ABAP Select data from SAP table BSP_DLCS_DESIGN_ENTRY_ATTR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BSP_DLCS_DESIGN_ENTRY_ATTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BSP_DLCS_DESIGN_ENTRY_ATTR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BSP_DLCS_DESIGN_ENTRY_ATTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BSP_DLCS_DESIGN_ENTRY_ATTR TYPE STANDARD TABLE OF BSP_DLCS_DESIGN_ENTRY_ATTR,
      WA_BSP_DLCS_DESIGN_ENTRY_ATTR TYPE BSP_DLCS_DESIGN_ENTRY_ATTR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BSP_DLCS_DESIGN_ENTRY_ATTR> TYPE BSP_DLCS_DESIGN_ENTRY_ATTR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BSP_DLCS_DESIGN_ENTRY_ATTR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BSP_DLCS_DESIGN_ENTRY_ATTR
  INTO TABLE IT_BSP_DLCS_DESIGN_ENTRY_ATTR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BSP_DLCS_DESIGN_ENTRY_ATTR
*  INTO TABLE @DATA(IT_BSP_DLCS_DESIGN_ENTRY_ATTR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BSP_DLCS_DESIGN_ENTRY_ATTR INDEX 1 INTO DATA(WA_BSP_DLCS_DESIGN_ENTRY_ATTR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BSP_DLCS_DESIGN_ENTRY_ATTR ASSIGNING <BSP_DLCS_DESIGN_ENTRY_ATTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BSP_DLCS_DESIGN_ENTRY_ATTR>-OBJECT_TYPE = 1.
<BSP_DLCS_DESIGN_ENTRY_ATTR>-DSGN_OBJECT = 1.
<BSP_DLCS_DESIGN_ENTRY_ATTR>-ATTR_NAME_BOL = 1.
<BSP_DLCS_DESIGN_ENTRY_ATTR>-HIDDEN = 1.
<BSP_DLCS_DESIGN_ENTRY_ATTR>-MANDATORY = 1.
ENDLOOP.

LOOP AT IT_BSP_DLCS_DESIGN_ENTRY_ATTR INTO WA_BSP_DLCS_DESIGN_ENTRY_ATTR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BSP_DLCS_DESIGN_ENTRY_ATTR-DISABLED, sy-vline,
WA_BSP_DLCS_DESIGN_ENTRY_ATTR-FIELD_LABEL, sy-vline,
WA_BSP_DLCS_DESIGN_ENTRY_ATTR-EXCLUDED, sy-vline,
WA_BSP_DLCS_DESIGN_ENTRY_ATTR-F4_FROM_DDIC, sy-vline,
WA_BSP_DLCS_DESIGN_ENTRY_ATTR-FIELD_TYPE, sy-vline,
WA_BSP_DLCS_DESIGN_ENTRY_ATTR-BOL_ATTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BSP_DLCS_DESIGN_ENTRY_ATTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BSP_DLCS_DESIGN_ENTRY_ATTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BSP_DLCS_DESIGN_ENTRY_ATTR INTO WA_BSP_DLCS_DESIGN_ENTRY_ATTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BSP_DLCS_DESIGN_ENTRY_ATTR_STR,
OBJECT_TYPE TYPE STRING,
DSGN_OBJECT TYPE STRING,
ATTR_NAME_BOL TYPE STRING,
HIDDEN TYPE STRING,
MANDATORY TYPE STRING,
DISABLED TYPE STRING,
FIELD_LABEL TYPE STRING,
EXCLUDED TYPE STRING,
F4_FROM_DDIC TYPE STRING,
FIELD_TYPE TYPE STRING,
BOL_ATTR TYPE STRING,
BOL_OBJECT TYPE STRING,
ACTION TYPE STRING,
PROV_ID TYPE STRING,
RELATION TYPE STRING,
GET_I_METHOD TYPE STRING,
GET_V_METHOD TYPE STRING,
GET_P_METHOD TYPE STRING,
GET_A_METHOD TYPE STRING,
GET_METHOD TYPE STRING,
SET_METHOD TYPE STRING,
IS_GENERIC_OBJECT TYPE STRING,
IS_CUSTOMER_OBJECT TYPE STRING,
IS_STANDARD_OBJECT TYPE STRING,
GET_M_METHOD TYPE STRING,END OF T_EKKO_STR. DATA: WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-OBJECT_TYPE sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-DSGN_OBJECT sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-ATTR_NAME_BOL sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-HIDDEN sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-MANDATORY sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-DISABLED sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-FIELD_LABEL sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-EXCLUDED sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-F4_FROM_DDIC sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-FIELD_TYPE sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-BOL_ATTR sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-BOL_OBJECT sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-ACTION sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-PROV_ID sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-RELATION sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-GET_I_METHOD sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-GET_V_METHOD sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-GET_P_METHOD sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-GET_A_METHOD sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-GET_METHOD sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-SET_METHOD sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-IS_GENERIC_OBJECT sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-IS_CUSTOMER_OBJECT sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-IS_STANDARD_OBJECT sy-vline
WA_BSP_DLCS_DESIGN_ENTRY_ATTR_STR-GET_M_METHOD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.