ABAP Select data from SAP table CCCIASGDPRPTY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCCIASGDPRPTY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCCIASGDPRPTY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCCIASGDPRPTY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCCIASGDPRPTY TYPE STANDARD TABLE OF CCCIASGDPRPTY,
      WA_CCCIASGDPRPTY TYPE CCCIASGDPRPTY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCCIASGDPRPTY> TYPE CCCIASGDPRPTY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCCIASGDPRPTY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCCIASGDPRPTY
  INTO TABLE IT_CCCIASGDPRPTY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCCIASGDPRPTY
*  INTO TABLE @DATA(IT_CCCIASGDPRPTY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCCIASGDPRPTY INDEX 1 INTO DATA(WA_CCCIASGDPRPTY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCCIASGDPRPTY ASSIGNING <CCCIASGDPRPTY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCCIASGDPRPTY>-MANDT = 1.
<CCCIASGDPRPTY>-CHMLCMPLNCINFOUUID = 1.
<CCCIASGDPRPTY>-PCPRPTYROOTTYPE = 1.
<CCCIASGDPRPTY>-PCPRPTYROOTTYPENAME = 1.
<CCCIASGDPRPTY>-PCPRPTYPROCGSTS = 1.
ENDLOOP.

LOOP AT IT_CCCIASGDPRPTY INTO WA_CCCIASGDPRPTY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCCIASGDPRPTY-PCPRPTYPROCGSTSTEXT, sy-vline,
WA_CCCIASGDPRPTY-PCPRPTYPROCGSTSCRITLTY, sy-vline,
WA_CCCIASGDPRPTY-PCPRPTYNAVGNLINKUUID, sy-vline,
WA_CCCIASGDPRPTY-PCPRPTYISACTIVE, sy-vline,
WA_CCCIASGDPRPTY-SEMANTICOBJECT, sy-vline,
WA_CCCIASGDPRPTY-SEMANTICOBJECTACTION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCCIASGDPRPTY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCCIASGDPRPTY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCCIASGDPRPTY INTO WA_CCCIASGDPRPTY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCCIASGDPRPTY_STR,
MANDT TYPE STRING,
CHMLCMPLNCINFOUUID TYPE STRING,
PCPRPTYROOTTYPE TYPE STRING,
PCPRPTYROOTTYPENAME TYPE STRING,
PCPRPTYPROCGSTS TYPE STRING,
PCPRPTYPROCGSTSTEXT TYPE STRING,
PCPRPTYPROCGSTSCRITLTY TYPE STRING,
PCPRPTYNAVGNLINKUUID TYPE STRING,
PCPRPTYISACTIVE TYPE STRING,
SEMANTICOBJECT TYPE STRING,
SEMANTICOBJECTACTION TYPE STRING,
PCPRPTYNAVGNLINKPARAMNAME TYPE STRING,
PCPRPTYACTIVEINDPARAMNAME TYPE STRING,
PCPRPTYINPROCESSUUID TYPE STRING,
PCPRPTYINPROCPROCGSTS TYPE STRING,
PCPRPTYINPROCISACTIVE TYPE STRING,
PCPRPTYRELEASEDUUID TYPE STRING,
PCPRPTYRELDPROCGSTS TYPE STRING,
PCPRPTYRELDISACTIVE TYPE STRING,
MATERIALISPRODUCED TYPE STRING,
MATERIALISSOLD TYPE STRING,
MATERIALISTRANSPORTED TYPE STRING,
MATERIALISSOURCED TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCCIASGDPRPTY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCCIASGDPRPTY_STR-MANDT sy-vline
WA_CCCIASGDPRPTY_STR-CHMLCMPLNCINFOUUID sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYROOTTYPE sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYROOTTYPENAME sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYPROCGSTS sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYPROCGSTSTEXT sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYPROCGSTSCRITLTY sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYNAVGNLINKUUID sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYISACTIVE sy-vline
WA_CCCIASGDPRPTY_STR-SEMANTICOBJECT sy-vline
WA_CCCIASGDPRPTY_STR-SEMANTICOBJECTACTION sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYNAVGNLINKPARAMNAME sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYACTIVEINDPARAMNAME sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYINPROCESSUUID sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYINPROCPROCGSTS sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYINPROCISACTIVE sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYRELEASEDUUID sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYRELDPROCGSTS sy-vline
WA_CCCIASGDPRPTY_STR-PCPRPTYRELDISACTIVE sy-vline
WA_CCCIASGDPRPTY_STR-MATERIALISPRODUCED sy-vline
WA_CCCIASGDPRPTY_STR-MATERIALISSOLD sy-vline
WA_CCCIASGDPRPTY_STR-MATERIALISTRANSPORTED sy-vline
WA_CCCIASGDPRPTY_STR-MATERIALISSOURCED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.