ABAP Select data from SAP table CE3OC01 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CE3OC01 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CE3OC01. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CE3OC01 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CE3OC01 TYPE STANDARD TABLE OF CE3OC01,
      WA_CE3OC01 TYPE CE3OC01,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CE3OC01> TYPE CE3OC01.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CE3OC01.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CE3OC01
  INTO TABLE IT_CE3OC01.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CE3OC01
*  INTO TABLE @DATA(IT_CE3OC012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CE3OC01 INDEX 1 INTO DATA(WA_CE3OC012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CE3OC01 ASSIGNING <CE3OC01>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CE3OC01>-MANDT = 1.
<CE3OC01>-PAOBJNR = 1.
<CE3OC01>-PALEDGER = 1.
<CE3OC01>-VRGAR = 1.
<CE3OC01>-PLIKZ = 1.
ENDLOOP.

LOOP AT IT_CE3OC01 INTO WA_CE3OC01.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CE3OC01-VERSI, sy-vline,
WA_CE3OC01-PERBL, sy-vline,
WA_CE3OC01-PASUBNR, sy-vline,
WA_CE3OC01-PAPAOBJNR, sy-vline,
WA_CE3OC01-PAPASUBNR, sy-vline,
WA_CE3OC01-HRKFT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CE3OC01 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CE3OC01 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CE3OC01 INTO WA_CE3OC01. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit LEDBO, internal->external for field PALEDGER CALL FUNCTION 'CONVERSION_EXIT_LEDBO_OUTPUT' EXPORTING input = WA_CE3OC01-PALEDGER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE3OC01-PALEDGER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE3OC01-VERSI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE3OC01-VERSI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field PERBL CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_CE3OC01-PERBL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE3OC01-PERBL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_CE3OC01-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE3OC01-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field ERLOS001 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_CE3OC01-ERLOS001 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE3OC01-ERLOS001.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CE3OC01_STR,
MANDT TYPE STRING,
PAOBJNR TYPE STRING,
PALEDGER TYPE STRING,
VRGAR TYPE STRING,
PLIKZ TYPE STRING,
VERSI TYPE STRING,
PERBL TYPE STRING,
PASUBNR TYPE STRING,
PAPAOBJNR TYPE STRING,
PAPASUBNR TYPE STRING,
HRKFT TYPE STRING,
UPDAT TYPE STRING,
USNAM TYPE STRING,
GJAHR TYPE STRING,
REC_WAERS TYPE STRING,
TIMESTMP TYPE STRING,
ABSMG001 TYPE STRING,
ERLOS001 TYPE STRING,
VV020001 TYPE STRING,
VV030001 TYPE STRING,
VV040001 TYPE STRING,
VV060001 TYPE STRING,
VV070001 TYPE STRING,
VV140001 TYPE STRING,
VV190001 TYPE STRING,
VV250001 TYPE STRING,
VV260001 TYPE STRING,
VV270001 TYPE STRING,
VV290001 TYPE STRING,
VV300001 TYPE STRING,
VV310001 TYPE STRING,
VV320001 TYPE STRING,
VV330001 TYPE STRING,
VV340001 TYPE STRING,
VV350001 TYPE STRING,
VV360001 TYPE STRING,
VV400001 TYPE STRING,
VV510001 TYPE STRING,
VV701001 TYPE STRING,
VVGRW001 TYPE STRING,
VVIQT001 TYPE STRING,
VVOQT001 TYPE STRING,END OF T_EKKO_STR. DATA: WA_CE3OC01_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CE3OC01_STR-MANDT sy-vline
WA_CE3OC01_STR-PAOBJNR sy-vline
WA_CE3OC01_STR-PALEDGER sy-vline
WA_CE3OC01_STR-VRGAR sy-vline
WA_CE3OC01_STR-PLIKZ sy-vline
WA_CE3OC01_STR-VERSI sy-vline
WA_CE3OC01_STR-PERBL sy-vline
WA_CE3OC01_STR-PASUBNR sy-vline
WA_CE3OC01_STR-PAPAOBJNR sy-vline
WA_CE3OC01_STR-PAPASUBNR sy-vline
WA_CE3OC01_STR-HRKFT sy-vline
WA_CE3OC01_STR-UPDAT sy-vline
WA_CE3OC01_STR-USNAM sy-vline
WA_CE3OC01_STR-GJAHR sy-vline
WA_CE3OC01_STR-REC_WAERS sy-vline
WA_CE3OC01_STR-TIMESTMP sy-vline
WA_CE3OC01_STR-ABSMG001 sy-vline
WA_CE3OC01_STR-ERLOS001 sy-vline
WA_CE3OC01_STR-VV020001 sy-vline
WA_CE3OC01_STR-VV030001 sy-vline
WA_CE3OC01_STR-VV040001 sy-vline
WA_CE3OC01_STR-VV060001 sy-vline
WA_CE3OC01_STR-VV070001 sy-vline
WA_CE3OC01_STR-VV140001 sy-vline
WA_CE3OC01_STR-VV190001 sy-vline
WA_CE3OC01_STR-VV250001 sy-vline
WA_CE3OC01_STR-VV260001 sy-vline
WA_CE3OC01_STR-VV270001 sy-vline
WA_CE3OC01_STR-VV290001 sy-vline
WA_CE3OC01_STR-VV300001 sy-vline
WA_CE3OC01_STR-VV310001 sy-vline
WA_CE3OC01_STR-VV320001 sy-vline
WA_CE3OC01_STR-VV330001 sy-vline
WA_CE3OC01_STR-VV340001 sy-vline
WA_CE3OC01_STR-VV350001 sy-vline
WA_CE3OC01_STR-VV360001 sy-vline
WA_CE3OC01_STR-VV400001 sy-vline
WA_CE3OC01_STR-VV510001 sy-vline
WA_CE3OC01_STR-VV701001 sy-vline
WA_CE3OC01_STR-VVGRW001 sy-vline
WA_CE3OC01_STR-VVIQT001 sy-vline
WA_CE3OC01_STR-VVOQT001 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.