ABAP Select data from SAP table CCIHS_WAFLIOT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCIHS_WAFLIOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCIHS_WAFLIOT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCIHS_WAFLIOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCIHS_WAFLIOT TYPE STANDARD TABLE OF CCIHS_WAFLIOT,
      WA_CCIHS_WAFLIOT TYPE CCIHS_WAFLIOT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCIHS_WAFLIOT> TYPE CCIHS_WAFLIOT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCIHS_WAFLIOT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCIHS_WAFLIOT
  INTO TABLE IT_CCIHS_WAFLIOT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCIHS_WAFLIOT
*  INTO TABLE @DATA(IT_CCIHS_WAFLIOT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCIHS_WAFLIOT INDEX 1 INTO DATA(WA_CCIHS_WAFLIOT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCIHS_WAFLIOT ASSIGNING <CCIHS_WAFLIOT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCIHS_WAFLIOT>-MARKFLG = 1.
<CCIHS_WAFLIOT>-SELEFLG = 1.
<CCIHS_WAFLIOT>-LINENO = 1.
<CCIHS_WAFLIOT>-LINEMOD = 1.
<CCIHS_WAFLIOT>-CHCOFLG = 1.
ENDLOOP.

LOOP AT IT_CCIHS_WAFLIOT INTO WA_CCIHS_WAFLIOT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCIHS_WAFLIOT-LOCKMOD, sy-vline,
WA_CCIHS_WAFLIOT-INTRFLG, sy-vline,
WA_CCIHS_WAFLIOT-MANDT, sy-vline,
WA_CCIHS_WAFLIOT-RECN, sy-vline,
WA_CCIHS_WAFLIOT-ACTN, sy-vline,
WA_CCIHS_WAFLIOT-TPLNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCIHS_WAFLIOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCIHS_WAFLIOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCIHS_WAFLIOT INTO WA_CCIHS_WAFLIOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAFLIOT-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAFLIOT-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_WAFLIOT-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_WAFLIOT-ACTN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCIHS_WAFLIOT_STR,
MARKFLG TYPE STRING,
SELEFLG TYPE STRING,
LINENO TYPE STRING,
LINEMOD TYPE STRING,
CHCOFLG TYPE STRING,
LOCKMOD TYPE STRING,
INTRFLG TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
TPLNR TYPE STRING,
TPLKZ TYPE STRING,
FLTYP TYPE STRING,
PLTXT TYPE STRING,
FLPLANT TYPE STRING,
STRNO TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCIHS_WAFLIOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCIHS_WAFLIOT_STR-MARKFLG sy-vline
WA_CCIHS_WAFLIOT_STR-SELEFLG sy-vline
WA_CCIHS_WAFLIOT_STR-LINENO sy-vline
WA_CCIHS_WAFLIOT_STR-LINEMOD sy-vline
WA_CCIHS_WAFLIOT_STR-CHCOFLG sy-vline
WA_CCIHS_WAFLIOT_STR-LOCKMOD sy-vline
WA_CCIHS_WAFLIOT_STR-INTRFLG sy-vline
WA_CCIHS_WAFLIOT_STR-MANDT sy-vline
WA_CCIHS_WAFLIOT_STR-RECN sy-vline
WA_CCIHS_WAFLIOT_STR-ACTN sy-vline
WA_CCIHS_WAFLIOT_STR-TPLNR sy-vline
WA_CCIHS_WAFLIOT_STR-TPLKZ sy-vline
WA_CCIHS_WAFLIOT_STR-FLTYP sy-vline
WA_CCIHS_WAFLIOT_STR-PLTXT sy-vline
WA_CCIHS_WAFLIOT_STR-FLPLANT sy-vline
WA_CCIHS_WAFLIOT_STR-STRNO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.