ABAP Select data from SAP table BORTF_IDT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BORTF_IDT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BORTF_IDT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BORTF_IDT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BORTF_IDT TYPE STANDARD TABLE OF BORTF_IDT,
      WA_BORTF_IDT TYPE BORTF_IDT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BORTF_IDT> TYPE BORTF_IDT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BORTF_IDT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BORTF_IDT
  INTO TABLE IT_BORTF_IDT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BORTF_IDT
*  INTO TABLE @DATA(IT_BORTF_IDT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BORTF_IDT INDEX 1 INTO DATA(WA_BORTF_IDT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BORTF_IDT ASSIGNING <BORTF_IDT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BORTF_IDT>-IDOCNUM = 1.
<BORTF_IDT>-VBELN = 1.
<BORTF_IDT>-ROUTE = 1.
<BORTF_IDT>-LIFNR = 1.
<BORTF_IDT>-STATUS = 1.
ENDLOOP.

LOOP AT IT_BORTF_IDT INTO WA_BORTF_IDT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BORTF_IDT-CUR_EVTLOC, sy-vline,
WA_BORTF_IDT-CUR_EVTQUA, sy-vline,
WA_BORTF_IDT-CUR_EVTTST, sy-vline,
WA_BORTF_IDT-CUR_EVTDAT, sy-vline,
WA_BORTF_IDT-CUR_EVTTIM, sy-vline,
WA_BORTF_IDT-CUR_EVTZON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BORTF_IDT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BORTF_IDT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BORTF_IDT INTO WA_BORTF_IDT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BORTF_IDT-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BORTF_IDT-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BORTF_IDT-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BORTF_IDT-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TKNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BORTF_IDT-TKNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BORTF_IDT-TKNUM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BORTF_IDT_STR,
IDOCNUM TYPE STRING,
VBELN TYPE STRING,
ROUTE TYPE STRING,
LIFNR TYPE STRING,
STATUS TYPE STRING,
CUR_EVTLOC TYPE STRING,
CUR_EVTQUA TYPE STRING,
CUR_EVTTST TYPE STRING,
CUR_EVTDAT TYPE STRING,
CUR_EVTTIM TYPE STRING,
CUR_EVTZON TYPE STRING,
CUR_ESTLOC TYPE STRING,
CUR_ESTQUA TYPE STRING,
CUR_ESTTST TYPE STRING,
CUR_ESTDAT TYPE STRING,
CUR_ESTTIM TYPE STRING,
CUR_ESTZON TYPE STRING,
FIRM_LFDAT TYPE STRING,
INTRNET_R3 TYPE STRING,
TKNUM TYPE STRING,END OF T_EKKO_STR. DATA: WA_BORTF_IDT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BORTF_IDT_STR-IDOCNUM sy-vline
WA_BORTF_IDT_STR-VBELN sy-vline
WA_BORTF_IDT_STR-ROUTE sy-vline
WA_BORTF_IDT_STR-LIFNR sy-vline
WA_BORTF_IDT_STR-STATUS sy-vline
WA_BORTF_IDT_STR-CUR_EVTLOC sy-vline
WA_BORTF_IDT_STR-CUR_EVTQUA sy-vline
WA_BORTF_IDT_STR-CUR_EVTTST sy-vline
WA_BORTF_IDT_STR-CUR_EVTDAT sy-vline
WA_BORTF_IDT_STR-CUR_EVTTIM sy-vline
WA_BORTF_IDT_STR-CUR_EVTZON sy-vline
WA_BORTF_IDT_STR-CUR_ESTLOC sy-vline
WA_BORTF_IDT_STR-CUR_ESTQUA sy-vline
WA_BORTF_IDT_STR-CUR_ESTTST sy-vline
WA_BORTF_IDT_STR-CUR_ESTDAT sy-vline
WA_BORTF_IDT_STR-CUR_ESTTIM sy-vline
WA_BORTF_IDT_STR-CUR_ESTZON sy-vline
WA_BORTF_IDT_STR-FIRM_LFDAT sy-vline
WA_BORTF_IDT_STR-INTRNET_R3 sy-vline
WA_BORTF_IDT_STR-TKNUM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.