
WA_CEU1_2002_DYNP_STR-DOKTLT sy-vline
WA_CEU1_2002_DYNP_STR-LANGUT sy-vline
WA_CEU1_2002_DYNP_STR-DKTXTT sy-vline
WA_CEU1_2002_DYNP_STR-LTXINT sy-vline
WA_CEU1_2002_DYNP_STR-DKTXT_UCT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.