ABAP Select data from SAP table CE7DYNA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CE7DYNA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CE7DYNA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CE7DYNA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CE7DYNA TYPE STANDARD TABLE OF CE7DYNA,
      WA_CE7DYNA TYPE CE7DYNA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CE7DYNA> TYPE CE7DYNA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CE7DYNA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CE7DYNA
  INTO TABLE IT_CE7DYNA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CE7DYNA
*  INTO TABLE @DATA(IT_CE7DYNA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CE7DYNA INDEX 1 INTO DATA(WA_CE7DYNA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CE7DYNA ASSIGNING <CE7DYNA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CE7DYNA>-MANDT = 1.
<CE7DYNA>-PALEDGER = 1.
<CE7DYNA>-ERKRS = 1.
<CE7DYNA>-VRGAR = 1.
<CE7DYNA>-PLIKZ = 1.
ENDLOOP.

LOOP AT IT_CE7DYNA INTO WA_CE7DYNA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CE7DYNA-VERSI, sy-vline,
WA_CE7DYNA-GJAHR, sy-vline,
WA_CE7DYNA-FIELDNAME, sy-vline,
WA_CE7DYNA-KNDNR, sy-vline,
WA_CE7DYNA-ARTNR, sy-vline,
WA_CE7DYNA-FKART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CE7DYNA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CE7DYNA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CE7DYNA INTO WA_CE7DYNA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit LEDBO, internal->external for field PALEDGER CALL FUNCTION 'CONVERSION_EXIT_LEDBO_OUTPUT' EXPORTING input = WA_CE7DYNA-PALEDGER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-PALEDGER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-VERSI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-VERSI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_CE7DYNA-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KNDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-KNDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-KNDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ARTNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CE7DYNA-ARTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-ARTNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSF CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_CE7DYNA-KURSF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-KURSF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KAUFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-KAUFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-KAUFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RKAUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-RKAUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-RKAUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_CE7DYNA-PSPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-PSPNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field COPA_POSID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_CE7DYNA-COPA_POSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-COPA_POSID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field COPA_CRMID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_CE7DYNA-COPA_CRMID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-COPA_CRMID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LEDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-LEDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-LEDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WRTTP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-WRTTP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-WRTTP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KSTAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-KSTAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-KSTAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BEKNZ, internal->external for field BEKNZ CALL FUNCTION 'CONVERSION_EXIT_BEKNZ_OUTPUT' EXPORTING input = WA_CE7DYNA-BEKNZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-BEKNZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRZNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-PRZNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-PRZNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE7DYNA-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-MEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-RECID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-RECID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ETYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-ETYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-ETYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field