ABAP Select data from SAP table CCTRLCHTCHARRSLT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCTRLCHTCHARRSLT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCTRLCHTCHARRSLT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCTRLCHTCHARRSLT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCTRLCHTCHARRSLT TYPE STANDARD TABLE OF CCTRLCHTCHARRSLT,
      WA_CCTRLCHTCHARRSLT TYPE CCTRLCHTCHARRSLT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCTRLCHTCHARRSLT> TYPE CCTRLCHTCHARRSLT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCTRLCHTCHARRSLT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCTRLCHTCHARRSLT
  INTO TABLE IT_CCTRLCHTCHARRSLT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCTRLCHTCHARRSLT
*  INTO TABLE @DATA(IT_CCTRLCHTCHARRSLT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCTRLCHTCHARRSLT INDEX 1 INTO DATA(WA_CCTRLCHTCHARRSLT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCTRLCHTCHARRSLT ASSIGNING <CCTRLCHTCHARRSLT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCTRLCHTCHARRSLT>-MANDT = 1.
<CCTRLCHTCHARRSLT>-INSPECTIONLOT = 1.
<CCTRLCHTCHARRSLT>-INSPECTIONCHARACTERISTIC = 1.
<CCTRLCHTCHARRSLT>-INSPPLANOPERATIONINTERNALID = 1.
<CCTRLCHTCHARRSLT>-INSPECTIONSUBSETINTERNALID = 1.
ENDLOOP.

LOOP AT IT_CCTRLCHTCHARRSLT INTO WA_CCTRLCHTCHARRSLT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCTRLCHTCHARRSLT-QUALITYCONTROLCHART, sy-vline,
WA_CCTRLCHTCHARRSLT-INSPECTIONOPERATION, sy-vline,
WA_CCTRLCHTCHARRSLT-OPERATIONTEXT, sy-vline,
WA_CCTRLCHTCHARRSLT-INSPECTIONMETHOD, sy-vline,
WA_CCTRLCHTCHARRSLT-INSPECTIONMETHODTEXT, sy-vline,
WA_CCTRLCHTCHARRSLT-INSPSPECIMPORTANCECODETEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCTRLCHTCHARRSLT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCTRLCHTCHARRSLT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCTRLCHTCHARRSLT INTO WA_CCTRLCHTCHARRSLT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCTRLCHTCHARRSLT-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCTRLCHTCHARRSLT-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QUALITYCONTROLCHART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCTRLCHTCHARRSLT-QUALITYCONTROLCHART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCTRLCHTCHARRSLT-QUALITYCONTROLCHART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field INSPECTIONOPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CCTRLCHTCHARRSLT-INSPECTIONOPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCTRLCHTCHARRSLT-INSPECTIONOPERATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONMETHOD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCTRLCHTCHARRSLT-INSPECTIONMETHOD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCTRLCHTCHARRSLT-INSPECTIONMETHOD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCTRLCHTCHARRSLT-INSPECTIONSPECIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCTRLCHTCHARRSLT-INSPECTIONSPECIFICATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATIONVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCTRLCHTCHARRSLT-INSPECTIONSPECIFICATIONVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCTRLCHTCHARRSLT-INSPECTIONSPECIFICATIONVERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INSPCHARACTERISTICSAMPLEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CCTRLCHTCHARRSLT-INSPCHARACTERISTICSAMPLEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCTRLCHTCHARRSLT-INSPCHARACTERISTICSAMPLEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONMETHODVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCTRLCHTCHARRSLT-INSPECTIONMETHODVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCTRLCHTCHARRSLT-INSPECTIONMETHODVERSION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCTRLCHTCHARRSLT_STR,
MANDT TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPECTIONCHARACTERISTIC TYPE STRING,
INSPPLANOPERATIONINTERNALID TYPE STRING,
INSPECTIONSUBSETINTERNALID TYPE STRING,
QUALITYCONTROLCHART TYPE STRING,
INSPECTIONOPERATION TYPE STRING,
OPERATIONTEXT TYPE STRING,
INSPECTIONMETHOD TYPE STRING,
INSPECTIONMETHODTEXT TYPE STRING,
