ABAP Select data from SAP table CCCSCT1_GET_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCCSCT1_GET_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCCSCT1_GET_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CCCSCT1_GET_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CCCSCT1_GET_DATA TYPE STANDARD TABLE OF CCCSCT1_GET_DATA, WA_CCCSCT1_GET_DATA TYPE CCCSCT1_GET_DATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CCCSCT1_GET_DATA> TYPE CCCSCT1_GET_DATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CCCSCT1_GET_DATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CCCSCT1_GET_DATA INTO TABLE IT_CCCSCT1_GET_DATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CCCSCT1_GET_DATA * INTO TABLE @DATA(IT_CCCSCT1_GET_DATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CCCSCT1_GET_DATA INDEX 1 INTO DATA(WA_CCCSCT1_GET_DATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CCCSCT1_GET_DATA ASSIGNING <CCCSCT1_GET_DATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCCSCT1_GET_DATA>-CONTROLLER = 1.
<CCCSCT1_GET_DATA>-ET_BOX_COMPRESSED = 1.
<CCCSCT1_GET_DATA>-CONTROLLER = 1.
<CCCSCT1_GET_DATA>-ITEM = 1.
<CCCSCT1_GET_DATA>-IT_HEADER = 1.
ENDLOOP. LOOP AT IT_CCCSCT1_GET_DATA INTO WA_CCCSCT1_GET_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CCCSCT1_GET_DATA-CONTROLLER, sy-vline,
WA_CCCSCT1_GET_DATA-ITEM, sy-vline,
WA_CCCSCT1_GET_DATA-IT_HEADER_VIEW, sy-vline,
WA_CCCSCT1_GET_DATA-CONTROLLER, sy-vline,
WA_CCCSCT1_GET_DATA-ITEM, sy-vline,
WA_CCCSCT1_GET_DATA-IT_KEYLIST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCCSCT1_GET_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCCSCT1_GET_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCCSCT1_GET_DATA INTO WA_CCCSCT1_GET_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCCSCT1_GET_DATA_STR,
CONTROLLER TYPE STRING,
ET_BOX_COMPRESSED TYPE STRING,
CONTROLLER TYPE STRING,
ITEM TYPE STRING,
IT_HEADER TYPE STRING,
CONTROLLER TYPE STRING,
ITEM TYPE STRING,
IT_HEADER_VIEW TYPE STRING,
CONTROLLER TYPE STRING,
ITEM TYPE STRING,
IT_KEYLIST TYPE STRING,
CONTROLLER TYPE STRING,
ITEM TYPE STRING,
IT_NAMTAB_VIEW TYPE STRING,
CONTROLLER TYPE STRING,
ITEM TYPE STRING,
IT_SELLIST TYPE STRING,
CONTROLLER TYPE STRING,
ITEM TYPE STRING,
IV_CALLED_FROM_SM30 TYPE STRING,
IV_CHECK_LINEDEP_AUTH TYPE STRING,
IV_OBJECT_NAME TYPE STRING,
IV_OBJECT_TYPE TYPE STRING,
IV_SELECT_BY_KEYLIST TYPE STRING,
IV_VIEWNAME TYPE STRING,
IV_VIEW_TABLE_FLAG TYPE STRING,
IV_VIEW_VARIANT TYPE STRING,
IV_WITHOUT_EXITS TYPE STRING,
IV_WITHOUT_SUBSET TYPE STRING,
IV_WITH_AUTHORITY_CHECK TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCCSCT1_GET_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCCSCT1_GET_DATA_STR-CONTROLLER sy-vline
WA_CCCSCT1_GET_DATA_STR-ET_BOX_COMPRESSED sy-vline
WA_CCCSCT1_GET_DATA_STR-CONTROLLER sy-vline
WA_CCCSCT1_GET_DATA_STR-ITEM sy-vline
WA_CCCSCT1_GET_DATA_STR-IT_HEADER sy-vline
WA_CCCSCT1_GET_DATA_STR-CONTROLLER sy-vline
WA_CCCSCT1_GET_DATA_STR-ITEM sy-vline
WA_CCCSCT1_GET_DATA_STR-IT_HEADER_VIEW sy-vline
WA_CCCSCT1_GET_DATA_STR-CONTROLLER sy-vline
WA_CCCSCT1_GET_DATA_STR-ITEM sy-vline
WA_CCCSCT1_GET_DATA_STR-IT_KEYLIST sy-vline
WA_CCCSCT1_GET_DATA_STR-CONTROLLER sy-vline
WA_CCCSCT1_GET_DATA_STR-ITEM sy-vline
WA_CCCSCT1_GET_DATA_STR-IT_NAMTAB_VIEW sy-vline
WA_CCCSCT1_GET_DATA_STR-CONTROLLER sy-vline
WA_CCCSCT1_GET_DATA_STR-ITEM sy-vline
WA_CCCSCT1_GET_DATA_STR-IT_SELLIST sy-vline
WA_CCCSCT1_GET_DATA_STR-CONTROLLER sy-vline
WA_CCCSCT1_GET_DATA_STR-ITEM sy-vline
WA_CCCSCT1_GET_DATA_STR-IV_CALLED_FROM_SM30 sy-vline
WA_CCCSCT1_GET_DATA_STR-IV_CHECK_LINEDEP_AUTH sy-vline
WA_CCCSCT1_GET_DATA_STR-IV_OBJECT_NAME sy-vline
WA_CCCSCT1_GET_DATA_STR-IV_OBJECT_TYPE sy-vline
WA_CCCSCT1_GET_DATA_STR-IV_SELECT_BY_KEYLIST sy-vline
WA_CCCSCT1_GET_DATA_STR-IV_VIEWNAME sy-vline
WA_CCCSCT1_GET_DATA_STR-IV_VIEW_TABLE_FLAG sy-vline
WA_CCCSCT1_GET_DATA_STR-IV_VIEW_VARIANT sy-vline
WA_CCCSCT1_GET_DATA_STR-IV_WITHOUT_EXITS sy-vline
WA_CCCSCT1_GET_DATA_STR-IV_WITHOUT_SUBSET sy-vline
WA_CCCSCT1_GET_DATA_STR-IV_WITH_AUTHORITY_CHECK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.