ABAP Select data from SAP table CE53301 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CE53301 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CE53301. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CE53301 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CE53301 TYPE STANDARD TABLE OF CE53301,
      WA_CE53301 TYPE CE53301,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CE53301> TYPE CE53301.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CE53301.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CE53301
  INTO TABLE IT_CE53301.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CE53301
*  INTO TABLE @DATA(IT_CE533012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CE53301 INDEX 1 INTO DATA(WA_CE533012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CE53301 ASSIGNING <CE53301>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CE53301>-MANDT = 1.
<CE53301>-PALEDGER = 1.
<CE53301>-VRGAR = 1.
<CE53301>-PLIKZ = 1.
<CE53301>-VERSI = 1.
ENDLOOP.

LOOP AT IT_CE53301 INTO WA_CE53301.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CE53301-HRKFT, sy-vline,
WA_CE53301-PAOBJNR, sy-vline,
WA_CE53301-PASUBNR, sy-vline,
WA_CE53301-PERIO, sy-vline,
WA_CE53301-ALTPERIO, sy-vline,
WA_CE53301-WTGBTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CE53301 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CE53301 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CE53301 INTO WA_CE53301. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit LEDBO, internal->external for field PALEDGER CALL FUNCTION 'CONVERSION_EXIT_LEDBO_OUTPUT' EXPORTING input = WA_CE53301-PALEDGER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE53301-PALEDGER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE53301-VERSI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE53301-VERSI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field PERIO CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_CE53301-PERIO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE53301-PERIO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field ALTPERIO CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_CE53301-ALTPERIO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE53301-ALTPERIO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WTGBTR CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_CE53301-WTGBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE53301-WTGBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WOGBTR CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_CE53301-WOGBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE53301-WOGBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WKGBTR CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_CE53301-WKGBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE53301-WKGBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WKFBTR CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_CE53301-WKFBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE53301-WKFBTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CE53301_STR,
MANDT TYPE STRING,
PALEDGER TYPE STRING,
VRGAR TYPE STRING,
PLIKZ TYPE STRING,
VERSI TYPE STRING,
HRKFT TYPE STRING,
PAOBJNR TYPE STRING,
PASUBNR TYPE STRING,
PERIO TYPE STRING,
ALTPERIO TYPE STRING,
WTGBTR TYPE STRING,
WOGBTR TYPE STRING,
WKGBTR TYPE STRING,
WKFBTR TYPE STRING,
MEGBTR TYPE STRING,
VVF01 TYPE STRING,
VVF02 TYPE STRING,
VVF03 TYPE STRING,
VVF04 TYPE STRING,
VVF05 TYPE STRING,
VVF06 TYPE STRING,
VVF07 TYPE STRING,
VVF08 TYPE STRING,
VVF09 TYPE STRING,
VVF10 TYPE STRING,
VVFOQ TYPE STRING,
VVFSQ TYPE STRING,END OF T_EKKO_STR. DATA: WA_CE53301_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CE53301_STR-MANDT sy-vline
WA_CE53301_STR-PALEDGER sy-vline
WA_CE53301_STR-VRGAR sy-vline
WA_CE53301_STR-PLIKZ sy-vline
WA_CE53301_STR-VERSI sy-vline
WA_CE53301_STR-HRKFT sy-vline
WA_CE53301_STR-PAOBJNR sy-vline
WA_CE53301_STR-PASUBNR sy-vline
WA_CE53301_STR-PERIO sy-vline
WA_CE53301_STR-ALTPERIO sy-vline
WA_CE53301_STR-WTGBTR sy-vline
WA_CE53301_STR-WOGBTR sy-vline
WA_CE53301_STR-WKGBTR sy-vline
WA_CE53301_STR-WKFBTR sy-vline
WA_CE53301_STR-MEGBTR sy-vline
WA_CE53301_STR-VVF01 sy-vline
WA_CE53301_STR-VVF02 sy-vline
WA_CE53301_STR-VVF03 sy-vline
WA_CE53301_STR-VVF04 sy-vline
WA_CE53301_STR-VVF05 sy-vline
WA_CE53301_STR-VVF06 sy-vline
WA_CE53301_STR-VVF07 sy-vline
WA_CE53301_STR-VVF08 sy-vline
WA_CE53301_STR-VVF09 sy-vline
WA_CE53301_STR-VVF10 sy-vline
WA_CE53301_STR-VVFOQ sy-vline
WA_CE53301_STR-VVFSQ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.