ABAP Select data from SAP table CCGLS_SERIOT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCGLS_SERIOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCGLS_SERIOT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCGLS_SERIOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCGLS_SERIOT TYPE STANDARD TABLE OF CCGLS_SERIOT,
      WA_CCGLS_SERIOT TYPE CCGLS_SERIOT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCGLS_SERIOT> TYPE CCGLS_SERIOT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCGLS_SERIOT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCGLS_SERIOT
  INTO TABLE IT_CCGLS_SERIOT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCGLS_SERIOT
*  INTO TABLE @DATA(IT_CCGLS_SERIOT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCGLS_SERIOT INDEX 1 INTO DATA(WA_CCGLS_SERIOT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCGLS_SERIOT ASSIGNING <CCGLS_SERIOT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCGLS_SERIOT>-MARKFLG = 1.
<CCGLS_SERIOT>-SELEFLG = 1.
<CCGLS_SERIOT>-LINENO = 1.
<CCGLS_SERIOT>-LINEMOD = 1.
<CCGLS_SERIOT>-CHCOFLG = 1.
ENDLOOP.

LOOP AT IT_CCGLS_SERIOT INTO WA_CCGLS_SERIOT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCGLS_SERIOT-LOCKMOD, sy-vline,
WA_CCGLS_SERIOT-INTRFLG, sy-vline,
WA_CCGLS_SERIOT-LSYTYPE, sy-vline,
WA_CCGLS_SERIOT-LSYID, sy-vline,
WA_CCGLS_SERIOT-FLGBARCODE, sy-vline,
WA_CCGLS_SERIOT-START, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCGLS_SERIOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCGLS_SERIOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCGLS_SERIOT INTO WA_CCGLS_SERIOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCGLS_SERIOT_STR,
MARKFLG TYPE STRING,
SELEFLG TYPE STRING,
LINENO TYPE STRING,
LINEMOD TYPE STRING,
CHCOFLG TYPE STRING,
LOCKMOD TYPE STRING,
INTRFLG TYPE STRING,
LSYTYPE TYPE STRING,
LSYID TYPE STRING,
FLGBARCODE TYPE STRING,
START TYPE STRING,
INCREMENT TYPE STRING,
REPETITION TYPE STRING,
LSYNAM TYPE STRING,
INVISIBLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCGLS_SERIOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCGLS_SERIOT_STR-MARKFLG sy-vline
WA_CCGLS_SERIOT_STR-SELEFLG sy-vline
WA_CCGLS_SERIOT_STR-LINENO sy-vline
WA_CCGLS_SERIOT_STR-LINEMOD sy-vline
WA_CCGLS_SERIOT_STR-CHCOFLG sy-vline
WA_CCGLS_SERIOT_STR-LOCKMOD sy-vline
WA_CCGLS_SERIOT_STR-INTRFLG sy-vline
WA_CCGLS_SERIOT_STR-LSYTYPE sy-vline
WA_CCGLS_SERIOT_STR-LSYID sy-vline
WA_CCGLS_SERIOT_STR-FLGBARCODE sy-vline
WA_CCGLS_SERIOT_STR-START sy-vline
WA_CCGLS_SERIOT_STR-INCREMENT sy-vline
WA_CCGLS_SERIOT_STR-REPETITION sy-vline
WA_CCGLS_SERIOT_STR-LSYNAM sy-vline
WA_CCGLS_SERIOT_STR-INVISIBLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.