ABAP Select data from SAP table CCIHS_PTSEL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCIHS_PTSEL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCIHS_PTSEL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCIHS_PTSEL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCIHS_PTSEL TYPE STANDARD TABLE OF CCIHS_PTSEL,
      WA_CCIHS_PTSEL TYPE CCIHS_PTSEL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCIHS_PTSEL> TYPE CCIHS_PTSEL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCIHS_PTSEL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCIHS_PTSEL
  INTO TABLE IT_CCIHS_PTSEL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCIHS_PTSEL
*  INTO TABLE @DATA(IT_CCIHS_PTSEL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCIHS_PTSEL INDEX 1 INTO DATA(WA_CCIHS_PTSEL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCIHS_PTSEL ASSIGNING <CCIHS_PTSEL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCIHS_PTSEL>-MANDT = 1.
<CCIHS_PTSEL>-WAID = 1.
<CCIHS_PTSEL>-WAVERS = 1.
<CCIHS_PTSEL>-WASTAT = 1.
<CCIHS_PTSEL>-WASHSTATNAM = 1.
ENDLOOP.

LOOP AT IT_CCIHS_PTSEL INTO WA_CCIHS_PTSEL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCIHS_PTSEL-WASTATNAM, sy-vline,
WA_CCIHS_PTSEL-WATYPE, sy-vline,
WA_CCIHS_PTSEL-WATYPENAM, sy-vline,
WA_CCIHS_PTSEL-WANAM, sy-vline,
WA_CCIHS_PTSEL-AUTHGRP, sy-vline,
WA_CCIHS_PTSEL-AUTHNAM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCIHS_PTSEL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCIHS_PTSEL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCIHS_PTSEL INTO WA_CCIHS_PTSEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CHRID, internal->external for field WAID CALL FUNCTION 'CONVERSION_EXIT_CHRID_OUTPUT' EXPORTING input = WA_CCIHS_PTSEL-WAID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_PTSEL-WAID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_PTSEL-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_PTSEL-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CCIHS_PTSEL-VERSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCIHS_PTSEL-VERSNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCIHS_PTSEL_STR,
MANDT TYPE STRING,
WAID TYPE STRING,
WAVERS TYPE STRING,
WASTAT TYPE STRING,
WASHSTATNAM TYPE STRING,
WASTATNAM TYPE STRING,
WATYPE TYPE STRING,
WATYPENAM TYPE STRING,
WANAM TYPE STRING,
AUTHGRP TYPE STRING,
AUTHNAM TYPE STRING,
WAPLANT TYPE STRING,
WAPLANTNAM TYPE STRING,
AENNR TYPE STRING,
VALDAT TYPE STRING,
VERSFLAG TYPE STRING,
VERSNR TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
SEARCHMODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCIHS_PTSEL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCIHS_PTSEL_STR-MANDT sy-vline
WA_CCIHS_PTSEL_STR-WAID sy-vline
WA_CCIHS_PTSEL_STR-WAVERS sy-vline
WA_CCIHS_PTSEL_STR-WASTAT sy-vline
WA_CCIHS_PTSEL_STR-WASHSTATNAM sy-vline
WA_CCIHS_PTSEL_STR-WASTATNAM sy-vline
WA_CCIHS_PTSEL_STR-WATYPE sy-vline
WA_CCIHS_PTSEL_STR-WATYPENAM sy-vline
WA_CCIHS_PTSEL_STR-WANAM sy-vline
WA_CCIHS_PTSEL_STR-AUTHGRP sy-vline
WA_CCIHS_PTSEL_STR-AUTHNAM sy-vline
WA_CCIHS_PTSEL_STR-WAPLANT sy-vline
WA_CCIHS_PTSEL_STR-WAPLANTNAM sy-vline
WA_CCIHS_PTSEL_STR-AENNR sy-vline
WA_CCIHS_PTSEL_STR-VALDAT sy-vline
WA_CCIHS_PTSEL_STR-VERSFLAG sy-vline
WA_CCIHS_PTSEL_STR-VERSNR sy-vline
WA_CCIHS_PTSEL_STR-VALFR sy-vline
WA_CCIHS_PTSEL_STR-VALTO sy-vline
WA_CCIHS_PTSEL_STR-SEARCHMODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.