ABAP Select data from SAP table BUMP_S_GENERALCTRL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BUMP_S_GENERALCTRL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BUMP_S_GENERALCTRL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BUMP_S_GENERALCTRL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BUMP_S_GENERALCTRL TYPE STANDARD TABLE OF BUMP_S_GENERALCTRL,
      WA_BUMP_S_GENERALCTRL TYPE BUMP_S_GENERALCTRL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BUMP_S_GENERALCTRL> TYPE BUMP_S_GENERALCTRL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BUMP_S_GENERALCTRL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BUMP_S_GENERALCTRL
  INTO TABLE IT_BUMP_S_GENERALCTRL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BUMP_S_GENERALCTRL
*  INTO TABLE @DATA(IT_BUMP_S_GENERALCTRL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BUMP_S_GENERALCTRL INDEX 1 INTO DATA(WA_BUMP_S_GENERALCTRL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BUMP_S_GENERALCTRL ASSIGNING <BUMP_S_GENERALCTRL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BUMP_S_GENERALCTRL>-PROCESS_UI = 1.
<BUMP_S_GENERALCTRL>-REVAL_PERCENTAGE = 1.
<BUMP_S_GENERALCTRL>-ROUNDING_MODE = 1.
<BUMP_S_GENERALCTRL>-ROUNDING_FACTOR_UI = 1.
<BUMP_S_GENERALCTRL>-ROUNDING_FACTOR = 1.
ENDLOOP.

LOOP AT IT_BUMP_S_GENERALCTRL INTO WA_BUMP_S_GENERALCTRL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BUMP_S_GENERALCTRL-BUDCAT, sy-vline,
WA_BUMP_S_GENERALCTRL-T_RIB_BUDCAT, sy-vline,
WA_BUMP_S_GENERALCTRL-UPDATEMODE, sy-vline,
WA_BUMP_S_GENERALCTRL-FLG_TEST, sy-vline,
WA_BUMP_S_GENERALCTRL-FLG_DETAILLIST, sy-vline,
WA_BUMP_S_GENERALCTRL-KF_CODE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BUMP_S_GENERALCTRL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BUMP_S_GENERALCTRL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BUMP_S_GENERALCTRL INTO WA_BUMP_S_GENERALCTRL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BUDCAT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BUMP_S_GENERALCTRL-BUDCAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BUMP_S_GENERALCTRL-BUDCAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BUMP_S_GENERALCTRL_STR,
PROCESS_UI TYPE STRING,
REVAL_PERCENTAGE TYPE STRING,
ROUNDING_MODE TYPE STRING,
ROUNDING_FACTOR_UI TYPE STRING,
ROUNDING_FACTOR TYPE STRING,
BUDCAT TYPE STRING,
T_RIB_BUDCAT TYPE STRING,
UPDATEMODE TYPE STRING,
FLG_TEST TYPE STRING,
FLG_DETAILLIST TYPE STRING,
KF_CODE TYPE STRING,
KF_MINPERIOD TYPE STRING,
KF_MAXPERIOD TYPE STRING,
FLG_AUTOCORRECTION TYPE STRING,
FLG_NEG_BUDGET TYPE STRING,
T_BUDCAT_CEFFYEAR TYPE STRING,
FLG_CE_RIB_BLNC TYPE STRING,
FLG_CE_TRANS_BLNC TYPE STRING,
FLG_TEST_AVC_CHECK TYPE STRING,END OF T_EKKO_STR. DATA: WA_BUMP_S_GENERALCTRL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BUMP_S_GENERALCTRL_STR-PROCESS_UI sy-vline
WA_BUMP_S_GENERALCTRL_STR-REVAL_PERCENTAGE sy-vline
WA_BUMP_S_GENERALCTRL_STR-ROUNDING_MODE sy-vline
WA_BUMP_S_GENERALCTRL_STR-ROUNDING_FACTOR_UI sy-vline
WA_BUMP_S_GENERALCTRL_STR-ROUNDING_FACTOR sy-vline
WA_BUMP_S_GENERALCTRL_STR-BUDCAT sy-vline
WA_BUMP_S_GENERALCTRL_STR-T_RIB_BUDCAT sy-vline
WA_BUMP_S_GENERALCTRL_STR-UPDATEMODE sy-vline
WA_BUMP_S_GENERALCTRL_STR-FLG_TEST sy-vline
WA_BUMP_S_GENERALCTRL_STR-FLG_DETAILLIST sy-vline
WA_BUMP_S_GENERALCTRL_STR-KF_CODE sy-vline
WA_BUMP_S_GENERALCTRL_STR-KF_MINPERIOD sy-vline
WA_BUMP_S_GENERALCTRL_STR-KF_MAXPERIOD sy-vline
WA_BUMP_S_GENERALCTRL_STR-FLG_AUTOCORRECTION sy-vline
WA_BUMP_S_GENERALCTRL_STR-FLG_NEG_BUDGET sy-vline
WA_BUMP_S_GENERALCTRL_STR-T_BUDCAT_CEFFYEAR sy-vline
WA_BUMP_S_GENERALCTRL_STR-FLG_CE_RIB_BLNC sy-vline
WA_BUMP_S_GENERALCTRL_STR-FLG_CE_TRANS_BLNC sy-vline
WA_BUMP_S_GENERALCTRL_STR-FLG_TEST_AVC_CHECK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.