ABAP Select data from SAP table C_TCURV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP C_TCURV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to C_TCURV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the C_TCURV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_C_TCURV TYPE STANDARD TABLE OF C_TCURV,
      WA_C_TCURV TYPE C_TCURV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <C_TCURV> TYPE C_TCURV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_C_TCURV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM C_TCURV
  INTO TABLE IT_C_TCURV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM C_TCURV
*  INTO TABLE @DATA(IT_C_TCURV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_C_TCURV INDEX 1 INTO DATA(WA_C_TCURV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_C_TCURV ASSIGNING <C_TCURV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<C_TCURV>-MANDT = 1.
<C_TCURV>-KURST = 1.
<C_TCURV>-XINVR = 1.
<C_TCURV>-BWAER = 1.
<C_TCURV>-XBWRL = 1.
ENDLOOP.

LOOP AT IT_C_TCURV INTO WA_C_TCURV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_C_TCURV-GKUZU, sy-vline,
WA_C_TCURV-BKUZU, sy-vline,
WA_C_TCURV-XFIXD, sy-vline,
WA_C_TCURV-XEURO, sy-vline,
WA_C_TCURV-XNORL, sy-vline,
ENDLOOP. *Add any further fields from structure WA_C_TCURV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_C_TCURV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_C_TCURV INTO WA_C_TCURV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_C_TCURV_STR,
MANDT TYPE STRING,
KURST TYPE STRING,
XINVR TYPE STRING,
BWAER TYPE STRING,
XBWRL TYPE STRING,
GKUZU TYPE STRING,
BKUZU TYPE STRING,
XFIXD TYPE STRING,
XEURO TYPE STRING,
XNORL TYPE STRING,END OF T_EKKO_STR. DATA: WA_C_TCURV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_C_TCURV_STR-MANDT sy-vline
WA_C_TCURV_STR-KURST sy-vline
WA_C_TCURV_STR-XINVR sy-vline
WA_C_TCURV_STR-BWAER sy-vline
WA_C_TCURV_STR-XBWRL sy-vline
WA_C_TCURV_STR-GKUZU sy-vline
WA_C_TCURV_STR-BKUZU sy-vline
WA_C_TCURV_STR-XFIXD sy-vline
WA_C_TCURV_STR-XEURO sy-vline
WA_C_TCURV_STR-XNORL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.