ABAP Select data from SAP table CCAPEVALWCUTHORZ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CCAPEVALWCUTHORZ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CCAPEVALWCUTHORZ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CCAPEVALWCUTHORZ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CCAPEVALWCUTHORZ TYPE STANDARD TABLE OF CCAPEVALWCUTHORZ,
      WA_CCAPEVALWCUTHORZ TYPE CCAPEVALWCUTHORZ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CCAPEVALWCUTHORZ> TYPE CCAPEVALWCUTHORZ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CCAPEVALWCUTHORZ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CCAPEVALWCUTHORZ
  INTO TABLE IT_CCAPEVALWCUTHORZ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CCAPEVALWCUTHORZ
*  INTO TABLE @DATA(IT_CCAPEVALWCUTHORZ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CCAPEVALWCUTHORZ INDEX 1 INTO DATA(WA_CCAPEVALWCUTHORZ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CCAPEVALWCUTHORZ ASSIGNING <CCAPEVALWCUTHORZ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CCAPEVALWCUTHORZ>-MANDT = 1.
<CCAPEVALWCUTHORZ>-WORKCENTERINTERNALID = 1.
<CCAPEVALWCUTHORZ>-WORKCENTERTYPECODE = 1.
<CCAPEVALWCUTHORZ>-CAPACITYCATEGORYALLOCATION = 1.
<CCAPEVALWCUTHORZ>-CAPACITYINTERNALID = 1.
ENDLOOP.

LOOP AT IT_CCAPEVALWCUTHORZ INTO WA_CCAPEVALWCUTHORZ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CCAPEVALWCUTHORZ-CAPACITYEVALUATIONTIMEPERIODWK, sy-vline,
WA_CCAPEVALWCUTHORZ-CAPACITYEVALUATIONTIMEPERIOD, sy-vline,
WA_CCAPEVALWCUTHORZ-SHIFTNAME, sy-vline,
WA_CCAPEVALWCUTHORZ-WORKCENTER, sy-vline,
WA_CCAPEVALWCUTHORZ-WORKCENTEREVALUATIONHORIZON, sy-vline,
WA_CCAPEVALWCUTHORZ-CAPACITYREQUIREMENTORIGIN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CCAPEVALWCUTHORZ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CCAPEVALWCUTHORZ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CCAPEVALWCUTHORZ INTO WA_CCAPEVALWCUTHORZ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field BASEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CCAPEVALWCUTHORZ-BASEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCAPEVALWCUTHORZ-BASEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WORKCENTERCAPACITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CCAPEVALWCUTHORZ-WORKCENTERCAPACITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CCAPEVALWCUTHORZ-WORKCENTERCAPACITYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CCAPEVALWCUTHORZ_STR,
MANDT TYPE STRING,
WORKCENTERINTERNALID TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,
CAPACITYCATEGORYALLOCATION TYPE STRING,
CAPACITYINTERNALID TYPE STRING,
CAPACITYEVALUATIONTIMEPERIODWK TYPE STRING,
CAPACITYEVALUATIONTIMEPERIOD TYPE STRING,
SHIFTNAME TYPE STRING,
WORKCENTER TYPE STRING,
WORKCENTEREVALUATIONHORIZON TYPE STRING,
CAPACITYREQUIREMENTORIGIN TYPE STRING,
OPERATIONPLANNINGSTATUSCODE TYPE STRING,
ORDERSTATUSCODE TYPE STRING,
WORKCENTERTOTUTILZNINTMEPERD TYPE STRING,
WORKCENTERUTILZNINHOURS TYPE STRING,
BASEUNIT TYPE STRING,
WORKCENTERCAPUTILZNVALUECOLOR TYPE STRING,
WORKCENTERCAPCUMLTVVALUECOLOR TYPE STRING,
WORKCENTERCUMLTVLOADINTMEPERD TYPE STRING,
WORKCENTERCUMLTVLOADINHOURS TYPE STRING,
CURRENTPLANTDATE TYPE STRING,
WORKCENTERAVAILABLECAPACITY TYPE STRING,
WORKCENTERCAPACITYUNIT TYPE STRING,
HORIZONSTARTDATE TYPE STRING,
HORIZONENDDATE TYPE STRING,
CAPEVALSTARTDATE TYPE STRING,
CAPEVALBUCKETTYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CCAPEVALWCUTHORZ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CCAPEVALWCUTHORZ_STR-MANDT sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTERINTERNALID sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTERTYPECODE sy-vline
WA_CCAPEVALWCUTHORZ_STR-CAPACITYCATEGORYALLOCATION sy-vline
WA_CCAPEVALWCUTHORZ_STR-CAPACITYINTERNALID sy-vline
WA_CCAPEVALWCUTHORZ_STR-CAPACITYEVALUATIONTIMEPERIODWK sy-vline
WA_CCAPEVALWCUTHORZ_STR-CAPACITYEVALUATIONTIMEPERIOD sy-vline
WA_CCAPEVALWCUTHORZ_STR-SHIFTNAME sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTER sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTEREVALUATIONHORIZON sy-vline
WA_CCAPEVALWCUTHORZ_STR-CAPACITYREQUIREMENTORIGIN sy-vline
WA_CCAPEVALWCUTHORZ_STR-OPERATIONPLANNINGSTATUSCODE sy-vline
WA_CCAPEVALWCUTHORZ_STR-ORDERSTATUSCODE sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTERTOTUTILZNINTMEPERD sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTERUTILZNINHOURS sy-vline
WA_CCAPEVALWCUTHORZ_STR-BASEUNIT sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTERCAPUTILZNVALUECOLOR sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTERCAPCUMLTVVALUECOLOR sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTERCUMLTVLOADINTMEPERD sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTERCUMLTVLOADINHOURS sy-vline
WA_CCAPEVALWCUTHORZ_STR-CURRENTPLANTDATE sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTERAVAILABLECAPACITY sy-vline
WA_CCAPEVALWCUTHORZ_STR-WORKCENTERCAPACITYUNIT sy-vline
WA_CCAPEVALWCUTHORZ_STR-HORIZONSTARTDATE sy-vline
WA_CCAPEVALWCUTHORZ_STR-HORIZONENDDATE sy-vline
WA_CCAPEVALWCUTHORZ_STR-CAPEVALSTARTDATE sy-vline
WA_CCAPEVALWCUTHORZ_STR-CAPEVALBUCKETTYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.