ABAP Select data from SAP table CCCWASTECODETP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCCWASTECODETP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCCWASTECODETP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCCWASTECODETP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCCWASTECODETP TYPE STANDARD TABLE OF CCCWASTECODETP,
      WA_CCCWASTECODETP TYPE CCCWASTECODETP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCCWASTECODETP> TYPE CCCWASTECODETP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCCWASTECODETP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCCWASTECODETP
  INTO TABLE IT_CCCWASTECODETP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCCWASTECODETP
*  INTO TABLE @DATA(IT_CCCWASTECODETP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCCWASTECODETP INDEX 1 INTO DATA(WA_CCCWASTECODETP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCCWASTECODETP ASSIGNING <CCCWASTECODETP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCCWASTECODETP>-MANDT = 1.
<CCCWASTECODETP>-CHMLCMPLNCWASTECODEUUID = 1.
<CCCWASTECODETP>-CHMLCMPLNCINFOUUID = 1.
<CCCWASTECODETP>-CREATIONUTCDATETIME = 1.
<CCCWASTECODETP>-CREATEDBYUSER = 1.
ENDLOOP.

LOOP AT IT_CCCWASTECODETP INTO WA_CCCWASTECODETP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCCWASTECODETP-LASTCHANGEUTCDATETIME, sy-vline,
WA_CCCWASTECODETP-LASTCHANGEDBYUSER, sy-vline,
WA_CCCWASTECODETP-CHMLCMPLNCINFOCOMBINEDNAME, sy-vline,
WA_CCCWASTECODETP-MATERIAL, sy-vline,
WA_CCCWASTECODETP-CHMLCMPLNCINTERNALNAME, sy-vline,
WA_CCCWASTECODETP-SPECIFICATION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCCWASTECODETP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCCWASTECODETP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCCWASTECODETP INTO WA_CCCWASTECODETP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CCCWASTECODETP-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCCWASTECODETP-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPEC1, internal->external for field SPECIFICATION CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_CCCWASTECODETP-SPECIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCCWASTECODETP-SPECIFICATION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCCWASTECODETP_STR,
MANDT TYPE STRING,
CHMLCMPLNCWASTECODEUUID TYPE STRING,
CHMLCMPLNCINFOUUID TYPE STRING,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
CHMLCMPLNCINFOCOMBINEDNAME TYPE STRING,
MATERIAL TYPE STRING,
CHMLCMPLNCINTERNALNAME TYPE STRING,
SPECIFICATION TYPE STRING,
ANALYTICCMPSTNNAVGNLINKUUID TYPE STRING,
PCPHYSPRPTYNAVGNLINKUUID TYPE STRING,
ADDLPRPTYNAVGNLINKUUID TYPE STRING,
CHMLCMPLNCPRODISRESEARCHED TYPE STRING,
MATERIALISDISPOSED TYPE STRING,
MATERIALISEMISSIONRELEVANT TYPE STRING,
MATERIALISPRODUCED TYPE STRING,
MATERIALISSOLD TYPE STRING,
MATERIALISSOURCED TYPE STRING,
MATERIALISTRANSPORTED TYPE STRING,
CHMLCMPLNCINFOTYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCCWASTECODETP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCCWASTECODETP_STR-MANDT sy-vline
WA_CCCWASTECODETP_STR-CHMLCMPLNCWASTECODEUUID sy-vline
WA_CCCWASTECODETP_STR-CHMLCMPLNCINFOUUID sy-vline
WA_CCCWASTECODETP_STR-CREATIONUTCDATETIME sy-vline
WA_CCCWASTECODETP_STR-CREATEDBYUSER sy-vline
WA_CCCWASTECODETP_STR-LASTCHANGEUTCDATETIME sy-vline
WA_CCCWASTECODETP_STR-LASTCHANGEDBYUSER sy-vline
WA_CCCWASTECODETP_STR-CHMLCMPLNCINFOCOMBINEDNAME sy-vline
WA_CCCWASTECODETP_STR-MATERIAL sy-vline
WA_CCCWASTECODETP_STR-CHMLCMPLNCINTERNALNAME sy-vline
WA_CCCWASTECODETP_STR-SPECIFICATION sy-vline
WA_CCCWASTECODETP_STR-ANALYTICCMPSTNNAVGNLINKUUID sy-vline
WA_CCCWASTECODETP_STR-PCPHYSPRPTYNAVGNLINKUUID sy-vline
WA_CCCWASTECODETP_STR-ADDLPRPTYNAVGNLINKUUID sy-vline
WA_CCCWASTECODETP_STR-CHMLCMPLNCPRODISRESEARCHED sy-vline
WA_CCCWASTECODETP_STR-MATERIALISDISPOSED sy-vline
WA_CCCWASTECODETP_STR-MATERIALISEMISSIONRELEVANT sy-vline
WA_CCCWASTECODETP_STR-MATERIALISPRODUCED sy-vline
WA_CCCWASTECODETP_STR-MATERIALISSOLD sy-vline
WA_CCCWASTECODETP_STR-MATERIALISSOURCED sy-vline
WA_CCCWASTECODETP_STR-MATERIALISTRANSPORTED sy-vline
WA_CCCWASTECODETP_STR-CHMLCMPLNCINFOTYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.