ABAP Select data from SAP table CCRCS_REGCHECK_LOG_MFLE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCRCS_REGCHECK_LOG_MFLE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCRCS_REGCHECK_LOG_MFLE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCRCS_REGCHECK_LOG_MFLE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCRCS_REGCHECK_LOG_MFLE TYPE STANDARD TABLE OF CCRCS_REGCHECK_LOG_MFLE,
      WA_CCRCS_REGCHECK_LOG_MFLE TYPE CCRCS_REGCHECK_LOG_MFLE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCRCS_REGCHECK_LOG_MFLE> TYPE CCRCS_REGCHECK_LOG_MFLE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCRCS_REGCHECK_LOG_MFLE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCRCS_REGCHECK_LOG_MFLE
  INTO TABLE IT_CCRCS_REGCHECK_LOG_MFLE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCRCS_REGCHECK_LOG_MFLE
*  INTO TABLE @DATA(IT_CCRCS_REGCHECK_LOG_MFLE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCRCS_REGCHECK_LOG_MFLE INDEX 1 INTO DATA(WA_CCRCS_REGCHECK_LOG_MFLE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCRCS_REGCHECK_LOG_MFLE ASSIGNING <CCRCS_REGCHECK_LOG_MFLE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCRCS_REGCHECK_LOG_MFLE>-MATNR = 1.
<CCRCS_REGCHECK_LOG_MFLE>-VBELN = 1.
<CCRCS_REGCHECK_LOG_MFLE>-POSNR = 1.
<CCRCS_REGCHECK_LOG_MFLE>-COUNTRY_DELIVERY = 1.
<CCRCS_REGCHECK_LOG_MFLE>-LEGAL_LIST = 1.
ENDLOOP.

LOOP AT IT_CCRCS_REGCHECK_LOG_MFLE INTO WA_CCRCS_REGCHECK_LOG_MFLE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCRCS_REGCHECK_LOG_MFLE-SUBID, sy-vline,
WA_CCRCS_REGCHECK_LOG_MFLE-STATUS, sy-vline,
WA_CCRCS_REGCHECK_LOG_MFLE-OBJNR, sy-vline,
WA_CCRCS_REGCHECK_LOG_MFLE-VKORG, sy-vline,
WA_CCRCS_REGCHECK_LOG_MFLE-KUNNR, sy-vline,
WA_CCRCS_REGCHECK_LOG_MFLE-WERK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCRCS_REGCHECK_LOG_MFLE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCRCS_REGCHECK_LOG_MFLE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCRCS_REGCHECK_LOG_MFLE INTO WA_CCRCS_REGCHECK_LOG_MFLE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN5, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN5_OUTPUT' EXPORTING input = WA_CCRCS_REGCHECK_LOG_MFLE-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCRCS_REGCHECK_LOG_MFLE-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCRCS_REGCHECK_LOG_MFLE-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCRCS_REGCHECK_LOG_MFLE-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPEC1, internal->external for field SUBID CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_CCRCS_REGCHECK_LOG_MFLE-SUBID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCRCS_REGCHECK_LOG_MFLE-SUBID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STATUS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCRCS_REGCHECK_LOG_MFLE-STATUS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCRCS_REGCHECK_LOG_MFLE-STATUS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCRCS_REGCHECK_LOG_MFLE-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCRCS_REGCHECK_LOG_MFLE-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR_LONG CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CCRCS_REGCHECK_LOG_MFLE-MATNR_LONG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCRCS_REGCHECK_LOG_MFLE-MATNR_LONG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCRCS_REGCHECK_LOG_MFLE_STR,
MATNR TYPE STRING,
VBELN TYPE STRING,
POSNR TYPE STRING,
COUNTRY_DELIVERY TYPE STRING,
LEGAL_LIST TYPE STRING,
SUBID TYPE STRING,
STATUS TYPE STRING,
OBJNR TYPE STRING,
VKORG TYPE STRING,
KUNNR TYPE STRING,
WERK TYPE STRING,
MSGNO TYPE STRING,
MSGID TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,
ARKTX TYPE STRING,
MATNR_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCRCS_REGCHECK_LOG_MFLE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-MATNR sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-VBELN sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-POSNR sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-COUNTRY_DELIVERY sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-LEGAL_LIST sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-SUBID sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-STATUS sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-OBJNR sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-VKORG sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-KUNNR sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-WERK sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-MSGNO sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-MSGID sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-MSGV1 sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-MSGV2 sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-MSGV3 sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-MSGV4 sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-ARKTX sy-vline
WA_CCRCS_REGCHECK_LOG_MFLE_STR-MATNR_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.