ABAP Select data from SAP table CDFSASSGMTMNTBFL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CDFSASSGMTMNTBFL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CDFSASSGMTMNTBFL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CDFSASSGMTMNTBFL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CDFSASSGMTMNTBFL TYPE STANDARD TABLE OF CDFSASSGMTMNTBFL,
      WA_CDFSASSGMTMNTBFL TYPE CDFSASSGMTMNTBFL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CDFSASSGMTMNTBFL> TYPE CDFSASSGMTMNTBFL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CDFSASSGMTMNTBFL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CDFSASSGMTMNTBFL
  INTO TABLE IT_CDFSASSGMTMNTBFL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CDFSASSGMTMNTBFL
*  INTO TABLE @DATA(IT_CDFSASSGMTMNTBFL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CDFSASSGMTMNTBFL INDEX 1 INTO DATA(WA_CDFSASSGMTMNTBFL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CDFSASSGMTMNTBFL ASSIGNING <CDFSASSGMTMNTBFL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CDFSASSGMTMNTBFL>-MANDT = 1.
<CDFSASSGMTMNTBFL>-DFSASSGMTUUID = 1.
<CDFSASSGMTMNTBFL>-DRAFTUUID = 1.
<CDFSASSGMTMNTBFL>-DFSASSGMTACTIVEDRAFTCRITLTY = 1.
<CDFSASSGMTMNTBFL>-DFSASSGMTACTIVEDRAFT = 1.
ENDLOOP.

LOOP AT IT_CDFSASSGMTMNTBFL INTO WA_CDFSASSGMTMNTBFL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CDFSASSGMTMNTBFL-HASACTIVEENTITY, sy-vline,
WA_CDFSASSGMTMNTBFL-HASDRAFTENTITY, sy-vline,
WA_CDFSASSGMTMNTBFL-DFSASSGMTCREATIONDATETIME, sy-vline,
WA_CDFSASSGMTMNTBFL-DFSASSGMTCREATEDBYUSER, sy-vline,
WA_CDFSASSGMTMNTBFL-DFSASSGMTCHANGEDATETIME, sy-vline,
WA_CDFSASSGMTMNTBFL-DFSASSGMTLASTCHGDBYUSER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CDFSASSGMTMNTBFL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CDFSASSGMTMNTBFL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CDFSASSGMTMNTBFL INTO WA_CDFSASSGMTMNTBFL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CDFSASSGMTMNTBFL_STR,
MANDT TYPE STRING,
DFSASSGMTUUID TYPE STRING,
DRAFTUUID TYPE STRING,
DFSASSGMTACTIVEDRAFTCRITLTY TYPE STRING,
DFSASSGMTACTIVEDRAFT TYPE STRING,
HASACTIVEENTITY TYPE STRING,
HASDRAFTENTITY TYPE STRING,
DFSASSGMTCREATIONDATETIME TYPE STRING,
DFSASSGMTCREATEDBYUSER TYPE STRING,
DFSASSGMTCHANGEDATETIME TYPE STRING,
DFSASSGMTLASTCHGDBYUSER TYPE STRING,
DFSASSGMTVALDTYSTRTDATE TYPE STRING,
DFSASSGMTVALDTYSTRTTIME TYPE STRING,
DFSASSGMTVALDTYENDDATE TYPE STRING,
DFSASSGMTVALDTYENDTIME TYPE STRING,
DFSASSGMTVALDTYTIMEZONE TYPE STRING,
DFSASSGMTSOURCETYPE TYPE STRING,
DFSASSGMTTYPE TYPE STRING,
DFSASSGMTISDEFAULTASSIGNMENT TYPE STRING,
DFSASSGMTEXTERNALPRODUCTGROUP TYPE STRING,
FORCEELEMENTORGTARGETUUID TYPE STRING,
FORCEELEMENTORGSRCEUUID TYPE STRING,
DFSASSGMTSTATUSOBJECT TYPE STRING,
DFSASSGMTSTATUSCODE TYPE STRING,
STATUS TYPE STRING,
TIMEZONETEXT TYPE STRING,
FORCEELEMENTORGSRCEID TYPE STRING,
FORCEELEMENTORGTARGETID TYPE STRING,
FRCELMNTORGTYPE TYPE STRING,
FORCEELEMENTORGUUID TYPE STRING,
FRCELMNTORGNAME TYPE STRING,
FRCELMNTORGPLANVERSION TYPE STRING,
FRCELMNTORGSYMBOL TYPE STRING,
FORCEELEMENTORGID TYPE STRING,
STATUSCRITICALITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_CDFSASSGMTMNTBFL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CDFSASSGMTMNTBFL_STR-MANDT sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTUUID sy-vline
WA_CDFSASSGMTMNTBFL_STR-DRAFTUUID sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTACTIVEDRAFTCRITLTY sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTACTIVEDRAFT sy-vline
WA_CDFSASSGMTMNTBFL_STR-HASACTIVEENTITY sy-vline
WA_CDFSASSGMTMNTBFL_STR-HASDRAFTENTITY sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTCREATIONDATETIME sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTCREATEDBYUSER sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTCHANGEDATETIME sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTLASTCHGDBYUSER sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTVALDTYSTRTDATE sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTVALDTYSTRTTIME sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTVALDTYENDDATE sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTVALDTYENDTIME sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTVALDTYTIMEZONE sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTSOURCETYPE sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTTYPE sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTISDEFAULTASSIGNMENT sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTEXTERNALPRODUCTGROUP sy-vline
WA_CDFSASSGMTMNTBFL_STR-FORCEELEMENTORGTARGETUUID sy-vline
WA_CDFSASSGMTMNTBFL_STR-FORCEELEMENTORGSRCEUUID sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTSTATUSOBJECT sy-vline
WA_CDFSASSGMTMNTBFL_STR-DFSASSGMTSTATUSCODE sy-vline
WA_CDFSASSGMTMNTBFL_STR-STATUS sy-vline
WA_CDFSASSGMTMNTBFL_STR-TIMEZONETEXT sy-vline
WA_CDFSASSGMTMNTBFL_STR-FORCEELEMENTORGSRCEID sy-vline
WA_CDFSASSGMTMNTBFL_STR-FORCEELEMENTORGTARGETID sy-vline
WA_CDFSASSGMTMNTBFL_STR-FRCELMNTORGTYPE sy-vline
WA_CDFSASSGMTMNTBFL_STR-FORCEELEMENTORGUUID sy-vline
WA_CDFSASSGMTMNTBFL_STR-FRCELMNTORGNAME sy-vline
WA_CDFSASSGMTMNTBFL_STR-FRCELMNTORGPLANVERSION sy-vline
WA_CDFSASSGMTMNTBFL_STR-FRCELMNTORGSYMBOL sy-vline
WA_CDFSASSGMTMNTBFL_STR-FORCEELEMENTORGID sy-vline
WA_CDFSASSGMTMNTBFL_STR-STATUSCRITICALITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.