ABAP Select data from SAP table CCIHS_WAPTIOT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCIHS_WAPTIOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCIHS_WAPTIOT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCIHS_WAPTIOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCIHS_WAPTIOT TYPE STANDARD TABLE OF CCIHS_WAPTIOT,
      WA_CCIHS_WAPTIOT TYPE CCIHS_WAPTIOT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCIHS_WAPTIOT> TYPE CCIHS_WAPTIOT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCIHS_WAPTIOT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCIHS_WAPTIOT
  INTO TABLE IT_CCIHS_WAPTIOT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCIHS_WAPTIOT
*  INTO TABLE @DATA(IT_CCIHS_WAPTIOT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCIHS_WAPTIOT INDEX 1 INTO DATA(WA_CCIHS_WAPTIOT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCIHS_WAPTIOT ASSIGNING <CCIHS_WAPTIOT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCIHS_WAPTIOT>-MARKFLG = 1.
<CCIHS_WAPTIOT>-SELEFLG = 1.
<CCIHS_WAPTIOT>-LINENO = 1.
<CCIHS_WAPTIOT>-LINEMOD = 1.
<CCIHS_WAPTIOT>-CHCOFLG = 1.
ENDLOOP.

LOOP AT IT_CCIHS_WAPTIOT INTO WA_CCIHS_WAPTIOT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCIHS_WAPTIOT-LOCKMOD, sy-vline,
WA_CCIHS_WAPTIOT-INTRFLG, sy-vline,
WA_CCIHS_WAPTIOT-MANDT, sy-vline,
WA_CCIHS_WAPTIOT-RECN, sy-vline,
WA_CCIHS_WAPTIOT-ACTN, sy-vline,
WA_CCIHS_WAPTIOT-VALFR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCIHS_WAPTIOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCIHS_WAPTIOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCIHS_WAPTIOT INTO WA_CCIHS_WAPTIOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAPTIOT-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAPTIOT-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAPTIOT-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAPTIOT-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAPTIOT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAPTIOT-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAPTIOT-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAPTIOT-OWNID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAPTIOT-RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAPTIOT-RECNROOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNTWAH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAPTIOT-RECNTWAH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAPTIOT-RECNTWAH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNTPT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAPTIOT-RECNTPT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAPTIOT-RECNTPT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CHRID, internal->external for field WAID CALL FUNCTION 'CONVERSION_EXIT_CHRID_OUTPUT' EXPORTING input = WA_CCIHS_WAPTIOT-WAID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAPTIOT-WAID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCIHS_WAPTIOT_STR,
MARKFLG TYPE STRING,
SELEFLG TYPE STRING,
LINENO TYPE STRING,
LINEMOD TYPE STRING,
CHCOFLG TYPE STRING,
LOCKMOD TYPE STRING,
INTRFLG TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
RECNTWAH TYPE STRING,
RECNTPT TYPE STRING,
PTNAM TYPE STRING,
WANAM TYPE STRING,
WAID TYPE STRING,
WATYPE TYPE STRING,
WATYPENAM TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCIHS_WAPTIOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCIHS_WAPTIOT_STR-MARKFLG sy-vline
WA_CCIHS_WAPTIOT_STR-SELEFLG sy-vline
WA_CCIHS_WAPTIOT_STR-LINENO sy-vline
WA_CCIHS_WAPTIOT_STR-LINEMOD sy-vline
WA_CCIHS_WAPTIOT_STR-CHCOFLG sy-vline
WA_CCIHS_WAPTIOT_STR-LOCKMOD sy-vline
WA_CCIHS_WAPTIOT_STR-INTRFLG sy-vline
WA_CCIHS_WAPTIOT_STR-MANDT sy-vline
WA_CCIHS_WAPTIOT_STR-RECN sy-vline
WA_CCIHS_WAPTIOT_STR-ACTN sy-vline
WA_CCIHS_WAPTIOT_STR-VALFR sy-vline
WA_CCIHS_WAPTIOT_STR-VALTO sy-vline
WA_CCIHS_WAPTIOT_STR-AENNR sy-vline
WA_CCIHS_WAPTIOT_STR-DELFLG sy-vline
WA_CCIHS_WAPTIOT_STR-PARKFLG sy-vline
WA_CCIHS_WAPTIOT_STR-CRDAT sy-vline
WA_CCIHS_WAPTIOT_STR-CRNAM sy-vline
WA_CCIHS_WAPTIOT_STR-UPDDAT sy-vline
WA_CCIHS_WAPTIOT_STR-UPDNAM sy-vline
WA_CCIHS_WAPTIOT_STR-SRSID sy-vline
WA_CCIHS_WAPTIOT_STR-OWNID sy-vline
WA_CCIHS_WAPTIOT_STR-RECNROOT sy-vline
WA_CCIHS_WAPTIOT_STR-RECNTWAH sy-vline
WA_CCIHS_WAPTIOT_STR-RECNTPT sy-vline
WA_CCIHS_WAPTIOT_STR-PTNAM sy-vline
WA_CCIHS_WAPTIOT_STR-WANAM sy-vline
WA_CCIHS_WAPTIOT_STR-WAID sy-vline
WA_CCIHS_WAPTIOT_STR-WATYPE sy-vline
WA_CCIHS_WAPTIOT_STR-WATYPENAM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.