ABAP Select data from SAP table CCSUPLRMATLTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCSUPLRMATLTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCSUPLRMATLTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCSUPLRMATLTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCSUPLRMATLTP TYPE STANDARD TABLE OF CCSUPLRMATLTP,
      WA_CCSUPLRMATLTP TYPE CCSUPLRMATLTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCSUPLRMATLTP> TYPE CCSUPLRMATLTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCSUPLRMATLTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCSUPLRMATLTP
  INTO TABLE IT_CCSUPLRMATLTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCSUPLRMATLTP
*  INTO TABLE @DATA(IT_CCSUPLRMATLTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCSUPLRMATLTP INDEX 1 INTO DATA(WA_CCSUPLRMATLTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCSUPLRMATLTP ASSIGNING <CCSUPLRMATLTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCSUPLRMATLTP>-MANDT = 1.
<CCSUPLRMATLTP>-CHMLSUPLRMATLUUID = 1.
<CCSUPLRMATLTP>-ACTIVECHMLSUPLRMATLUUID = 1.
<CCSUPLRMATLTP>-RESPONSIBLEUNIT = 1.
<CCSUPLRMATLTP>-RESPONSIBLEUNITNAME = 1.
ENDLOOP.

LOOP AT IT_CCSUPLRMATLTP INTO WA_CCSUPLRMATLTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCSUPLRMATLTP-CHMLSUPLRMATLNAME, sy-vline,
WA_CCSUPLRMATLTP-SUPPLIERMATERIALNUMBER, sy-vline,
WA_CCSUPLRMATLTP-CHMLCMPLNCINFOUUID, sy-vline,
WA_CCSUPLRMATLTP-CHMLCMPLNCINFONAVGNLINK, sy-vline,
WA_CCSUPLRMATLTP-CHMLCMPLNCINFOCOMBINEDNAME, sy-vline,
WA_CCSUPLRMATLTP-BUSINESSPARTNERSUPPLIER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCSUPLRMATLTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCSUPLRMATLTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCSUPLRMATLTP INTO WA_CCSUPLRMATLTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BUSINESSPARTNERSUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCSUPLRMATLTP-BUSINESSPARTNERSUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCSUPLRMATLTP-BUSINESSPARTNERSUPPLIER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCSUPLRMATLTP_STR,
MANDT TYPE STRING,
CHMLSUPLRMATLUUID TYPE STRING,
ACTIVECHMLSUPLRMATLUUID TYPE STRING,
RESPONSIBLEUNIT TYPE STRING,
RESPONSIBLEUNITNAME TYPE STRING,
CHMLSUPLRMATLNAME TYPE STRING,
SUPPLIERMATERIALNUMBER TYPE STRING,
CHMLCMPLNCINFOUUID TYPE STRING,
CHMLCMPLNCINFONAVGNLINK TYPE STRING,
CHMLCMPLNCINFOCOMBINEDNAME TYPE STRING,
BUSINESSPARTNERSUPPLIER TYPE STRING,
SUPPLIERNAME TYPE STRING,
SUPPLIERMATERIALCOMBINEDNAME TYPE STRING,
CHMLSUPLRMATLDATASTATUS TYPE STRING,
CHMLSUPLRMATLDATASTATUSNAME TYPE STRING,
CHMLSUPLRMATLDATASTSCRITLTY TYPE STRING,
CHMLSUPLRMATLSUPLRSTS TYPE STRING,
CHMLSUPLRMATLSUPLRSTSNAME TYPE STRING,
CHMLSUPLRMATLSUPLRSTSCRITLTY TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
LASTCHANGEDBYUSERNAME TYPE STRING,
CHMLSUPLRMATLISOUTDATED TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
CHMLCOMPOSITIONUUID TYPE STRING,
CHMLCMPSTNINPROCSTATUS TYPE STRING,
CHMLCMPSTNRELDSTATUS TYPE STRING,
CHMLCOMPOSITIONNAVGNLINK TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCSUPLRMATLTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCSUPLRMATLTP_STR-MANDT sy-vline
WA_CCSUPLRMATLTP_STR-CHMLSUPLRMATLUUID sy-vline
WA_CCSUPLRMATLTP_STR-ACTIVECHMLSUPLRMATLUUID sy-vline
WA_CCSUPLRMATLTP_STR-RESPONSIBLEUNIT sy-vline
WA_CCSUPLRMATLTP_STR-RESPONSIBLEUNITNAME sy-vline
WA_CCSUPLRMATLTP_STR-CHMLSUPLRMATLNAME sy-vline
WA_CCSUPLRMATLTP_STR-SUPPLIERMATERIALNUMBER sy-vline
WA_CCSUPLRMATLTP_STR-CHMLCMPLNCINFOUUID sy-vline
WA_CCSUPLRMATLTP_STR-CHMLCMPLNCINFONAVGNLINK sy-vline
WA_CCSUPLRMATLTP_STR-CHMLCMPLNCINFOCOMBINEDNAME sy-vline
WA_CCSUPLRMATLTP_STR-BUSINESSPARTNERSUPPLIER sy-vline
WA_CCSUPLRMATLTP_STR-SUPPLIERNAME sy-vline
WA_CCSUPLRMATLTP_STR-SUPPLIERMATERIALCOMBINEDNAME sy-vline
WA_CCSUPLRMATLTP_STR-CHMLSUPLRMATLDATASTATUS sy-vline
WA_CCSUPLRMATLTP_STR-CHMLSUPLRMATLDATASTATUSNAME sy-vline
WA_CCSUPLRMATLTP_STR-CHMLSUPLRMATLDATASTSCRITLTY sy-vline
WA_CCSUPLRMATLTP_STR-CHMLSUPLRMATLSUPLRSTS sy-vline
WA_CCSUPLRMATLTP_STR-CHMLSUPLRMATLSUPLRSTSNAME sy-vline
WA_CCSUPLRMATLTP_STR-CHMLSUPLRMATLSUPLRSTSCRITLTY sy-vline
WA_CCSUPLRMATLTP_STR-LASTCHANGEDBYUSER sy-vline
WA_CCSUPLRMATLTP_STR-LASTCHANGEDBYUSERNAME sy-vline
WA_CCSUPLRMATLTP_STR-CHMLSUPLRMATLISOUTDATED sy-vline
WA_CCSUPLRMATLTP_STR-LASTCHANGEUTCDATETIME sy-vline
WA_CCSUPLRMATLTP_STR-CHMLCOMPOSITIONUUID sy-vline
WA_CCSUPLRMATLTP_STR-CHMLCMPSTNINPROCSTATUS sy-vline
WA_CCSUPLRMATLTP_STR-CHMLCMPSTNRELDSTATUS sy-vline
WA_CCSUPLRMATLTP_STR-CHMLCOMPOSITIONNAVGNLINK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.