ABAP Select data from SAP table BWE_0PM_ORDER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BWE_0PM_ORDER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BWE_0PM_ORDER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BWE_0PM_ORDER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BWE_0PM_ORDER TYPE STANDARD TABLE OF BWE_0PM_ORDER,
      WA_BWE_0PM_ORDER TYPE BWE_0PM_ORDER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BWE_0PM_ORDER> TYPE BWE_0PM_ORDER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BWE_0PM_ORDER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BWE_0PM_ORDER
  INTO TABLE IT_BWE_0PM_ORDER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BWE_0PM_ORDER
*  INTO TABLE @DATA(IT_BWE_0PM_ORDER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BWE_0PM_ORDER INDEX 1 INTO DATA(WA_BWE_0PM_ORDER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BWE_0PM_ORDER ASSIGNING <BWE_0PM_ORDER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BWE_0PM_ORDER>-AUFNR = 1.
<BWE_0PM_ORDER>-AUART = 1.
<BWE_0PM_ORDER>-EQUNR = 1.
<BWE_0PM_ORDER>-BAUTL = 1.
<BWE_0PM_ORDER>-IWERK = 1.
ENDLOOP.

LOOP AT IT_BWE_0PM_ORDER INTO WA_BWE_0PM_ORDER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BWE_0PM_ORDER-INGRP, sy-vline,
WA_BWE_0PM_ORDER-ARBPL, sy-vline,
WA_BWE_0PM_ORDER-WERKS, sy-vline,
WA_BWE_0PM_ORDER-REVNR, sy-vline,
WA_BWE_0PM_ORDER-ILART, sy-vline,
WA_BWE_0PM_ORDER-TPLNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BWE_0PM_ORDER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BWE_0PM_ORDER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BWE_0PM_ORDER INTO WA_BWE_0PM_ORDER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BAUTL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-BAUTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-BAUTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-ANLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-ANLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLUN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-ANLUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-ANLUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-QMNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PROID CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-PROID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-PROID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WAPOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-WAPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-WAPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COORD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-COORD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-COORD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field POSID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_BWE_0PM_ORDER-POSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BWE_0PM_ORDER-POSID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BWE_0PM_ORDER_STR,
AUFNR TYPE STRING,
AUART TYPE STRING,
EQUNR TYPE STRING,
BAUTL TYPE STRING,
IWERK TYPE STRING,
INGRP TYPE STRING,
ARBPL TYPE STRING,
WERKS TYPE STRING,
REVNR TYPE STRING,
ILART TYPE STRING,
TPLNR TYPE STRING,
ABCKZ TYPE STRING,
SWERK TYPE STRING,
STORT TYPE STRING,
MSGRP TYPE STRING,
BEBER TYPE STRING,
GSBER TYPE STRING,
KOKRS TYPE STRING,
KOSTL TYPE STRING,
BUKRS TYPE STRING,
ANLNR TYPE STRING,
ANLUN TYPE STRING,
OBJNR TYPE STRING,
BWSTSYS0 TYPE STRING,
ERDAT TYPE STRING,
AEDAT TYPE STRING,
QMNUM TYPE STRING,
PROID TYPE STRING,
PLKNZ TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
WAPOS TYPE STRING,
USER4 TYPE STRING,
WAERS TYPE STRING,
COORD TYPE STRING,
POSID TYPE STRING,END OF T_EKKO_STR. DATA: WA_BWE_0PM_ORDER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BWE_0PM_ORDER_STR-AUFNR sy-vline
WA_BWE_0PM_ORDER_STR-AUART sy-vline
WA_BWE_0PM_ORDER_STR-EQUNR sy-vline
WA_BWE_0PM_ORDER_STR-BAUTL sy-vline
WA_BWE_0PM_ORDER_STR-IWERK sy-vline
WA_BWE_0PM_ORDER_STR-INGRP sy-vline
WA_BWE_0PM_ORDER_STR-ARBPL sy-vline
WA_BWE_0PM_ORDER_STR-WERKS sy-vline
WA_BWE_0PM_ORDER_STR-REVNR sy-vline
WA_BWE_0PM_ORDER_STR-ILART sy-vline
WA_BWE_0PM_ORDER_STR-TPLNR sy-vline
WA_BWE_0PM_ORDER_STR-ABCKZ sy-vline
WA_BWE_0PM_ORDER_STR-SWERK sy-vline
WA_BWE_0PM_ORDER_STR-STORT sy-vline
WA_BWE_0PM_ORDER_STR-MSGRP sy-vline
WA_BWE_0PM_ORDER_STR-BEBER sy-vline
WA_BWE_0PM_ORDER_STR-GSBER sy-vline
WA_BWE_0PM_ORDER_STR-KOKRS sy-vline
WA_BWE_0PM_ORDER_STR-KOSTL sy-vline
WA_BWE_0PM_ORDER_STR-BUKRS sy-vline
WA_BWE_0PM_ORDER_STR-ANLNR sy-vline
WA_BWE_0PM_ORDER_STR-ANLUN sy-vline
WA_BWE_0PM_ORDER_STR-OBJNR sy-vline
WA_BWE_0PM_ORDER_STR-BWSTSYS0 sy-vline
WA_BWE_0PM_ORDER_STR-ERDAT sy-vline
WA_BWE_0PM_ORDER_STR-AEDAT sy-vline
WA_BWE_0PM_ORDER_STR-QMNUM sy-vline
WA_BWE_0PM_ORDER_STR-PROID sy-vline
WA_BWE_0PM_ORDER_STR-PLKNZ sy-vline
WA_BWE_0PM_ORDER_STR-PLNTY sy-vline
WA_BWE_0PM_ORDER_STR-PLNNR sy-vline
WA_BWE_0PM_ORDER_STR-PLNAL sy-vline
WA_BWE_0PM_ORDER_STR-WAPOS sy-vline
WA_BWE_0PM_ORDER_STR-USER4 sy-vline
WA_BWE_0PM_ORDER_STR-WAERS sy-vline
WA_BWE_0PM_ORDER_STR-COORD sy-vline
WA_BWE_0PM_ORDER_STR-POSID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.