ABAP Select data from SAP table CEFORMT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CEFORMT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CEFORMT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CEFORMT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CEFORMT TYPE STANDARD TABLE OF CEFORMT,
      WA_CEFORMT TYPE CEFORMT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CEFORMT> TYPE CEFORMT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CEFORMT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CEFORMT
  INTO TABLE IT_CEFORMT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CEFORMT
*  INTO TABLE @DATA(IT_CEFORMT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CEFORMT INDEX 1 INTO DATA(WA_CEFORMT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CEFORMT ASSIGNING <CEFORMT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CEFORMT>-MANDT = 1.
<CEFORMT>-SPRAS = 1.
<CEFORMT>-APPLCLASS = 1.
<CEFORMT>-SUBCLASS = 1.
<CEFORMT>-TABNAME = 1.
ENDLOOP.

LOOP AT IT_CEFORMT INTO WA_CEFORMT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CEFORMT-FORM, sy-vline,
WA_CEFORMT-SUBNR, sy-vline,
WA_CEFORMT-ELNR1, sy-vline,
WA_CEFORMT-ELNR2, sy-vline,
WA_CEFORMT-TXTKZ, sy-vline,
WA_CEFORMT-TXTMT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CEFORMT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CEFORMT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CEFORMT INTO WA_CEFORMT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_CEFORMT-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CEFORMT-SPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CEFORMT_STR,
MANDT TYPE STRING,
SPRAS TYPE STRING,
APPLCLASS TYPE STRING,
SUBCLASS TYPE STRING,
TABNAME TYPE STRING,
FORM TYPE STRING,
SUBNR TYPE STRING,
ELNR1 TYPE STRING,
ELNR2 TYPE STRING,
TXTKZ TYPE STRING,
TXTMT TYPE STRING,
TXTLG TYPE STRING,END OF T_EKKO_STR. DATA: WA_CEFORMT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CEFORMT_STR-MANDT sy-vline
WA_CEFORMT_STR-SPRAS sy-vline
WA_CEFORMT_STR-APPLCLASS sy-vline
WA_CEFORMT_STR-SUBCLASS sy-vline
WA_CEFORMT_STR-TABNAME sy-vline
WA_CEFORMT_STR-FORM sy-vline
WA_CEFORMT_STR-SUBNR sy-vline
WA_CEFORMT_STR-ELNR1 sy-vline
WA_CEFORMT_STR-ELNR2 sy-vline
WA_CEFORMT_STR-TXTKZ sy-vline
WA_CEFORMT_STR-TXTMT sy-vline
WA_CEFORMT_STR-TXTLG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.