S_PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-S_PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-S_PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PPRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-PPRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-PPRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SCOPE, internal->external for field SCOPE CALL FUNCTION 'CONVERSION_EXIT_SCOPE_OUTPUT' EXPORTING input = WA_CE7DYNA-SCOPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-SCOPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-LOGSYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-LOGSYSTEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TARKZ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-TARKZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-TARKZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKSTA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-VKSTA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-VKSTA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TARKZ_I CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-TARKZ_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-TARKZ_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field AUSEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE7DYNA-AUSEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-AUSEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE7DYNA-LEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-LEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ERZUO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-ERZUO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-ERZUO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNWE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-KUNWE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-KUNWE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HIE01 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-HIE01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-HIE01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HIE02 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-HIE02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-HIE02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HIE03 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-HIE03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-HIE03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WWPRO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-WWPRO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-WWPRO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WWSDL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-WWSDL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-WWSDL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field CRMELEM CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_CE7DYNA-CRMELEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-CRMELEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CRMCSTY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE7DYNA-CRMCSTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE7DYNA-CRMCSTY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CE7DYNA_STR,
MANDT TYPE STRING,
PALEDGER TYPE STRING,
ERKRS TYPE STRING,
VRGAR TYPE STRING,
PLIKZ TYPE STRING,
VERSI TYPE STRING,
GJAHR TYPE STRING,
FIELDNAME TYPE STRING,
KNDNR TYPE STRING,
ARTNR TYPE STRING,
FKART TYPE STRING,
WAERS TYPE STRING,
PERIV TYPE STRING,
PERFLAG2 TYPE STRING,
FRWAE TYPE STRING,
KURSF TYPE STRING,
KURST TYPE STRING,
ABLEDA TYPE STRING,
KAUFN TYPE STRING,
KDPOS TYPE STRING,
RKAUFNR TYPE STRING,
BUKRS TYPE STRING,
S_BUKRS TYPE STRING,
KOKRS TYPE STRING,
WERKS TYPE STRING,
GSBER TYPE STRING,
S_GSBER TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
KSTRG TYPE STRING,
PSPNR TYPE STRING,
COPA_POSID TYPE STRING,
COPA_CRMID TYPE STRING,
PA_TYPE TYPE STRING,
LEDNR TYPE STRING,
OBJNR TYPE STRING,
WRTTP TYPE STRING,
VERSN TYPE STRING,
KSTAR TYPE STRING,
VRGNG TYPE STRING,
PAROB TYPE STRING,
USPOB TYPE STRING,
BEKNZ TYPE STRING,
TWAER TYPE STRING,
BUPER TYPE STRING,
KOSTL TYPE STRING,
LSTAR TYPE STRING,
PRZNR TYPE STRING,
OWAER TYPE STRING,
KWAER TYPE STRING,
MEINH TYPE STRING,
KTOPL TYPE STRING,
LMONA TYPE STRING,
INUMKR TYPE STRING,
SETKIND TYPE STRING,
BUDAT TYPE STRING,
VNAME TYPE STRING,
RECID TYPE STRING,
ETYPE TYPE STRING,
PRCTR TYPE STRING,
S_PRCTR TYPE STRING,
PPRCTR TYPE STRING,
AUTYP TYPE STRING,
SCOPE TYPE STRING,
LOGSYSTEM TYPE STRING,
