ABAP Select data from SAP table CE1R300 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CE1R300 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CE1R300. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CE1R300 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CE1R300 TYPE STANDARD TABLE OF CE1R300,
      WA_CE1R300 TYPE CE1R300,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CE1R300> TYPE CE1R300.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CE1R300.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CE1R300
  INTO TABLE IT_CE1R300.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CE1R300
*  INTO TABLE @DATA(IT_CE1R3002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CE1R300 INDEX 1 INTO DATA(WA_CE1R3002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CE1R300 ASSIGNING <CE1R300>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CE1R300>-MANDT = 1.
<CE1R300>-PALEDGER = 1.
<CE1R300>-VRGAR = 1.
<CE1R300>-VERSI = 1.
<CE1R300>-PERIO = 1.
ENDLOOP.

LOOP AT IT_CE1R300 INTO WA_CE1R300.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CE1R300-PAOBJNR, sy-vline,
WA_CE1R300-PASUBNR, sy-vline,
WA_CE1R300-BELNR, sy-vline,
WA_CE1R300-POSNR, sy-vline,
WA_CE1R300-HZDAT, sy-vline,
WA_CE1R300-USNAM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CE1R300 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CE1R300 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CE1R300 INTO WA_CE1R300. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit LEDBO, internal->external for field PALEDGER CALL FUNCTION 'CONVERSION_EXIT_LEDBO_OUTPUT' EXPORTING input = WA_CE1R300-PALEDGER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-PALEDGER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-VERSI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-VERSI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field PERIO CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_CE1R300-PERIO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-PERIO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_CE1R300-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field ALTPERIO CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_CE1R300-ALTPERIO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-ALTPERIO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KNDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-KNDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-KNDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ARTNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CE1R300-ARTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-ARTNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSF CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_CE1R300-KURSF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-KURSF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSBK CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_CE1R300-KURSBK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-KURSBK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSKZ CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_CE1R300-KURSKZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-KURSKZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KAUFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-KAUFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-KAUFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RKAUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-RKAUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-RKAUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SKOST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-SKOST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-SKOST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRZNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-PRZNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-PRZNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KSTAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-KSTAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-KSTAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_CE1R300-PSPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-PSPNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-RBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-RBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STO_BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-STO_BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-STO_BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PPRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-PPRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-PPRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COPA_AWSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1R300-COPA_AWSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-COPA_AWSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VV700_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1R300-VV700_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1R300-VV700_ME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CE1R300_STR,
