ABAP Select data from SAP table CE4ECC6_FLAG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CE4ECC6_FLAG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CE4ECC6_FLAG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CE4ECC6_FLAG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CE4ECC6_FLAG TYPE STANDARD TABLE OF CE4ECC6_FLAG,
      WA_CE4ECC6_FLAG TYPE CE4ECC6_FLAG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CE4ECC6_FLAG> TYPE CE4ECC6_FLAG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CE4ECC6_FLAG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CE4ECC6_FLAG
  INTO TABLE IT_CE4ECC6_FLAG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CE4ECC6_FLAG
*  INTO TABLE @DATA(IT_CE4ECC6_FLAG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CE4ECC6_FLAG INDEX 1 INTO DATA(WA_CE4ECC6_FLAG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CE4ECC6_FLAG ASSIGNING <CE4ECC6_FLAG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CE4ECC6_FLAG>-MANDT = 1.
<CE4ECC6_FLAG>-AKTBO = 1.
<CE4ECC6_FLAG>-PAOBJNR = 1.
<CE4ECC6_FLAG>-PASUBNR = 1.
<CE4ECC6_FLAG>-KNDNR = 1.
ENDLOOP.

LOOP AT IT_CE4ECC6_FLAG INTO WA_CE4ECC6_FLAG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CE4ECC6_FLAG-ARTNR, sy-vline,
WA_CE4ECC6_FLAG-FKART, sy-vline,
WA_CE4ECC6_FLAG-KAUFN, sy-vline,
WA_CE4ECC6_FLAG-KDPOS, sy-vline,
WA_CE4ECC6_FLAG-AUFNR, sy-vline,
WA_CE4ECC6_FLAG-BUKRS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CE4ECC6_FLAG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CE4ECC6_FLAG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CE4ECC6_FLAG INTO WA_CE4ECC6_FLAG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CE4ECC6_FLAG_STR,
MANDT TYPE STRING,
AKTBO TYPE STRING,
PAOBJNR TYPE STRING,
PASUBNR TYPE STRING,
KNDNR TYPE STRING,
ARTNR TYPE STRING,
FKART TYPE STRING,
KAUFN TYPE STRING,
KDPOS TYPE STRING,
AUFNR TYPE STRING,
BUKRS TYPE STRING,
KOKRS TYPE STRING,
WERKS TYPE STRING,
GSBER TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
PRCTR TYPE STRING,
PPRCTR TYPE STRING,
KSTRG TYPE STRING,
PSPNR TYPE STRING,
MEINH TYPE STRING,
BRSCH TYPE STRING,
BZIRK TYPE STRING,
KDGRP TYPE STRING,
KMVKBU TYPE STRING,
KMVTNR TYPE STRING,
MATKL TYPE STRING,
VKGRP TYPE STRING,
KMWNHG TYPE STRING,
KWSVME_ME TYPE STRING,END OF T_EKKO_STR. DATA: WA_CE4ECC6_FLAG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CE4ECC6_FLAG_STR-MANDT sy-vline
WA_CE4ECC6_FLAG_STR-AKTBO sy-vline
WA_CE4ECC6_FLAG_STR-PAOBJNR sy-vline
WA_CE4ECC6_FLAG_STR-PASUBNR sy-vline
WA_CE4ECC6_FLAG_STR-KNDNR sy-vline
WA_CE4ECC6_FLAG_STR-ARTNR sy-vline
WA_CE4ECC6_FLAG_STR-FKART sy-vline
WA_CE4ECC6_FLAG_STR-KAUFN sy-vline
WA_CE4ECC6_FLAG_STR-KDPOS sy-vline
WA_CE4ECC6_FLAG_STR-AUFNR sy-vline
WA_CE4ECC6_FLAG_STR-BUKRS sy-vline
WA_CE4ECC6_FLAG_STR-KOKRS sy-vline
WA_CE4ECC6_FLAG_STR-WERKS sy-vline
WA_CE4ECC6_FLAG_STR-GSBER sy-vline
WA_CE4ECC6_FLAG_STR-VKORG sy-vline
WA_CE4ECC6_FLAG_STR-VTWEG sy-vline
WA_CE4ECC6_FLAG_STR-SPART sy-vline
WA_CE4ECC6_FLAG_STR-PRCTR sy-vline
WA_CE4ECC6_FLAG_STR-PPRCTR sy-vline
WA_CE4ECC6_FLAG_STR-KSTRG sy-vline
WA_CE4ECC6_FLAG_STR-PSPNR sy-vline
WA_CE4ECC6_FLAG_STR-MEINH sy-vline
WA_CE4ECC6_FLAG_STR-BRSCH sy-vline
WA_CE4ECC6_FLAG_STR-BZIRK sy-vline
WA_CE4ECC6_FLAG_STR-KDGRP sy-vline
WA_CE4ECC6_FLAG_STR-KMVKBU sy-vline
WA_CE4ECC6_FLAG_STR-KMVTNR sy-vline
WA_CE4ECC6_FLAG_STR-MATKL sy-vline
WA_CE4ECC6_FLAG_STR-VKGRP sy-vline
WA_CE4ECC6_FLAG_STR-KMWNHG sy-vline
WA_CE4ECC6_FLAG_STR-KWSVME_ME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.