INSPSPECIMPORTANCECODETEXT TYPE STRING,
INSPECTIONSPECIFICATION TYPE STRING,
INSPECTIONSPECIFICATIONTEXT TYPE STRING,
INSPECTIONSPECIFICATIONPLANT TYPE STRING,
INSPECTIONSPECIFICATIONVERSION TYPE STRING,
INSPSPECISQUANTITATIVE TYPE STRING,
INSPECTIONSPECIFICATIONUNIT TYPE STRING,
INSPSPECRECORDINGTYPE TYPE STRING,
INSPSPECUPPERLIMIT TYPE STRING,
INSPSPECHASUPPERLIMIT TYPE STRING,
INSPSPECLOWERLIMIT TYPE STRING,
INSPSPECHASLOWERLIMIT TYPE STRING,
INSPSPECDECIMALPLACES TYPE STRING,
INSPCHARACTERISTICSAMPLESIZE TYPE STRING,
INSPCHARACTERISTICSAMPLEUNIT TYPE STRING,
INSPSPECSAMPLEQUANTITYFACTOR TYPE STRING,
INSPSPECISMEASUREDVALUERQD TYPE STRING,
SELECTEDCODESETTEXT TYPE STRING,
INSPECTIONMETHODPLANT TYPE STRING,
INSPECTIONMETHODVERSION TYPE STRING,
INSPECTIONVALUATIONRESULT TYPE STRING,
INSPRESULTVALIDVALUESNUMBER TYPE STRING,
INSPRSLTNONCONFORMINGVALSNMBR TYPE STRING,
INSPECTIONRESULTMEANVALUE TYPE STRING,
CHARACTERISTICATTRIBUTECODETXT TYPE STRING,
CHARACTERISTICATTRIBUTECODE TYPE STRING,
INSPECTIONRESULTHASMEANVALUE TYPE STRING,
CHARACTERISTICATTRIBUTECODEGRP TYPE STRING,
INSPECTIONRESULTSTATUSTEXT TYPE STRING,
INSPRSLTINSPNONCONFORMANCECT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCTRLCHTCHARRSLT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCTRLCHTCHARRSLT_STR-MANDT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONLOT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONCHARACTERISTIC sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPPLANOPERATIONINTERNALID sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONSUBSETINTERNALID sy-vline
WA_CCTRLCHTCHARRSLT_STR-QUALITYCONTROLCHART sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONOPERATION sy-vline
WA_CCTRLCHTCHARRSLT_STR-OPERATIONTEXT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONMETHOD sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONMETHODTEXT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPSPECIMPORTANCECODETEXT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONSPECIFICATION sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONSPECIFICATIONTEXT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONSPECIFICATIONPLANT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONSPECIFICATIONVERSION sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPSPECISQUANTITATIVE sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONSPECIFICATIONUNIT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPSPECRECORDINGTYPE sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPSPECUPPERLIMIT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPSPECHASUPPERLIMIT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPSPECLOWERLIMIT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPSPECHASLOWERLIMIT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPSPECDECIMALPLACES sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPCHARACTERISTICSAMPLESIZE sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPCHARACTERISTICSAMPLEUNIT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPSPECSAMPLEQUANTITYFACTOR sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPSPECISMEASUREDVALUERQD sy-vline
WA_CCTRLCHTCHARRSLT_STR-SELECTEDCODESETTEXT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONMETHODPLANT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONMETHODVERSION sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONVALUATIONRESULT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPRESULTVALIDVALUESNUMBER sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPRSLTNONCONFORMINGVALSNMBR sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONRESULTMEANVALUE sy-vline
WA_CCTRLCHTCHARRSLT_STR-CHARACTERISTICATTRIBUTECODETXT sy-vline
WA_CCTRLCHTCHARRSLT_STR-CHARACTERISTICATTRIBUTECODE sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONRESULTHASMEANVALUE sy-vline
WA_CCTRLCHTCHARRSLT_STR-CHARACTERISTICATTRIBUTECODEGRP sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPECTIONRESULTSTATUSTEXT sy-vline
WA_CCTRLCHTCHARRSLT_STR-INSPRSLTINSPNONCONFORMANCECT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.