ABAP Select data from SAP table CC1TEV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CC1TEV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CC1TEV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CC1TEV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CC1TEV TYPE STANDARD TABLE OF CC1TEV,
      WA_CC1TEV TYPE CC1TEV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CC1TEV> TYPE CC1TEV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CC1TEV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CC1TEV
  INTO TABLE IT_CC1TEV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CC1TEV
*  INTO TABLE @DATA(IT_CC1TEV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CC1TEV INDEX 1 INTO DATA(WA_CC1TEV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CC1TEV ASSIGNING <CC1TEV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CC1TEV>-MANDT = 1.
<CC1TEV>-PDSNR = 1.
<CC1TEV>-PERNR = 1.
<CC1TEV>-ZAUSW = 1.
<CC1TEV>-LDATE = 1.
ENDLOOP.

LOOP AT IT_CC1TEV INTO WA_CC1TEV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CC1TEV-LTIME, sy-vline,
WA_CC1TEV-ERDAT, sy-vline,
WA_CC1TEV-ERTIM, sy-vline,
WA_CC1TEV-SATZA, sy-vline,
WA_CC1TEV-TERID, sy-vline,
WA_CC1TEV-ABWGR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CC1TEV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CC1TEV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CC1TEV INTO WA_CC1TEV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit DALLF, internal->external for field DALLF CALL FUNCTION 'CONVERSION_EXIT_DALLF_OUTPUT' EXPORTING input = WA_CC1TEV-DALLF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CC1TEV-DALLF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CC1TEV-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CC1TEV-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CC1TEV-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CC1TEV-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field POSID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_CC1TEV-POSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CC1TEV-POSID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NPLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CC1TEV-NPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CC1TEV-NPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CC1TEV-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CC1TEV-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CC1TEV-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CC1TEV-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRZNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CC1TEV-PRZNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CC1TEV-PRZNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SKOST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CC1TEV-SKOST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CC1TEV-SKOST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CC1TEV_STR,
MANDT TYPE STRING,
PDSNR TYPE STRING,
PERNR TYPE STRING,
ZAUSW TYPE STRING,
LDATE TYPE STRING,
LTIME TYPE STRING,
ERDAT TYPE STRING,
ERTIM TYPE STRING,
SATZA TYPE STRING,
TERID TYPE STRING,
ABWGR TYPE STRING,
ORIGF TYPE STRING,
DALLF TYPE STRING,
PDC_OTYPE TYPE STRING,
PDC_PLANS TYPE STRING,
OTYPE TYPE STRING,
PLANS TYPE STRING,
PDC_USRUP TYPE STRING,
USER2 TYPE STRING,
INDEU TYPE STRING,
BUKRS TYPE STRING,
GSBER TYPE STRING,
KOSTL TYPE STRING,
LTLST TYPE STRING,
AUFNR TYPE STRING,
KSTRG TYPE STRING,
POSID TYPE STRING,
NPLNR TYPE STRING,
VORNR TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
PRZNR TYPE STRING,
FISTL TYPE STRING,
GEBER TYPE STRING,
SKOST TYPE STRING,
SBUKR TYPE STRING,
SGSBR TYPE STRING,
SGTXT TYPE STRING,
DART TYPE STRING,
UDART TYPE STRING,
BUDGET_PD TYPE STRING,
TRFGR TYPE STRING,
TRFST TYPE STRING,
PRAKN TYPE STRING,
PRAKZ TYPE STRING,
AUFKZ TYPE STRING,
BWGRL TYPE STRING,
WAERS TYPE STRING,END OF T_EKKO_STR. DATA: WA_CC1TEV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CC1TEV_STR-MANDT sy-vline
WA_CC1TEV_STR-PDSNR sy-vline
WA_CC1TEV_STR-PERNR sy-vline
WA_CC1TEV_STR-ZAUSW sy-vline
WA_CC1TEV_STR-LDATE sy-vline
WA_CC1TEV_STR-LTIME sy-vline
WA_CC1TEV_STR-ERDAT sy-vline
WA_CC1TEV_STR-ERTIM sy-vline
WA_CC1TEV_STR-SATZA sy-vline
WA_CC1TEV_STR-TERID sy-vline
WA_CC1TEV_STR-ABWGR sy-vline
WA_CC1TEV_STR-ORIGF sy-vline
WA_CC1TEV_STR-DALLF sy-vline
WA_CC1TEV_STR-PDC_OTYPE sy-vline
WA_CC1TEV_STR-PDC_PLANS sy-vline
WA_CC1TEV_STR-OTYPE sy-vline
WA_CC1TEV_STR-PLANS sy-vline
WA_CC1TEV_STR-PDC_USRUP sy-vline
WA_CC1TEV_STR-USER2 sy-vline
WA_CC1TEV_STR-INDEU sy-vline
WA_CC1TEV_STR-BUKRS sy-vline
WA_CC1TEV_STR-GSBER sy-vline
WA_CC1TEV_STR-KOSTL sy-vline
WA_CC1TEV_STR-LTLST sy-vline
WA_CC1TEV_STR-AUFNR sy-vline
WA_CC1TEV_STR-KSTRG sy-vline
WA_CC1TEV_STR-POSID sy-vline
WA_CC1TEV_STR-NPLNR sy-vline
WA_CC1TEV_STR-VORNR sy-vline
WA_CC1TEV_STR-KDAUF sy-vline
WA_CC1TEV_STR-KDPOS sy-vline
WA_CC1TEV_STR-PRZNR sy-vline
WA_CC1TEV_STR-FISTL sy-vline
WA_CC1TEV_STR-GEBER sy-vline
WA_CC1TEV_STR-SKOST sy-vline
WA_CC1TEV_STR-SBUKR sy-vline
WA_CC1TEV_STR-SGSBR sy-vline
WA_CC1TEV_STR-SGTXT sy-vline
WA_CC1TEV_STR-DART sy-vline
WA_CC1TEV_STR-UDART sy-vline
WA_CC1TEV_STR-BUDGET_PD sy-vline
WA_CC1TEV_STR-TRFGR sy-vline
WA_CC1TEV_STR-TRFST sy-vline
WA_CC1TEV_STR-PRAKN sy-vline
WA_CC1TEV_STR-PRAKZ sy-vline
WA_CC1TEV_STR-AUFKZ sy-vline
WA_CC1TEV_STR-BWGRL sy-vline
WA_CC1TEV_STR-WAERS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.