ABAP Select data from SAP table CCS_AENR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCS_AENR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCS_AENR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCS_AENR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCS_AENR TYPE STANDARD TABLE OF CCS_AENR,
      WA_CCS_AENR TYPE CCS_AENR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCS_AENR> TYPE CCS_AENR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCS_AENR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCS_AENR
  INTO TABLE IT_CCS_AENR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCS_AENR
*  INTO TABLE @DATA(IT_CCS_AENR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCS_AENR INDEX 1 INTO DATA(WA_CCS_AENR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCS_AENR ASSIGNING <CCS_AENR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCS_AENR>-MANDT = 1.
<CCS_AENR>-AENNR = 1.
<CCS_AENR>-AENST = 1.
<CCS_AENR>-AENBE = 1.
<CCS_AENR>-DATUV = 1.
ENDLOOP.

LOOP AT IT_CCS_AENR INTO WA_CCS_AENR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCS_AENR-TECHV, sy-vline,
WA_CCS_AENR-ANDAT, sy-vline,
WA_CCS_AENR-ANNAM, sy-vline,
WA_CCS_AENR-AEDAT, sy-vline,
WA_CCS_AENR-AENAM, sy-vline,
WA_CCS_AENR-AETXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCS_AENR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCS_AENR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCS_AENR INTO WA_CCS_AENR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCS_AENR-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCS_AENR-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LTXSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_CCS_AENR-LTXSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCS_AENR-LTXSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AEPAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCS_AENR-AEPAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCS_AENR-AEPAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCS_AENR_STR,
MANDT TYPE STRING,
AENNR TYPE STRING,
AENST TYPE STRING,
AENBE TYPE STRING,
DATUV TYPE STRING,
TECHV TYPE STRING,
ANDAT TYPE STRING,
ANNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
AETXT TYPE STRING,
LTXSP TYPE STRING,
AEGRU TYPE STRING,
CCART TYPE STRING,
CCSTM TYPE STRING,
DYDAT TYPE STRING,
CONT1 TYPE STRING,
AEFUN TYPE STRING,
UESTR TYPE STRING,
RLKEY TYPE STRING,
LVORM TYPE STRING,
CLINT TYPE STRING,
AERNG TYPE STRING,
RLDAT TYPE STRING,
RLTIM TYPE STRING,
TEREL TYPE STRING,
NACHT TYPE STRING,
INDAT TYPE STRING,
AUDAT TYPE STRING,
FLUSE TYPE STRING,
AEDIF TYPE STRING,
ERLED TYPE STRING,
LASTCHANGEDDATETIME TYPE STRING,
AEPAR TYPE STRING,
AESTX TYPE STRING,
CC12T TYPE STRING,
EFFTYP TYPE STRING,
STA_SY_CUR_KEY TYPE STRING,
STA_SY_CUR_TXT TYPE STRING,
USERNAME TYPE STRING,
STA_DATE TYPE STRING,
STA_TIME TYPE STRING,
DURATION TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCS_AENR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCS_AENR_STR-MANDT sy-vline
WA_CCS_AENR_STR-AENNR sy-vline
WA_CCS_AENR_STR-AENST sy-vline
WA_CCS_AENR_STR-AENBE sy-vline
WA_CCS_AENR_STR-DATUV sy-vline
WA_CCS_AENR_STR-TECHV sy-vline
WA_CCS_AENR_STR-ANDAT sy-vline
WA_CCS_AENR_STR-ANNAM sy-vline
WA_CCS_AENR_STR-AEDAT sy-vline
WA_CCS_AENR_STR-AENAM sy-vline
WA_CCS_AENR_STR-AETXT sy-vline
WA_CCS_AENR_STR-LTXSP sy-vline
WA_CCS_AENR_STR-AEGRU sy-vline
WA_CCS_AENR_STR-CCART sy-vline
WA_CCS_AENR_STR-CCSTM sy-vline
WA_CCS_AENR_STR-DYDAT sy-vline
WA_CCS_AENR_STR-CONT1 sy-vline
WA_CCS_AENR_STR-AEFUN sy-vline
WA_CCS_AENR_STR-UESTR sy-vline
WA_CCS_AENR_STR-RLKEY sy-vline
WA_CCS_AENR_STR-LVORM sy-vline
WA_CCS_AENR_STR-CLINT sy-vline
WA_CCS_AENR_STR-AERNG sy-vline
WA_CCS_AENR_STR-RLDAT sy-vline
WA_CCS_AENR_STR-RLTIM sy-vline
WA_CCS_AENR_STR-TEREL sy-vline
WA_CCS_AENR_STR-NACHT sy-vline
WA_CCS_AENR_STR-INDAT sy-vline
WA_CCS_AENR_STR-AUDAT sy-vline
WA_CCS_AENR_STR-FLUSE sy-vline
WA_CCS_AENR_STR-AEDIF sy-vline
WA_CCS_AENR_STR-ERLED sy-vline
WA_CCS_AENR_STR-LASTCHANGEDDATETIME sy-vline
WA_CCS_AENR_STR-AEPAR sy-vline
WA_CCS_AENR_STR-AESTX sy-vline
WA_CCS_AENR_STR-CC12T sy-vline
WA_CCS_AENR_STR-EFFTYP sy-vline
WA_CCS_AENR_STR-STA_SY_CUR_KEY sy-vline
WA_CCS_AENR_STR-STA_SY_CUR_TXT sy-vline
WA_CCS_AENR_STR-USERNAME sy-vline
WA_CCS_AENR_STR-STA_DATE sy-vline
WA_CCS_AENR_STR-STA_TIME sy-vline
WA_CCS_AENR_STR-DURATION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.