ABAP Select data from SAP table CE9S_CP_P_IC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CE9S_CP_P_IC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CE9S_CP_P_IC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CE9S_CP_P_IC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CE9S_CP_P_IC TYPE STANDARD TABLE OF CE9S_CP_P_IC,
      WA_CE9S_CP_P_IC TYPE CE9S_CP_P_IC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CE9S_CP_P_IC> TYPE CE9S_CP_P_IC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CE9S_CP_P_IC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CE9S_CP_P_IC
  INTO TABLE IT_CE9S_CP_P_IC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CE9S_CP_P_IC
*  INTO TABLE @DATA(IT_CE9S_CP_P_IC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CE9S_CP_P_IC INDEX 1 INTO DATA(WA_CE9S_CP_P_IC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CE9S_CP_P_IC ASSIGNING <CE9S_CP_P_IC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CE9S_CP_P_IC>-MANDT = 1.
<CE9S_CP_P_IC>-BELNR = 1.
<CE9S_CP_P_IC>-POSNR = 1.
<CE9S_CP_P_IC>-SUBNR = 1.
<CE9S_CP_P_IC>-CURTP = 1.
ENDLOOP.

LOOP AT IT_CE9S_CP_P_IC INTO WA_CE9S_CP_P_IC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CE9S_CP_P_IC-KSTAR, sy-vline,
WA_CE9S_CP_P_IC-KSTARS, sy-vline,
WA_CE9S_CP_P_IC-CURRENCY, sy-vline,
WA_CE9S_CP_P_IC-VALUE, sy-vline,
WA_CE9S_CP_P_IC-VALUE_FIX, sy-vline,
WA_CE9S_CP_P_IC-ACC_BUKRS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CE9S_CP_P_IC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CE9S_CP_P_IC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CE9S_CP_P_IC INTO WA_CE9S_CP_P_IC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE9S_CP_P_IC-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE9S_CP_P_IC-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KSTAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE9S_CP_P_IC-KSTAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE9S_CP_P_IC-KSTAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KSTARS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE9S_CP_P_IC-KSTARS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE9S_CP_P_IC-KSTARS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field VALUE CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_CE9S_CP_P_IC-VALUE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE9S_CP_P_IC-VALUE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field VALUE_FIX CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_CE9S_CP_P_IC-VALUE_FIX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE9S_CP_P_IC-VALUE_FIX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACC_BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE9S_CP_P_IC-ACC_BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE9S_CP_P_IC-ACC_BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field ACC_GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_CE9S_CP_P_IC-ACC_GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE9S_CP_P_IC-ACC_GJAHR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CE9S_CP_P_IC_STR,
MANDT TYPE STRING,
BELNR TYPE STRING,
POSNR TYPE STRING,
SUBNR TYPE STRING,
CURTP TYPE STRING,
KSTAR TYPE STRING,
KSTARS TYPE STRING,
CURRENCY TYPE STRING,
VALUE TYPE STRING,
VALUE_FIX TYPE STRING,
ACC_BUKRS TYPE STRING,
ACC_BELNR TYPE STRING,
ACC_GJAHR TYPE STRING,
ACC_BUZEI TYPE STRING,END OF T_EKKO_STR. DATA: WA_CE9S_CP_P_IC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CE9S_CP_P_IC_STR-MANDT sy-vline
WA_CE9S_CP_P_IC_STR-BELNR sy-vline
WA_CE9S_CP_P_IC_STR-POSNR sy-vline
WA_CE9S_CP_P_IC_STR-SUBNR sy-vline
WA_CE9S_CP_P_IC_STR-CURTP sy-vline
WA_CE9S_CP_P_IC_STR-KSTAR sy-vline
WA_CE9S_CP_P_IC_STR-KSTARS sy-vline
WA_CE9S_CP_P_IC_STR-CURRENCY sy-vline
WA_CE9S_CP_P_IC_STR-VALUE sy-vline
WA_CE9S_CP_P_IC_STR-VALUE_FIX sy-vline
WA_CE9S_CP_P_IC_STR-ACC_BUKRS sy-vline
WA_CE9S_CP_P_IC_STR-ACC_BELNR sy-vline
WA_CE9S_CP_P_IC_STR-ACC_GJAHR sy-vline
WA_CE9S_CP_P_IC_STR-ACC_BUZEI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.