TARKZ TYPE STRING,
VKSTA TYPE STRING,
YRATE TYPE STRING,
FIXVO TYPE STRING,
TARKZ_I TYPE STRING,
MANIST TYPE STRING,
AUSFK TYPE STRING,
AUSEH TYPE STRING,
LEINH TYPE STRING,
ERZUO TYPE STRING,
MATKL TYPE STRING,
MVGR1 TYPE STRING,
WWPH1 TYPE STRING,
WWPH2 TYPE STRING,
WWPH3 TYPE STRING,
WWPRC TYPE STRING,
WWSOP TYPE STRING,
WWSBU TYPE STRING,
KDGRP TYPE STRING,
KUKLA TYPE STRING,
BZIRK TYPE STRING,
BRSCH TYPE STRING,
WWREG TYPE STRING,
LAND1 TYPE STRING,
KUNWE TYPE STRING,
WWCST TYPE STRING,
WWRST TYPE STRING,
HIE01 TYPE STRING,
HIE02 TYPE STRING,
HIE03 TYPE STRING,
VRTNR TYPE STRING,
VKBUR TYPE STRING,
VKGRP TYPE STRING,
WWICI TYPE STRING,
AUGRU TYPE STRING,
WWPRO TYPE STRING,
WWSDL TYPE STRING,
PAPH1 TYPE STRING,
PAPH2 TYPE STRING,
PAPH3 TYPE STRING,
PAREG TYPE STRING,
SORHIST TYPE STRING,
WWMEA TYPE STRING,
WWQUA TYPE STRING,
WWSUR TYPE STRING,
CRMELEM TYPE STRING,
CRMCSTY TYPE STRING,
ROUTE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CE7DYNA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CE7DYNA_STR-MANDT sy-vline
WA_CE7DYNA_STR-PALEDGER sy-vline
WA_CE7DYNA_STR-ERKRS sy-vline
WA_CE7DYNA_STR-VRGAR sy-vline
WA_CE7DYNA_STR-PLIKZ sy-vline
WA_CE7DYNA_STR-VERSI sy-vline
WA_CE7DYNA_STR-GJAHR sy-vline
WA_CE7DYNA_STR-FIELDNAME sy-vline
WA_CE7DYNA_STR-KNDNR sy-vline
WA_CE7DYNA_STR-ARTNR sy-vline
WA_CE7DYNA_STR-FKART sy-vline
WA_CE7DYNA_STR-WAERS sy-vline
WA_CE7DYNA_STR-PERIV sy-vline
WA_CE7DYNA_STR-PERFLAG2 sy-vline
WA_CE7DYNA_STR-FRWAE sy-vline
WA_CE7DYNA_STR-KURSF sy-vline
WA_CE7DYNA_STR-KURST sy-vline
WA_CE7DYNA_STR-ABLEDA sy-vline
WA_CE7DYNA_STR-KAUFN sy-vline
WA_CE7DYNA_STR-KDPOS sy-vline
WA_CE7DYNA_STR-RKAUFNR sy-vline
WA_CE7DYNA_STR-BUKRS sy-vline
WA_CE7DYNA_STR-S_BUKRS sy-vline
WA_CE7DYNA_STR-KOKRS sy-vline
WA_CE7DYNA_STR-WERKS sy-vline
WA_CE7DYNA_STR-GSBER sy-vline
WA_CE7DYNA_STR-S_GSBER sy-vline
WA_CE7DYNA_STR-VKORG sy-vline
WA_CE7DYNA_STR-VTWEG sy-vline
WA_CE7DYNA_STR-SPART sy-vline
WA_CE7DYNA_STR-KSTRG sy-vline
WA_CE7DYNA_STR-PSPNR sy-vline
WA_CE7DYNA_STR-COPA_POSID sy-vline
WA_CE7DYNA_STR-COPA_CRMID sy-vline
WA_CE7DYNA_STR-PA_TYPE sy-vline
WA_CE7DYNA_STR-LEDNR sy-vline
WA_CE7DYNA_STR-OBJNR sy-vline
WA_CE7DYNA_STR-WRTTP sy-vline
WA_CE7DYNA_STR-VERSN sy-vline
WA_CE7DYNA_STR-KSTAR sy-vline
WA_CE7DYNA_STR-VRGNG sy-vline
WA_CE7DYNA_STR-PAROB sy-vline
WA_CE7DYNA_STR-USPOB sy-vline
WA_CE7DYNA_STR-BEKNZ sy-vline
WA_CE7DYNA_STR-TWAER sy-vline
WA_CE7DYNA_STR-BUPER sy-vline
WA_CE7DYNA_STR-KOSTL sy-vline
WA_CE7DYNA_STR-LSTAR sy-vline
WA_CE7DYNA_STR-PRZNR sy-vline
WA_CE7DYNA_STR-OWAER sy-vline
WA_CE7DYNA_STR-KWAER sy-vline
WA_CE7DYNA_STR-MEINH sy-vline
WA_CE7DYNA_STR-KTOPL sy-vline
WA_CE7DYNA_STR-LMONA sy-vline
WA_CE7DYNA_STR-INUMKR sy-vline
WA_CE7DYNA_STR-SETKIND sy-vline
WA_CE7DYNA_STR-BUDAT sy-vline
WA_CE7DYNA_STR-VNAME sy-vline
WA_CE7DYNA_STR-RECID sy-vline
WA_CE7DYNA_STR-ETYPE sy-vline
WA_CE7DYNA_STR-PRCTR sy-vline
WA_CE7DYNA_STR-S_PRCTR sy-vline
WA_CE7DYNA_STR-PPRCTR sy-vline
WA_CE7DYNA_STR-AUTYP sy-vline
WA_CE7DYNA_STR-SCOPE sy-vline
WA_CE7DYNA_STR-LOGSYSTEM sy-vline
WA_CE7DYNA_STR-TARKZ sy-vline
WA_CE7DYNA_STR-VKSTA sy-vline
WA_CE7DYNA_STR-YRATE sy-vline
WA_CE7DYNA_STR-FIXVO sy-vline
WA_CE7DYNA_STR-TARKZ_I sy-vline
WA_CE7DYNA_STR-MANIST sy-vline
WA_CE7DYNA_STR-AUSFK sy-vline
WA_CE7DYNA_STR-AUSEH sy-vline
WA_CE7DYNA_STR-LEINH sy-vline
WA_CE7DYNA_STR-ERZUO sy-vline
WA_CE7DYNA_STR-MATKL sy-vline
WA_CE7DYNA_STR-MVGR1 sy-vline
WA_CE7DYNA_STR-WWPH1 sy-vline
WA_CE7DYNA_STR-WWPH2 sy-vline
WA_CE7DYNA_STR-WWPH3 sy-vline
WA_CE7DYNA_STR-WWPRC sy-vline
WA_CE7DYNA_STR-WWSOP sy-vline
WA_CE7DYNA_STR-WWSBU sy-vline
WA_CE7DYNA_STR-KDGRP sy-vline
WA_CE7DYNA_STR-KUKLA sy-vline
WA_CE7DYNA_STR-BZIRK sy-vline
WA_CE7DYNA_STR-BRSCH sy-vline
WA_CE7DYNA_STR-WWREG sy-vline
WA_CE7DYNA_STR-LAND1 sy-vline
WA_CE7DYNA_STR-KUNWE sy-vline
WA_CE7DYNA_STR-WWCST sy-vline
WA_CE7DYNA_STR-WWRST sy-vline
WA_CE7DYNA_STR-HIE01 sy-vline
WA_CE7DYNA_STR-HIE02 sy-vline
WA_CE7DYNA_STR-HIE03 sy-vline
WA_CE7DYNA_STR-VRTNR sy-vline
WA_CE7DYNA_STR-VKBUR sy-vline
WA_CE7DYNA_STR-VKGRP sy-vline
WA_CE7DYNA_STR-WWICI sy-vline
WA_CE7DYNA_STR-AUGRU sy-vline
WA_CE7DYNA_STR-WWPRO sy-vline
WA_CE7DYNA_STR-WWSDL sy-vline
WA_CE7DYNA_STR-PAPH1 sy-vline
WA_CE7DYNA_STR-PAPH2 sy-vline
WA_CE7DYNA_STR-PAPH3 sy-vline
WA_CE7DYNA_STR-PAREG sy-vline
WA_CE7DYNA_STR-SORHIST sy-vline
WA_CE7DYNA_STR-WWMEA sy-vline
WA_CE7DYNA_STR-WWQUA sy-vline
WA_CE7DYNA_STR-WWSUR sy-vline
WA_CE7DYNA_STR-CRMELEM sy-vline
WA_CE7DYNA_STR-CRMCSTY sy-vline
WA_CE7DYNA_STR-ROUTE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.