MANDT TYPE STRING,
PALEDGER TYPE STRING,
VRGAR TYPE STRING,
VERSI TYPE STRING,
PERIO TYPE STRING,
PAOBJNR TYPE STRING,
PASUBNR TYPE STRING,
BELNR TYPE STRING,
POSNR TYPE STRING,
HZDAT TYPE STRING,
USNAM TYPE STRING,
GJAHR TYPE STRING,
PERDE TYPE STRING,
WADAT TYPE STRING,
FADAT TYPE STRING,
BUDAT TYPE STRING,
ALTPERIO TYPE STRING,
PAPAOBJNR TYPE STRING,
PAPASUBNR TYPE STRING,
KNDNR TYPE STRING,
ARTNR TYPE STRING,
FKART TYPE STRING,
FRWAE TYPE STRING,
KURSF TYPE STRING,
KURSBK TYPE STRING,
KURSKZ TYPE STRING,
REC_WAERS TYPE STRING,
KAUFN TYPE STRING,
KDPOS TYPE STRING,
RKAUFNR TYPE STRING,
SKOST TYPE STRING,
PRZNR TYPE STRING,
BUKRS TYPE STRING,
KOKRS TYPE STRING,
WERKS TYPE STRING,
GSBER TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
HRKFT TYPE STRING,
PLIKZ TYPE STRING,
KSTAR TYPE STRING,
PSPNR TYPE STRING,
KSTRG TYPE STRING,
RBELN TYPE STRING,
RPOSN TYPE STRING,
STO_BELNR TYPE STRING,
STO_POSNR TYPE STRING,
PRCTR TYPE STRING,
PPRCTR TYPE STRING,
RKESTATU TYPE STRING,
TIMESTMP TYPE STRING,
COPA_AWTYP TYPE STRING,
COPA_AWORG TYPE STRING,
COPA_BWZPT TYPE STRING,
COPA_AWSYS TYPE STRING,
ABTNR TYPE STRING,
EKORG TYPE STRING,
MATKL TYPE STRING,
WGRU1 TYPE STRING,
WGRU2 TYPE STRING,
VV700_ME TYPE STRING,
VV700 TYPE STRING,
VV701 TYPE STRING,
VV702 TYPE STRING,
VV707 TYPE STRING,
VV708 TYPE STRING,
VV709 TYPE STRING,
VV710 TYPE STRING,
VV711 TYPE STRING,
VV712 TYPE STRING,
VV713 TYPE STRING,
VV714 TYPE STRING,
VV715 TYPE STRING,
VV716 TYPE STRING,
VV717 TYPE STRING,
VV718 TYPE STRING,
VV719 TYPE STRING,
VV720 TYPE STRING,
VV721 TYPE STRING,
VV722 TYPE STRING,
VV723 TYPE STRING,
VV724 TYPE STRING,
VV725 TYPE STRING,
VV726 TYPE STRING,
VV699 TYPE STRING,
VV680 TYPE STRING,
VV681 TYPE STRING,
VV692 TYPE STRING,
VV694 TYPE STRING,
VV695 TYPE STRING,
VV696 TYPE STRING,
VV697 TYPE STRING,
VV698 TYPE STRING,
VV690 TYPE STRING,
VV693 TYPE STRING,END OF T_EKKO_STR. DATA: WA_CE1R300_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CE1R300_STR-MANDT sy-vline
WA_CE1R300_STR-PALEDGER sy-vline
WA_CE1R300_STR-VRGAR sy-vline
WA_CE1R300_STR-VERSI sy-vline
WA_CE1R300_STR-PERIO sy-vline
WA_CE1R300_STR-PAOBJNR sy-vline
WA_CE1R300_STR-PASUBNR sy-vline
WA_CE1R300_STR-BELNR sy-vline
WA_CE1R300_STR-POSNR sy-vline
WA_CE1R300_STR-HZDAT sy-vline
WA_CE1R300_STR-USNAM sy-vline
WA_CE1R300_STR-GJAHR sy-vline
WA_CE1R300_STR-PERDE sy-vline
WA_CE1R300_STR-WADAT sy-vline
WA_CE1R300_STR-FADAT sy-vline
WA_CE1R300_STR-BUDAT sy-vline
WA_CE1R300_STR-ALTPERIO sy-vline
WA_CE1R300_STR-PAPAOBJNR sy-vline
WA_CE1R300_STR-PAPASUBNR sy-vline
WA_CE1R300_STR-KNDNR sy-vline
WA_CE1R300_STR-ARTNR sy-vline
WA_CE1R300_STR-FKART sy-vline
WA_CE1R300_STR-FRWAE sy-vline
WA_CE1R300_STR-KURSF sy-vline
WA_CE1R300_STR-KURSBK sy-vline
WA_CE1R300_STR-KURSKZ sy-vline
WA_CE1R300_STR-REC_WAERS sy-vline
WA_CE1R300_STR-KAUFN sy-vline
WA_CE1R300_STR-KDPOS sy-vline
WA_CE1R300_STR-RKAUFNR sy-vline
WA_CE1R300_STR-SKOST sy-vline
WA_CE1R300_STR-PRZNR sy-vline
WA_CE1R300_STR-BUKRS sy-vline
WA_CE1R300_STR-KOKRS sy-vline
WA_CE1R300_STR-WERKS sy-vline
WA_CE1R300_STR-GSBER sy-vline
WA_CE1R300_STR-VKORG sy-vline
WA_CE1R300_STR-VTWEG sy-vline
WA_CE1R300_STR-SPART sy-vline
WA_CE1R300_STR-HRKFT sy-vline
WA_CE1R300_STR-PLIKZ sy-vline
WA_CE1R300_STR-KSTAR sy-vline
WA_CE1R300_STR-PSPNR sy-vline
WA_CE1R300_STR-KSTRG sy-vline
WA_CE1R300_STR-RBELN sy-vline
WA_CE1R300_STR-RPOSN sy-vline
WA_CE1R300_STR-STO_BELNR sy-vline
WA_CE1R300_STR-STO_POSNR sy-vline
WA_CE1R300_STR-PRCTR sy-vline
WA_CE1R300_STR-PPRCTR sy-vline
WA_CE1R300_STR-RKESTATU sy-vline
WA_CE1R300_STR-TIMESTMP sy-vline
WA_CE1R300_STR-COPA_AWTYP sy-vline
WA_CE1R300_STR-COPA_AWORG sy-vline
WA_CE1R300_STR-COPA_BWZPT sy-vline
WA_CE1R300_STR-COPA_AWSYS sy-vline
WA_CE1R300_STR-ABTNR sy-vline
WA_CE1R300_STR-EKORG sy-vline
WA_CE1R300_STR-MATKL sy-vline
WA_CE1R300_STR-WGRU1 sy-vline
WA_CE1R300_STR-WGRU2 sy-vline
WA_CE1R300_STR-VV700_ME sy-vline
WA_CE1R300_STR-VV700 sy-vline
WA_CE1R300_STR-VV701 sy-vline
WA_CE1R300_STR-VV702 sy-vline
WA_CE1R300_STR-VV707 sy-vline
WA_CE1R300_STR-VV708 sy-vline
WA_CE1R300_STR-VV709 sy-vline
WA_CE1R300_STR-VV710 sy-vline
WA_CE1R300_STR-VV711 sy-vline
WA_CE1R300_STR-VV712 sy-vline
WA_CE1R300_STR-VV713 sy-vline
WA_CE1R300_STR-VV714 sy-vline
WA_CE1R300_STR-VV715 sy-vline
WA_CE1R300_STR-VV716 sy-vline
WA_CE1R300_STR-VV717 sy-vline
WA_CE1R300_STR-VV718 sy-vline
WA_CE1R300_STR-VV719 sy-vline
WA_CE1R300_STR-VV720 sy-vline
WA_CE1R300_STR-VV721 sy-vline
WA_CE1R300_STR-VV722 sy-vline
WA_CE1R300_STR-VV723 sy-vline
WA_CE1R300_STR-VV724 sy-vline
WA_CE1R300_STR-VV725 sy-vline
WA_CE1R300_STR-VV726 sy-vline
WA_CE1R300_STR-VV699 sy-vline
WA_CE1R300_STR-VV680 sy-vline
WA_CE1R300_STR-VV681 sy-vline
WA_CE1R300_STR-VV692 sy-vline
WA_CE1R300_STR-VV694 sy-vline
WA_CE1R300_STR-VV695 sy-vline
WA_CE1R300_STR-VV696 sy-vline
WA_CE1R300_STR-VV697 sy-vline
WA_CE1R300_STR-VV698 sy-vline
WA_CE1R300_STR-VV690 sy-vline
WA_CE1R300_STR-VV693 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.