ABAP Select data from SAP table CDESK_TRAFO_TYPE_CAD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CDESK_TRAFO_TYPE_CAD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CDESK_TRAFO_TYPE_CAD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CDESK_TRAFO_TYPE_CAD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CDESK_TRAFO_TYPE_CAD TYPE STANDARD TABLE OF CDESK_TRAFO_TYPE_CAD,
      WA_CDESK_TRAFO_TYPE_CAD TYPE CDESK_TRAFO_TYPE_CAD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CDESK_TRAFO_TYPE_CAD> TYPE CDESK_TRAFO_TYPE_CAD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CDESK_TRAFO_TYPE_CAD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CDESK_TRAFO_TYPE_CAD
  INTO TABLE IT_CDESK_TRAFO_TYPE_CAD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CDESK_TRAFO_TYPE_CAD
*  INTO TABLE @DATA(IT_CDESK_TRAFO_TYPE_CAD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CDESK_TRAFO_TYPE_CAD INDEX 1 INTO DATA(WA_CDESK_TRAFO_TYPE_CAD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CDESK_TRAFO_TYPE_CAD ASSIGNING <CDESK_TRAFO_TYPE_CAD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CDESK_TRAFO_TYPE_CAD>-GUID_IDENT = 1.
<CDESK_TRAFO_TYPE_CAD>-GUID_PRED = 1.
<CDESK_TRAFO_TYPE_CAD>-LOCOX = 1.
<CDESK_TRAFO_TYPE_CAD>-LOCOY = 1.
<CDESK_TRAFO_TYPE_CAD>-LOCOZ = 1.
ENDLOOP.

LOOP AT IT_CDESK_TRAFO_TYPE_CAD INTO WA_CDESK_TRAFO_TYPE_CAD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CDESK_TRAFO_TYPE_CAD-AXIS1X, sy-vline,
WA_CDESK_TRAFO_TYPE_CAD-AXIS1Y, sy-vline,
WA_CDESK_TRAFO_TYPE_CAD-AXIS1Z, sy-vline,
WA_CDESK_TRAFO_TYPE_CAD-AXIS2X, sy-vline,
WA_CDESK_TRAFO_TYPE_CAD-AXIS2Y, sy-vline,
WA_CDESK_TRAFO_TYPE_CAD-AXIS2Z, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CDESK_TRAFO_TYPE_CAD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CDESK_TRAFO_TYPE_CAD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CDESK_TRAFO_TYPE_CAD INTO WA_CDESK_TRAFO_TYPE_CAD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CDESK_TRAFO_TYPE_CAD_STR,
GUID_IDENT TYPE STRING,
GUID_PRED TYPE STRING,
LOCOX TYPE STRING,
LOCOY TYPE STRING,
LOCOZ TYPE STRING,
AXIS1X TYPE STRING,
AXIS1Y TYPE STRING,
AXIS1Z TYPE STRING,
AXIS2X TYPE STRING,
AXIS2Y TYPE STRING,
AXIS2Z TYPE STRING,
AXIS3X TYPE STRING,
AXIS3Y TYPE STRING,
AXIS3Z TYPE STRING,
SCALE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CDESK_TRAFO_TYPE_CAD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-GUID_IDENT sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-GUID_PRED sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-LOCOX sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-LOCOY sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-LOCOZ sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-AXIS1X sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-AXIS1Y sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-AXIS1Z sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-AXIS2X sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-AXIS2Y sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-AXIS2Z sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-AXIS3X sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-AXIS3Y sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-AXIS3Z sy-vline
WA_CDESK_TRAFO_TYPE_CAD_STR-SCALE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.