ABAP Select data from SAP table BUT050_TD_SRC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BUT050_TD_SRC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BUT050_TD_SRC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BUT050_TD_SRC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BUT050_TD_SRC TYPE STANDARD TABLE OF BUT050_TD_SRC,
      WA_BUT050_TD_SRC TYPE BUT050_TD_SRC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BUT050_TD_SRC> TYPE BUT050_TD_SRC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BUT050_TD_SRC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BUT050_TD_SRC
  INTO TABLE IT_BUT050_TD_SRC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BUT050_TD_SRC
*  INTO TABLE @DATA(IT_BUT050_TD_SRC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BUT050_TD_SRC INDEX 1 INTO DATA(WA_BUT050_TD_SRC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BUT050_TD_SRC ASSIGNING <BUT050_TD_SRC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BUT050_TD_SRC>-CLIENT = 1.
<BUT050_TD_SRC>-SOURCE_SYSTEM = 1.
<BUT050_TD_SRC>-SOURCE_ID = 1.
<BUT050_TD_SRC>-DATE_TO = 1.
<BUT050_TD_SRC>-DATE_FROM = 1.
ENDLOOP.

LOOP AT IT_BUT050_TD_SRC INTO WA_BUT050_TD_SRC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BUT050_TD_SRC-RELTYP, sy-vline,
WA_BUT050_TD_SRC-XRF, sy-vline,
WA_BUT050_TD_SRC-DFTVAL, sy-vline,
WA_BUT050_TD_SRC-RLTYP, sy-vline,
WA_BUT050_TD_SRC-RELKIND, sy-vline,
WA_BUT050_TD_SRC-CRUSR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BUT050_TD_SRC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BUT050_TD_SRC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BUT050_TD_SRC INTO WA_BUT050_TD_SRC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BUT050_TD_SRC_STR,
CLIENT TYPE STRING,
SOURCE_SYSTEM TYPE STRING,
SOURCE_ID TYPE STRING,
DATE_TO TYPE STRING,
DATE_FROM TYPE STRING,
RELTYP TYPE STRING,
XRF TYPE STRING,
DFTVAL TYPE STRING,
RLTYP TYPE STRING,
RELKIND TYPE STRING,
CRUSR TYPE STRING,
CRDAT TYPE STRING,
CRTIM TYPE STRING,
CHUSR TYPE STRING,
CHDAT TYPE STRING,
CHTIM TYPE STRING,
XDFREL TYPE STRING,
XDFREL2 TYPE STRING,
DB_KEY TYPE STRING,
DB_KEY_TD TYPE STRING,
SOURCE_RECENCY TYPE STRING,END OF T_EKKO_STR. DATA: WA_BUT050_TD_SRC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BUT050_TD_SRC_STR-CLIENT sy-vline
WA_BUT050_TD_SRC_STR-SOURCE_SYSTEM sy-vline
WA_BUT050_TD_SRC_STR-SOURCE_ID sy-vline
WA_BUT050_TD_SRC_STR-DATE_TO sy-vline
WA_BUT050_TD_SRC_STR-DATE_FROM sy-vline
WA_BUT050_TD_SRC_STR-RELTYP sy-vline
WA_BUT050_TD_SRC_STR-XRF sy-vline
WA_BUT050_TD_SRC_STR-DFTVAL sy-vline
WA_BUT050_TD_SRC_STR-RLTYP sy-vline
WA_BUT050_TD_SRC_STR-RELKIND sy-vline
WA_BUT050_TD_SRC_STR-CRUSR sy-vline
WA_BUT050_TD_SRC_STR-CRDAT sy-vline
WA_BUT050_TD_SRC_STR-CRTIM sy-vline
WA_BUT050_TD_SRC_STR-CHUSR sy-vline
WA_BUT050_TD_SRC_STR-CHDAT sy-vline
WA_BUT050_TD_SRC_STR-CHTIM sy-vline
WA_BUT050_TD_SRC_STR-XDFREL sy-vline
WA_BUT050_TD_SRC_STR-XDFREL2 sy-vline
WA_BUT050_TD_SRC_STR-DB_KEY sy-vline
WA_BUT050_TD_SRC_STR-DB_KEY_TD sy-vline
WA_BUT050_TD_SRC_STR-SOURCE_RECENCY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.