ABAP Select data from SAP table CE1IDEA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CE1IDEA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CE1IDEA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CE1IDEA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CE1IDEA TYPE STANDARD TABLE OF CE1IDEA,
      WA_CE1IDEA TYPE CE1IDEA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CE1IDEA> TYPE CE1IDEA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CE1IDEA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CE1IDEA
  INTO TABLE IT_CE1IDEA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CE1IDEA
*  INTO TABLE @DATA(IT_CE1IDEA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CE1IDEA INDEX 1 INTO DATA(WA_CE1IDEA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CE1IDEA ASSIGNING <CE1IDEA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CE1IDEA>-MANDT = 1.
<CE1IDEA>-PALEDGER = 1.
<CE1IDEA>-VRGAR = 1.
<CE1IDEA>-VERSI = 1.
<CE1IDEA>-PERIO = 1.
ENDLOOP.

LOOP AT IT_CE1IDEA INTO WA_CE1IDEA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CE1IDEA-PAOBJNR, sy-vline,
WA_CE1IDEA-PASUBNR, sy-vline,
WA_CE1IDEA-BELNR, sy-vline,
WA_CE1IDEA-POSNR, sy-vline,
WA_CE1IDEA-HZDAT, sy-vline,
WA_CE1IDEA-USNAM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CE1IDEA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CE1IDEA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CE1IDEA INTO WA_CE1IDEA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit LEDBO, internal->external for field PALEDGER CALL FUNCTION 'CONVERSION_EXIT_LEDBO_OUTPUT' EXPORTING input = WA_CE1IDEA-PALEDGER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-PALEDGER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-VERSI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VERSI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field PERIO CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_CE1IDEA-PERIO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-PERIO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_CE1IDEA-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field ALTPERIO CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_CE1IDEA-ALTPERIO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-ALTPERIO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KNDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-KNDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-KNDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ARTNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CE1IDEA-ARTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-ARTNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSF CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_CE1IDEA-KURSF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-KURSF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSBK CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_CE1IDEA-KURSBK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-KURSBK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSKZ CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_CE1IDEA-KURSKZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-KURSKZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KAUFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-KAUFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-KAUFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RKAUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-RKAUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-RKAUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SKOST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-SKOST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-SKOST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRZNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-PRZNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-PRZNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KSTAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-KSTAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-KSTAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_CE1IDEA-PSPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-PSPNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-RBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-RBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STO_BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-STO_BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-STO_BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PPRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-PPRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-PPRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COPA_AWSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-COPA_AWSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-COPA_AWSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNWE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-KUNWE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-KUNWE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HIE01 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-HIE01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-HIE01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HIE02 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-HIE02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-HIE02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HIE03 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-HIE03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-HIE03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WWPRO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-WWPRO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-WWPRO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WWSDL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-WWSDL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-WWSDL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field CRMELEM CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_CE1IDEA-CRMELEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-CRMELEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CRMCSTY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CE1IDEA-CRMCSTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-CRMCSTY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VVOQT_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VVOQT_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VVOQT_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VVIQT_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VVIQT_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VVIQT_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VVSQT_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VVSQT_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VVSQT_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VVGRW_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VVGRW_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VVGRW_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VV550_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VV550_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VV550_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VV560_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VV560_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VV560_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VV570_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VV570_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VV570_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VV580_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VV580_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VV580_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VV495_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VV495_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VV495_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VVSTU_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VVSTU_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VVSTU_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VVOQU_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VVOQU_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VVOQU_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VV810_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VV810_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VV810_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VV820_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VV820_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VV820_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VV930_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VV930_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VV930_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VV931_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VV931_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VV931_ME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VVSV_ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CE1IDEA-VVSV_ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CE1IDEA-VVSV_ME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CE1IDEA_STR,
MANDT TYPE STRING,
PALEDGER TYPE STRING,
VRGAR TYPE STRING,
VERSI TYPE STRING,
PERIO TYPE STRING,
PAOBJNR TYPE STRING,
PASUBNR TYPE STRING,
BELNR TYPE STRING,
POSNR TYPE STRING,
HZDAT TYPE STRING,
USNAM TYPE STRING,
GJAHR TYPE STRING,
PERDE TYPE STRING,
WADAT TYPE STRING,
FADAT TYPE STRING,
BUDAT TYPE STRING,
ALTPERIO TYPE STRING,
PAPAOBJNR TYPE STRING,
PAPASUBNR TYPE STRING,
KNDNR TYPE STRING,
ARTNR TYPE STRING,
FKART TYPE STRING,
FRWAE TYPE STRING,
KURSF TYPE STRING,
KURSBK TYPE STRING,
KURSKZ TYPE STRING,
REC_WAERS TYPE STRING,
KAUFN TYPE STRING,
KDPOS TYPE STRING,
RKAUFNR TYPE STRING,
SKOST TYPE STRING,
PRZNR TYPE STRING,
BUKRS TYPE STRING,
KOKRS TYPE STRING,
WERKS TYPE STRING,
GSBER TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
HRKFT TYPE STRING,
PLIKZ TYPE STRING,
KSTAR TYPE STRING,
PSPNR TYPE STRING,
KSTRG TYPE STRING,
RBELN TYPE STRING,
RPOSN TYPE STRING,
STO_BELNR TYPE STRING,
STO_POSNR TYPE STRING,
PRCTR TYPE STRING,
PPRCTR TYPE STRING,
RKESTATU TYPE STRING,
TIMESTMP TYPE STRING,
COPA_AWTYP TYPE STRING,
COPA_AWORG TYPE STRING,
COPA_BWZPT TYPE STRING,
COPA_AWSYS TYPE STRING,
