ABAP Select data from SAP table BSB_ADSSF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BSB_ADSSF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BSB_ADSSF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BSB_ADSSF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BSB_ADSSF TYPE STANDARD TABLE OF BSB_ADSSF,
      WA_BSB_ADSSF TYPE BSB_ADSSF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BSB_ADSSF> TYPE BSB_ADSSF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BSB_ADSSF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BSB_ADSSF
  INTO TABLE IT_BSB_ADSSF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BSB_ADSSF
*  INTO TABLE @DATA(IT_BSB_ADSSF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BSB_ADSSF INDEX 1 INTO DATA(WA_BSB_ADSSF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BSB_ADSSF ASSIGNING <BSB_ADSSF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BSB_ADSSF>-STD_NO = 1.
<BSB_ADSSF>-DUMMY = 1.
<BSB_ADSSF>-STD_RECIP = 1.
<BSB_ADSSF>-HOME_FLAG = 1.
<BSB_ADSSF>-CONSNUMBER = 1.
ENDLOOP.

LOOP AT IT_BSB_ADSSF INTO WA_BSB_ADSSF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BSB_ADSSF-RFCDEST, sy-vline,
WA_BSB_ADSSF-SSFIDSHORT, sy-vline,
WA_BSB_ADSSF-SSF_NS, sy-vline,
WA_BSB_ADSSF-SSF_PROF, sy-vline,
WA_BSB_ADSSF-SSFIDPART1, sy-vline,
WA_BSB_ADSSF-SSFIDPART2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BSB_ADSSF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BSB_ADSSF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BSB_ADSSF INTO WA_BSB_ADSSF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BSB_ADSSF_STR,
STD_NO TYPE STRING,
DUMMY TYPE STRING,
STD_RECIP TYPE STRING,
HOME_FLAG TYPE STRING,
CONSNUMBER TYPE STRING,
RFCDEST TYPE STRING,
SSFIDSHORT TYPE STRING,
SSF_NS TYPE STRING,
SSF_PROF TYPE STRING,
SSFIDPART1 TYPE STRING,
SSFIDPART2 TYPE STRING,
SSFIDPART3 TYPE STRING,
SSFIDPART4 TYPE STRING,
SSFIDPART5 TYPE STRING,
SSFIDPART6 TYPE STRING,
SSFIDPART7 TYPE STRING,
SSFIDPART8 TYPE STRING,
SSFIDPART9 TYPE STRING,
ERRORFLAG TYPE STRING,
FLG_NOUSE TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,END OF T_EKKO_STR. DATA: WA_BSB_ADSSF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BSB_ADSSF_STR-STD_NO sy-vline
WA_BSB_ADSSF_STR-DUMMY sy-vline
WA_BSB_ADSSF_STR-STD_RECIP sy-vline
WA_BSB_ADSSF_STR-HOME_FLAG sy-vline
WA_BSB_ADSSF_STR-CONSNUMBER sy-vline
WA_BSB_ADSSF_STR-RFCDEST sy-vline
WA_BSB_ADSSF_STR-SSFIDSHORT sy-vline
WA_BSB_ADSSF_STR-SSF_NS sy-vline
WA_BSB_ADSSF_STR-SSF_PROF sy-vline
WA_BSB_ADSSF_STR-SSFIDPART1 sy-vline
WA_BSB_ADSSF_STR-SSFIDPART2 sy-vline
WA_BSB_ADSSF_STR-SSFIDPART3 sy-vline
WA_BSB_ADSSF_STR-SSFIDPART4 sy-vline
WA_BSB_ADSSF_STR-SSFIDPART5 sy-vline
WA_BSB_ADSSF_STR-SSFIDPART6 sy-vline
WA_BSB_ADSSF_STR-SSFIDPART7 sy-vline
WA_BSB_ADSSF_STR-SSFIDPART8 sy-vline
WA_BSB_ADSSF_STR-SSFIDPART9 sy-vline
WA_BSB_ADSSF_STR-ERRORFLAG sy-vline
WA_BSB_ADSSF_STR-FLG_NOUSE sy-vline
WA_BSB_ADSSF_STR-VALID_FROM sy-vline
WA_BSB_ADSSF_STR-VALID_TO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.