ABAP Select data from SAP table CCM_RSTUNE50_06_ALV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCM_RSTUNE50_06_ALV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCM_RSTUNE50_06_ALV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCM_RSTUNE50_06_ALV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCM_RSTUNE50_06_ALV TYPE STANDARD TABLE OF CCM_RSTUNE50_06_ALV,
      WA_CCM_RSTUNE50_06_ALV TYPE CCM_RSTUNE50_06_ALV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCM_RSTUNE50_06_ALV> TYPE CCM_RSTUNE50_06_ALV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCM_RSTUNE50_06_ALV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCM_RSTUNE50_06_ALV
  INTO TABLE IT_CCM_RSTUNE50_06_ALV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCM_RSTUNE50_06_ALV
*  INTO TABLE @DATA(IT_CCM_RSTUNE50_06_ALV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCM_RSTUNE50_06_ALV INDEX 1 INTO DATA(WA_CCM_RSTUNE50_06_ALV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCM_RSTUNE50_06_ALV ASSIGNING <CCM_RSTUNE50_06_ALV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCM_RSTUNE50_06_ALV>-DINDEX = 1.
<CCM_RSTUNE50_06_ALV>-NAME = 1.
<CCM_RSTUNE50_06_ALV>-ATTACHED = 1.
<CCM_RSTUNE50_06_ALV>-MEMSUM = 1.
<CCM_RSTUNE50_06_ALV>-PRIVSUM = 1.
ENDLOOP.

LOOP AT IT_CCM_RSTUNE50_06_ALV INTO WA_CCM_RSTUNE50_06_ALV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCM_RSTUNE50_06_ALV-IMODEG, sy-vline,
WA_CCM_RSTUNE50_06_ALV-EMODEG, sy-vline,
WA_CCM_RSTUNE50_06_ALV-MTAB10, sy-vline,
WA_CCM_RSTUNE50_06_ALV-MTAB11, sy-vline,
WA_CCM_RSTUNE50_06_ALV-MTAB12, sy-vline,
WA_CCM_RSTUNE50_06_ALV-MTAB13, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCM_RSTUNE50_06_ALV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCM_RSTUNE50_06_ALV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCM_RSTUNE50_06_ALV INTO WA_CCM_RSTUNE50_06_ALV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCM_RSTUNE50_06_ALV_STR,
DINDEX TYPE STRING,
NAME TYPE STRING,
ATTACHED TYPE STRING,
MEMSUM TYPE STRING,
PRIVSUM TYPE STRING,
IMODEG TYPE STRING,
EMODEG TYPE STRING,
MTAB10 TYPE STRING,
MTAB11 TYPE STRING,
MTAB12 TYPE STRING,
MTAB13 TYPE STRING,
MTAB14 TYPE STRING,
MTAB15 TYPE STRING,
MTAB16 TYPE STRING,
MTAB17 TYPE STRING,
MTAB18 TYPE STRING,
MTAB19 TYPE STRING,
HARDLIMIT TYPE STRING,
WPTYPE TYPE STRING,
LIMIT_EXTENDED TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCM_RSTUNE50_06_ALV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-DINDEX sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-NAME sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-ATTACHED sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-MEMSUM sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-PRIVSUM sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-IMODEG sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-EMODEG sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-MTAB10 sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-MTAB11 sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-MTAB12 sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-MTAB13 sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-MTAB14 sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-MTAB15 sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-MTAB16 sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-MTAB17 sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-MTAB18 sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-MTAB19 sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-HARDLIMIT sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-WPTYPE sy-vline
WA_CCM_RSTUNE50_06_ALV_STR-LIMIT_EXTENDED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.