MATKL TYPE STRING,
MVGR1 TYPE STRING,
WWPH1 TYPE STRING,
WWPH2 TYPE STRING,
WWPH3 TYPE STRING,
WWPRC TYPE STRING,
WWSOP TYPE STRING,
WWSBU TYPE STRING,
KDGRP TYPE STRING,
KUKLA TYPE STRING,
BZIRK TYPE STRING,
BRSCH TYPE STRING,
WWREG TYPE STRING,
LAND1 TYPE STRING,
KUNWE TYPE STRING,
WWCST TYPE STRING,
WWRST TYPE STRING,
HIE01 TYPE STRING,
HIE02 TYPE STRING,
HIE03 TYPE STRING,
VRTNR TYPE STRING,
VKBUR TYPE STRING,
VKGRP TYPE STRING,
WWICI TYPE STRING,
AUGRU TYPE STRING,
WWPRO TYPE STRING,
WWSDL TYPE STRING,
PAPH1 TYPE STRING,
PAPH2 TYPE STRING,
PAPH3 TYPE STRING,
PAREG TYPE STRING,
SORHIST TYPE STRING,
WWMEA TYPE STRING,
WWQUA TYPE STRING,
WWSUR TYPE STRING,
REGIO TYPE STRING,
CRMELEM TYPE STRING,
CRMCSTY TYPE STRING,
ROUTE TYPE STRING,
VVOQT_ME TYPE STRING,
VVIQT_ME TYPE STRING,
VVSQT_ME TYPE STRING,
VVGRW_ME TYPE STRING,
VV550_ME TYPE STRING,
VV560_ME TYPE STRING,
VV570_ME TYPE STRING,
VV580_ME TYPE STRING,
VV495_ME TYPE STRING,
VVSTU_ME TYPE STRING,
VVOQU_ME TYPE STRING,
VV810_ME TYPE STRING,
VV820_ME TYPE STRING,
VV930_ME TYPE STRING,
VV931_ME TYPE STRING,
VVSV_ME TYPE STRING,
VVOQT TYPE STRING,
VVIQT TYPE STRING,
VVSQT TYPE STRING,
VVGRW TYPE STRING,
VV010 TYPE STRING,
VV020 TYPE STRING,
VV030 TYPE STRING,
VV040 TYPE STRING,
VV060 TYPE STRING,
VV070 TYPE STRING,
VV090 TYPE STRING,
VV100 TYPE STRING,
VV110 TYPE STRING,
VV120 TYPE STRING,
VV130 TYPE STRING,
VV140 TYPE STRING,
VV150 TYPE STRING,
VV160 TYPE STRING,
VV170 TYPE STRING,
VV180 TYPE STRING,
VV190 TYPE STRING,
VV200 TYPE STRING,
VV210 TYPE STRING,
VV220 TYPE STRING,
VV230 TYPE STRING,
VV240 TYPE STRING,
VV250 TYPE STRING,
VV260 TYPE STRING,
VV270 TYPE STRING,
VV280 TYPE STRING,
VV290 TYPE STRING,
VV300 TYPE STRING,
VV310 TYPE STRING,
VV320 TYPE STRING,
VV330 TYPE STRING,
VV340 TYPE STRING,
VV350 TYPE STRING,
VV360 TYPE STRING,
VV370 TYPE STRING,
VV380 TYPE STRING,
VV390 TYPE STRING,
VV400 TYPE STRING,
VV410 TYPE STRING,
VV420 TYPE STRING,
VV430 TYPE STRING,
VV440 TYPE STRING,
VV450 TYPE STRING,
VV460 TYPE STRING,
VV470 TYPE STRING,
VV480 TYPE STRING,
VV145 TYPE STRING,
VV075 TYPE STRING,
VV500 TYPE STRING,
VV510 TYPE STRING,
VV520 TYPE STRING,
VV530 TYPE STRING,
VV550 TYPE STRING,
VV560 TYPE STRING,
VV570 TYPE STRING,
VV580 TYPE STRING,
VV495 TYPE STRING,
VVSTU TYPE STRING,
VV155 TYPE STRING,
VV365 TYPE STRING,
VV364 TYPE STRING,
VVK15 TYPE STRING,
VVK20 TYPE STRING,
VVK25 TYPE STRING,
VVK30 TYPE STRING,
VVK10 TYPE STRING,
VVO10 TYPE STRING,
VVO20 TYPE STRING,
VVOQU TYPE STRING,
VV366 TYPE STRING,
VV367 TYPE STRING,
VV368 TYPE STRING,
VV151 TYPE STRING,
VV171 TYPE STRING,
VV181 TYPE STRING,
VV191 TYPE STRING,
VV201 TYPE STRING,
VV211 TYPE STRING,
VV251 TYPE STRING,
VV810 TYPE STRING,
VV820 TYPE STRING,
VV830 TYPE STRING,
VV840 TYPE STRING,
VV095 TYPE STRING,
VV713 TYPE STRING,
VV900 TYPE STRING,
VV910 TYPE STRING,
VV915 TYPE STRING,
VV920 TYPE STRING,
VV930 TYPE STRING,
VV931 TYPE STRING,
VV940 TYPE STRING,
VV950 TYPE STRING,
VV960 TYPE STRING,
VV970 TYPE STRING,
VV999 TYPE STRING,
VVADV TYPE STRING,
VVCGS TYPE STRING,
VVDEP TYPE STRING,
VVENG TYPE STRING,
VVNR TYPE STRING,
VVPSC TYPE STRING,
VVREN TYPE STRING,
VVREV TYPE STRING,
VVSD TYPE STRING,
VVCM2 TYPE STRING,
VVSV TYPE STRING,
VVLS1 TYPE STRING,
VVLS2 TYPE STRING,
VVLS3 TYPE STRING,END OF T_EKKO_STR. DATA: WA_CE1IDEA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CE1IDEA_STR-MANDT sy-vline
WA_CE1IDEA_STR-PALEDGER sy-vline
