ABAP Select data from SAP table CDFSASSGMTACOTVH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CDFSASSGMTACOTVH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CDFSASSGMTACOTVH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CDFSASSGMTACOTVH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CDFSASSGMTACOTVH TYPE STANDARD TABLE OF CDFSASSGMTACOTVH,
      WA_CDFSASSGMTACOTVH TYPE CDFSASSGMTACOTVH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CDFSASSGMTACOTVH> TYPE CDFSASSGMTACOTVH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CDFSASSGMTACOTVH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CDFSASSGMTACOTVH
  INTO TABLE IT_CDFSASSGMTACOTVH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CDFSASSGMTACOTVH
*  INTO TABLE @DATA(IT_CDFSASSGMTACOTVH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CDFSASSGMTACOTVH INDEX 1 INTO DATA(WA_CDFSASSGMTACOTVH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CDFSASSGMTACOTVH ASSIGNING <CDFSASSGMTACOTVH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CDFSASSGMTACOTVH>-MANDT = 1.
<CDFSASSGMTACOTVH>-FLXMTPLOBJVARIANTACCOGPRTUUID = 1.
<CDFSASSGMTACOTVH>-FLXBLMATLPLNGOBJVARIANTUUID = 1.
<CDFSASSGMTACOTVH>-FLXBLMATLPLNGOBJECTUUID = 1.
<CDFSASSGMTACOTVH>-FLXMTPLOBJVARSTATUSDESCRIPTION = 1.
ENDLOOP.

LOOP AT IT_CDFSASSGMTACOTVH INTO WA_CDFSASSGMTACOTVH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CDFSASSGMTACOTVH-FLXMTPLOBJVARACCOGPARTITEM, sy-vline,
WA_CDFSASSGMTACOTVH-FLXMTPLOBJVARACCOGPARTASSGMT, sy-vline,
WA_CDFSASSGMTACOTVH-FLXMTPLOBJVARACCOGPRTREFOBJID, sy-vline,
WA_CDFSASSGMTACOTVH-FLXMTPLOBJVARACCOGPRTREFVARID, sy-vline,
WA_CDFSASSGMTACOTVH-FLXBLMATLPLNGOBJECTID, sy-vline,
ENDLOOP. *Add any further fields from structure WA_CDFSASSGMTACOTVH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CDFSASSGMTACOTVH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CDFSASSGMTACOTVH INTO WA_CDFSASSGMTACOTVH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CDFSASSGMTACOTVH_STR,
MANDT TYPE STRING,
FLXMTPLOBJVARIANTACCOGPRTUUID TYPE STRING,
FLXBLMATLPLNGOBJVARIANTUUID TYPE STRING,
FLXBLMATLPLNGOBJECTUUID TYPE STRING,
FLXMTPLOBJVARSTATUSDESCRIPTION TYPE STRING,
FLXMTPLOBJVARACCOGPARTITEM TYPE STRING,
FLXMTPLOBJVARACCOGPARTASSGMT TYPE STRING,
FLXMTPLOBJVARACCOGPRTREFOBJID TYPE STRING,
FLXMTPLOBJVARACCOGPRTREFVARID TYPE STRING,
FLXBLMATLPLNGOBJECTID TYPE STRING,END OF T_EKKO_STR. DATA: WA_CDFSASSGMTACOTVH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CDFSASSGMTACOTVH_STR-MANDT sy-vline
WA_CDFSASSGMTACOTVH_STR-FLXMTPLOBJVARIANTACCOGPRTUUID sy-vline
WA_CDFSASSGMTACOTVH_STR-FLXBLMATLPLNGOBJVARIANTUUID sy-vline
WA_CDFSASSGMTACOTVH_STR-FLXBLMATLPLNGOBJECTUUID sy-vline
WA_CDFSASSGMTACOTVH_STR-FLXMTPLOBJVARSTATUSDESCRIPTION sy-vline
WA_CDFSASSGMTACOTVH_STR-FLXMTPLOBJVARACCOGPARTITEM sy-vline
WA_CDFSASSGMTACOTVH_STR-FLXMTPLOBJVARACCOGPARTASSGMT sy-vline
WA_CDFSASSGMTACOTVH_STR-FLXMTPLOBJVARACCOGPRTREFOBJID sy-vline
WA_CDFSASSGMTACOTVH_STR-FLXMTPLOBJVARACCOGPRTREFVARID sy-vline
WA_CDFSASSGMTACOTVH_STR-FLXBLMATLPLNGOBJECTID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.