ABAP Select data from SAP table BUS_BP_RELATIONS_BW_470 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BUS_BP_RELATIONS_BW_470 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BUS_BP_RELATIONS_BW_470. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BUS_BP_RELATIONS_BW_470 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BUS_BP_RELATIONS_BW_470 TYPE STANDARD TABLE OF BUS_BP_RELATIONS_BW_470,
      WA_BUS_BP_RELATIONS_BW_470 TYPE BUS_BP_RELATIONS_BW_470,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BUS_BP_RELATIONS_BW_470> TYPE BUS_BP_RELATIONS_BW_470.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BUS_BP_RELATIONS_BW_470.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BUS_BP_RELATIONS_BW_470
  INTO TABLE IT_BUS_BP_RELATIONS_BW_470.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BUS_BP_RELATIONS_BW_470
*  INTO TABLE @DATA(IT_BUS_BP_RELATIONS_BW_4702).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BUS_BP_RELATIONS_BW_470 INDEX 1 INTO DATA(WA_BUS_BP_RELATIONS_BW_4702).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BUS_BP_RELATIONS_BW_470 ASSIGNING <BUS_BP_RELATIONS_BW_470>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BUS_BP_RELATIONS_BW_470>-CLIENT = 1.
<BUS_BP_RELATIONS_BW_470>-RELNR = 1.
<BUS_BP_RELATIONS_BW_470>-PARTNER1 = 1.
<BUS_BP_RELATIONS_BW_470>-PARTNER2 = 1.
<BUS_BP_RELATIONS_BW_470>-PARTNER1_GUID = 1.
ENDLOOP.

LOOP AT IT_BUS_BP_RELATIONS_BW_470 INTO WA_BUS_BP_RELATIONS_BW_470.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BUS_BP_RELATIONS_BW_470-PARTNER2_GUID, sy-vline,
WA_BUS_BP_RELATIONS_BW_470-RELDIR, sy-vline,
WA_BUS_BP_RELATIONS_BW_470-RELTYP, sy-vline,
WA_BUS_BP_RELATIONS_BW_470-DATE_TO, sy-vline,
WA_BUS_BP_RELATIONS_BW_470-DATE_FROM, sy-vline,
WA_BUS_BP_RELATIONS_BW_470-PAFKT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BUS_BP_RELATIONS_BW_470 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BUS_BP_RELATIONS_BW_470 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BUS_BP_RELATIONS_BW_470 INTO WA_BUS_BP_RELATIONS_BW_470. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BUS_BP_RELATIONS_BW_470-RELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BUS_BP_RELATIONS_BW_470-RELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTNER1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BUS_BP_RELATIONS_BW_470-PARTNER1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BUS_BP_RELATIONS_BW_470-PARTNER1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTNER2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BUS_BP_RELATIONS_BW_470-PARTNER2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BUS_BP_RELATIONS_BW_470-PARTNER2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SXIDN, internal->external for field SMTP_ADDR CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_BUS_BP_RELATIONS_BW_470-SMTP_ADDR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BUS_BP_RELATIONS_BW_470-SMTP_ADDR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BUS_BP_RELATIONS_BW_470_STR,
CLIENT TYPE STRING,
RELNR TYPE STRING,
PARTNER1 TYPE STRING,
PARTNER2 TYPE STRING,
PARTNER1_GUID TYPE STRING,
PARTNER2_GUID TYPE STRING,
RELDIR TYPE STRING,
RELTYP TYPE STRING,
DATE_TO TYPE STRING,
DATE_FROM TYPE STRING,
PAFKT TYPE STRING,
ABTNR TYPE STRING,
PAAUTH TYPE STRING,
PAVIP TYPE STRING,
COUNTRY TYPE STRING,
POST_CODE1 TYPE STRING,
CITY1 TYPE STRING,
STREET TYPE STRING,
HOUSE_NUM1 TYPE STRING,
TEL_NUMBER TYPE STRING,
FAX_NUMBER TYPE STRING,
SMTP_ADDR TYPE STRING,
CMPY_PART_PER TYPE STRING,
CMPY_PART_AMO TYPE STRING,
CMPY_PART_CUR TYPE STRING,
CMPY_CONTROL TYPE STRING,
ADDR_SHORT TYPE STRING,
ADDR_SHORT_S TYPE STRING,
LINE0 TYPE STRING,
LINE1 TYPE STRING,
LINE2 TYPE STRING,
LINE3 TYPE STRING,
LINE4 TYPE STRING,
LINE5 TYPE STRING,
LINE6 TYPE STRING,
LINE7 TYPE STRING,
LINE8 TYPE STRING,
LINE9 TYPE STRING,
FLG_DELETED TYPE STRING,
DQ_ONLINE_UPDATE TYPE STRING,
DQ_OFFLINE_UPDATE TYPE STRING,
DQ_TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_BUS_BP_RELATIONS_BW_470_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-CLIENT sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-RELNR sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-PARTNER1 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-PARTNER2 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-PARTNER1_GUID sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-PARTNER2_GUID sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-RELDIR sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-RELTYP sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-DATE_TO sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-DATE_FROM sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-PAFKT sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-ABTNR sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-PAAUTH sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-PAVIP sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-COUNTRY sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-POST_CODE1 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-CITY1 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-STREET sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-HOUSE_NUM1 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-TEL_NUMBER sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-FAX_NUMBER sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-SMTP_ADDR sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-CMPY_PART_PER sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-CMPY_PART_AMO sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-CMPY_PART_CUR sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-CMPY_CONTROL sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-ADDR_SHORT sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-ADDR_SHORT_S sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-LINE0 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-LINE1 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-LINE2 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-LINE3 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-LINE4 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-LINE5 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-LINE6 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-LINE7 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-LINE8 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-LINE9 sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-FLG_DELETED sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-DQ_ONLINE_UPDATE sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-DQ_OFFLINE_UPDATE sy-vline
WA_BUS_BP_RELATIONS_BW_470_STR-DQ_TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.