WA_CE1IDEA_STR-VRGAR sy-vline
WA_CE1IDEA_STR-VERSI sy-vline
WA_CE1IDEA_STR-PERIO sy-vline
WA_CE1IDEA_STR-PAOBJNR sy-vline
WA_CE1IDEA_STR-PASUBNR sy-vline
WA_CE1IDEA_STR-BELNR sy-vline
WA_CE1IDEA_STR-POSNR sy-vline
WA_CE1IDEA_STR-HZDAT sy-vline
WA_CE1IDEA_STR-USNAM sy-vline
WA_CE1IDEA_STR-GJAHR sy-vline
WA_CE1IDEA_STR-PERDE sy-vline
WA_CE1IDEA_STR-WADAT sy-vline
WA_CE1IDEA_STR-FADAT sy-vline
WA_CE1IDEA_STR-BUDAT sy-vline
WA_CE1IDEA_STR-ALTPERIO sy-vline
WA_CE1IDEA_STR-PAPAOBJNR sy-vline
WA_CE1IDEA_STR-PAPASUBNR sy-vline
WA_CE1IDEA_STR-KNDNR sy-vline
WA_CE1IDEA_STR-ARTNR sy-vline
WA_CE1IDEA_STR-FKART sy-vline
WA_CE1IDEA_STR-FRWAE sy-vline
WA_CE1IDEA_STR-KURSF sy-vline
WA_CE1IDEA_STR-KURSBK sy-vline
WA_CE1IDEA_STR-KURSKZ sy-vline
WA_CE1IDEA_STR-REC_WAERS sy-vline
WA_CE1IDEA_STR-KAUFN sy-vline
WA_CE1IDEA_STR-KDPOS sy-vline
WA_CE1IDEA_STR-RKAUFNR sy-vline
WA_CE1IDEA_STR-SKOST sy-vline
WA_CE1IDEA_STR-PRZNR sy-vline
WA_CE1IDEA_STR-BUKRS sy-vline
WA_CE1IDEA_STR-KOKRS sy-vline
WA_CE1IDEA_STR-WERKS sy-vline
WA_CE1IDEA_STR-GSBER sy-vline
WA_CE1IDEA_STR-VKORG sy-vline
WA_CE1IDEA_STR-VTWEG sy-vline
WA_CE1IDEA_STR-SPART sy-vline
WA_CE1IDEA_STR-HRKFT sy-vline
WA_CE1IDEA_STR-PLIKZ sy-vline
WA_CE1IDEA_STR-KSTAR sy-vline
WA_CE1IDEA_STR-PSPNR sy-vline
WA_CE1IDEA_STR-KSTRG sy-vline
WA_CE1IDEA_STR-RBELN sy-vline
WA_CE1IDEA_STR-RPOSN sy-vline
WA_CE1IDEA_STR-STO_BELNR sy-vline
WA_CE1IDEA_STR-STO_POSNR sy-vline
WA_CE1IDEA_STR-PRCTR sy-vline
WA_CE1IDEA_STR-PPRCTR sy-vline
WA_CE1IDEA_STR-RKESTATU sy-vline
WA_CE1IDEA_STR-TIMESTMP sy-vline
WA_CE1IDEA_STR-COPA_AWTYP sy-vline
WA_CE1IDEA_STR-COPA_AWORG sy-vline
WA_CE1IDEA_STR-COPA_BWZPT sy-vline
WA_CE1IDEA_STR-COPA_AWSYS sy-vline
WA_CE1IDEA_STR-MATKL sy-vline
WA_CE1IDEA_STR-MVGR1 sy-vline
WA_CE1IDEA_STR-WWPH1 sy-vline
WA_CE1IDEA_STR-WWPH2 sy-vline
WA_CE1IDEA_STR-WWPH3 sy-vline
WA_CE1IDEA_STR-WWPRC sy-vline
WA_CE1IDEA_STR-WWSOP sy-vline
WA_CE1IDEA_STR-WWSBU sy-vline
WA_CE1IDEA_STR-KDGRP sy-vline
WA_CE1IDEA_STR-KUKLA sy-vline
WA_CE1IDEA_STR-BZIRK sy-vline
WA_CE1IDEA_STR-BRSCH sy-vline
WA_CE1IDEA_STR-WWREG sy-vline
WA_CE1IDEA_STR-LAND1 sy-vline
WA_CE1IDEA_STR-KUNWE sy-vline
WA_CE1IDEA_STR-WWCST sy-vline
WA_CE1IDEA_STR-WWRST sy-vline
WA_CE1IDEA_STR-HIE01 sy-vline
WA_CE1IDEA_STR-HIE02 sy-vline
WA_CE1IDEA_STR-HIE03 sy-vline
WA_CE1IDEA_STR-VRTNR sy-vline
WA_CE1IDEA_STR-VKBUR sy-vline
WA_CE1IDEA_STR-VKGRP sy-vline
WA_CE1IDEA_STR-WWICI sy-vline
WA_CE1IDEA_STR-AUGRU sy-vline
WA_CE1IDEA_STR-WWPRO sy-vline
WA_CE1IDEA_STR-WWSDL sy-vline
WA_CE1IDEA_STR-PAPH1 sy-vline
WA_CE1IDEA_STR-PAPH2 sy-vline
WA_CE1IDEA_STR-PAPH3 sy-vline
WA_CE1IDEA_STR-PAREG sy-vline
WA_CE1IDEA_STR-SORHIST sy-vline
WA_CE1IDEA_STR-WWMEA sy-vline
WA_CE1IDEA_STR-WWQUA sy-vline
WA_CE1IDEA_STR-WWSUR sy-vline
WA_CE1IDEA_STR-REGIO sy-vline
WA_CE1IDEA_STR-CRMELEM sy-vline
WA_CE1IDEA_STR-CRMCSTY sy-vline
WA_CE1IDEA_STR-ROUTE sy-vline
WA_CE1IDEA_STR-VVOQT_ME sy-vline
WA_CE1IDEA_STR-VVIQT_ME sy-vline
WA_CE1IDEA_STR-VVSQT_ME sy-vline
WA_CE1IDEA_STR-VVGRW_ME sy-vline
WA_CE1IDEA_STR-VV550_ME sy-vline
WA_CE1IDEA_STR-VV560_ME sy-vline
WA_CE1IDEA_STR-VV570_ME sy-vline
WA_CE1IDEA_STR-VV580_ME sy-vline
WA_CE1IDEA_STR-VV495_ME sy-vline
WA_CE1IDEA_STR-VVSTU_ME sy-vline
WA_CE1IDEA_STR-VVOQU_ME sy-vline
WA_CE1IDEA_STR-VV810_ME sy-vline
WA_CE1IDEA_STR-VV820_ME sy-vline
WA_CE1IDEA_STR-VV930_ME sy-vline
WA_CE1IDEA_STR-VV931_ME sy-vline
WA_CE1IDEA_STR-VVSV_ME sy-vline
WA_CE1IDEA_STR-VVOQT sy-vline
WA_CE1IDEA_STR-VVIQT sy-vline
WA_CE1IDEA_STR-VVSQT sy-vline
WA_CE1IDEA_STR-VVGRW sy-vline
WA_CE1IDEA_STR-VV010 sy-vline
WA_CE1IDEA_STR-VV020 sy-vline
WA_CE1IDEA_STR-VV030 sy-vline
WA_CE1IDEA_STR-VV040 sy-vline
WA_CE1IDEA_STR-VV060 sy-vline
WA_CE1IDEA_STR-VV070 sy-vline
WA_CE1IDEA_STR-VV090 sy-vline
WA_CE1IDEA_STR-VV100 sy-vline
WA_CE1IDEA_STR-VV110 sy-vline
WA_CE1IDEA_STR-VV120 sy-vline
WA_CE1IDEA_STR-VV130 sy-vline
WA_CE1IDEA_STR-VV140 sy-vline
WA_CE1IDEA_STR-VV150 sy-vline
WA_CE1IDEA_STR-VV160 sy-vline
WA_CE1IDEA_STR-VV170 sy-vline
WA_CE1IDEA_STR-VV180 sy-vline
WA_CE1IDEA_STR-VV190 sy-vline
WA_CE1IDEA_STR-VV200 sy-vline
WA_CE1IDEA_STR-VV210 sy-vline
WA_CE1IDEA_STR-VV220 sy-vline
WA_CE1IDEA_STR-VV230 sy-vline
WA_CE1IDEA_STR-VV240 sy-vline
WA_CE1IDEA_STR-VV250 sy-vline
WA_CE1IDEA_STR-VV260 sy-vline
WA_CE1IDEA_STR-VV270 sy-vline
WA_CE1IDEA_STR-VV280 sy-vline
WA_CE1IDEA_STR-VV290 sy-vline
WA_CE1IDEA_STR-VV300 sy-vline
WA_CE1IDEA_STR-VV310 sy-vline
WA_CE1IDEA_STR-VV320 sy-vline
WA_CE1IDEA_STR-VV330 sy-vline
WA_CE1IDEA_STR-VV340 sy-vline
WA_CE1IDEA_STR-VV350 sy-vline
WA_CE1IDEA_STR-VV360 sy-vline
WA_CE1IDEA_STR-VV370 sy-vline
WA_CE1IDEA_STR-VV380 sy-vline
WA_CE1IDEA_STR-VV390 sy-vline
WA_CE1IDEA_STR-VV400 sy-vline
WA_CE1IDEA_STR-VV410 sy-vline
WA_CE1IDEA_STR-VV420 sy-vline
WA_CE1IDEA_STR-VV430 sy-vline
WA_CE1IDEA_STR-VV440 sy-vline
WA_CE1IDEA_STR-VV450 sy-vline
WA_CE1IDEA_STR-VV460 sy-vline
WA_CE1IDEA_STR-VV470 sy-vline
WA_CE1IDEA_STR-VV480 sy-vline
WA_CE1IDEA_STR-VV145 sy-vline
WA_CE1IDEA_STR-VV075 sy-vline
WA_CE1IDEA_STR-VV500 sy-vline
WA_CE1IDEA_STR-VV510 sy-vline
WA_CE1IDEA_STR-VV520 sy-vline
WA_CE1IDEA_STR-VV530 sy-vline
WA_CE1IDEA_STR-VV550 sy-vline
WA_CE1IDEA_STR-VV560 sy-vline
WA_CE1IDEA_STR-VV570 sy-vline
WA_CE1IDEA_STR-VV580 sy-vline
WA_CE1IDEA_STR-VV495 sy-vline
WA_CE1IDEA_STR-VVSTU sy-vline
WA_CE1IDEA_STR-VV155 sy-vline
WA_CE1IDEA_STR-VV365 sy-vline
WA_CE1IDEA_STR-VV364 sy-vline
WA_CE1IDEA_STR-VVK15 sy-vline
WA_CE1IDEA_STR-VVK20 sy-vline
WA_CE1IDEA_STR-VVK25 sy-vline
WA_CE1IDEA_STR-VVK30 sy-vline
WA_CE1IDEA_STR-VVK10 sy-vline
WA_CE1IDEA_STR-VVO10 sy-vline
WA_CE1IDEA_STR-VVO20 sy-vline
WA_CE1IDEA_STR-VVOQU sy-vline
WA_CE1IDEA_STR-VV366 sy-vline
WA_CE1IDEA_STR-VV367 sy-vline
WA_CE1IDEA_STR-VV368 sy-vline
WA_CE1IDEA_STR-VV151 sy-vline
WA_CE1IDEA_STR-VV171 sy-vline
WA_CE1IDEA_STR-VV181 sy-vline
WA_CE1IDEA_STR-VV191 sy-vline
WA_CE1IDEA_STR-VV201 sy-vline
WA_CE1IDEA_STR-VV211 sy-vline
WA_CE1IDEA_STR-VV251 sy-vline
WA_CE1IDEA_STR-VV810 sy-vline
WA_CE1IDEA_STR-VV820 sy-vline
WA_CE1IDEA_STR-VV830 sy-vline
WA_CE1IDEA_STR-VV840 sy-vline
WA_CE1IDEA_STR-VV095 sy-vline
WA_CE1IDEA_STR-VV713 sy-vline
WA_CE1IDEA_STR-VV900 sy-vline
WA_CE1IDEA_STR-VV910 sy-vline
WA_CE1IDEA_STR-VV915 sy-vline
WA_CE1IDEA_STR-VV920 sy-vline
WA_CE1IDEA_STR-VV930 sy-vline
WA_CE1IDEA_STR-VV931 sy-vline
WA_CE1IDEA_STR-VV940 sy-vline
WA_CE1IDEA_STR-VV950 sy-vline
WA_CE1IDEA_STR-VV960 sy-vline
WA_CE1IDEA_STR-VV970 sy-vline
WA_CE1IDEA_STR-VV999 sy-vline
WA_CE1IDEA_STR-VVADV sy-vline
WA_CE1IDEA_STR-VVCGS sy-vline
WA_CE1IDEA_STR-VVDEP sy-vline
WA_CE1IDEA_STR-VVENG sy-vline
WA_CE1IDEA_STR-VVNR sy-vline
WA_CE1IDEA_STR-VVPSC sy-vline
WA_CE1IDEA_STR-VVREN sy-vline
WA_CE1IDEA_STR-VVREV sy-vline
WA_CE1IDEA_STR-VVSD sy-vline
WA_CE1IDEA_STR-VVCM2 sy-vline
WA_CE1IDEA_STR-VVSV sy-vline
WA_CE1IDEA_STR-VVLS1 sy-vline
WA_CE1IDEA_STR-VVLS2 sy-vline
WA_CE1IDEA_STR-VVLS3 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.