ABAP Select data from SAP table BOE_S_REF_DOC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BOE_S_REF_DOC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BOE_S_REF_DOC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BOE_S_REF_DOC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BOE_S_REF_DOC TYPE STANDARD TABLE OF BOE_S_REF_DOC,
      WA_BOE_S_REF_DOC TYPE BOE_S_REF_DOC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BOE_S_REF_DOC> TYPE BOE_S_REF_DOC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BOE_S_REF_DOC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BOE_S_REF_DOC
  INTO TABLE IT_BOE_S_REF_DOC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BOE_S_REF_DOC
*  INTO TABLE @DATA(IT_BOE_S_REF_DOC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BOE_S_REF_DOC INDEX 1 INTO DATA(WA_BOE_S_REF_DOC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BOE_S_REF_DOC ASSIGNING <BOE_S_REF_DOC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BOE_S_REF_DOC>-BOE_NUMBER = 1.
<BOE_S_REF_DOC>-ACTION_KEY = 1.
<BOE_S_REF_DOC>-INVALID_FLAG = 1.
<BOE_S_REF_DOC>-DOC_TYPE = 1.
<BOE_S_REF_DOC>-CREATED_BY = 1.
ENDLOOP.

LOOP AT IT_BOE_S_REF_DOC INTO WA_BOE_S_REF_DOC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BOE_S_REF_DOC-CREATED_AT, sy-vline,
WA_BOE_S_REF_DOC-CHANGED_BY, sy-vline,
WA_BOE_S_REF_DOC-CHANGED_AT, sy-vline,
WA_BOE_S_REF_DOC-VERIDOC_NO, sy-vline,
WA_BOE_S_REF_DOC-BUKRS, sy-vline,
WA_BOE_S_REF_DOC-BELNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BOE_S_REF_DOC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BOE_S_REF_DOC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BOE_S_REF_DOC INTO WA_BOE_S_REF_DOC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field WRBTR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-WRBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-WRBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REBZG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-REBZG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-REBZG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field REBZJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-REBZJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-REBZJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field ORIGINAL_AMOUNT CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-ORIGINAL_AMOUNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-ORIGINAL_AMOUNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field AMOUNT_WITH_SIGN CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-AMOUNT_WITH_SIGN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-AMOUNT_WITH_SIGN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field BOE_PARTIAL_AMT CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-BOE_PARTIAL_AMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-BOE_PARTIAL_AMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field BOE_EPIC_CLM_AMT CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-BOE_EPIC_CLM_AMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-BOE_EPIC_CLM_AMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field BOE_REMAIN_AMT CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-BOE_REMAIN_AMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-BOE_REMAIN_AMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_REF_DOC-HKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_REF_DOC-HKONT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BOE_S_REF_DOC_STR,
BOE_NUMBER TYPE STRING,
ACTION_KEY TYPE STRING,
INVALID_FLAG TYPE STRING,
DOC_TYPE TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_AT TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_AT TYPE STRING,
VERIDOC_NO TYPE STRING,
BUKRS TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BUDAT TYPE STRING,
WRBTR TYPE STRING,
WAERS TYPE STRING,
BLART TYPE STRING,
GSBER TYPE STRING,
PRCTR TYPE STRING,
MONAT TYPE STRING,
BUZEI TYPE STRING,
SHKZG TYPE STRING,
KUNNR TYPE STRING,
LIFNR TYPE STRING,
UMSKZ TYPE STRING,
ZFBDT TYPE STRING,
REBZG TYPE STRING,
REBZJ TYPE STRING,
REBZZ TYPE STRING,
PARTIAL_FLAG TYPE STRING,
ORIGINAL_AMOUNT TYPE STRING,
AMOUNT_WITH_SIGN TYPE STRING,
BOE_PARTIAL_AMT TYPE STRING,
BOE_EPIC_CLM_AMT TYPE STRING,
BOE_REMAIN_AMT TYPE STRING,
BOE_DB_KEY TYPE STRING,
DB_KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
HKONT TYPE STRING,END OF T_EKKO_STR. DATA: WA_BOE_S_REF_DOC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BOE_S_REF_DOC_STR-BOE_NUMBER sy-vline
WA_BOE_S_REF_DOC_STR-ACTION_KEY sy-vline
WA_BOE_S_REF_DOC_STR-INVALID_FLAG sy-vline
WA_BOE_S_REF_DOC_STR-DOC_TYPE sy-vline
WA_BOE_S_REF_DOC_STR-CREATED_BY sy-vline
WA_BOE_S_REF_DOC_STR-CREATED_AT sy-vline
WA_BOE_S_REF_DOC_STR-CHANGED_BY sy-vline
WA_BOE_S_REF_DOC_STR-CHANGED_AT sy-vline
WA_BOE_S_REF_DOC_STR-VERIDOC_NO sy-vline
WA_BOE_S_REF_DOC_STR-BUKRS sy-vline
WA_BOE_S_REF_DOC_STR-BELNR sy-vline
WA_BOE_S_REF_DOC_STR-GJAHR sy-vline
WA_BOE_S_REF_DOC_STR-BUDAT sy-vline
WA_BOE_S_REF_DOC_STR-WRBTR sy-vline
WA_BOE_S_REF_DOC_STR-WAERS sy-vline
WA_BOE_S_REF_DOC_STR-BLART sy-vline
WA_BOE_S_REF_DOC_STR-GSBER sy-vline
WA_BOE_S_REF_DOC_STR-PRCTR sy-vline
WA_BOE_S_REF_DOC_STR-MONAT sy-vline
WA_BOE_S_REF_DOC_STR-BUZEI sy-vline
WA_BOE_S_REF_DOC_STR-SHKZG sy-vline
WA_BOE_S_REF_DOC_STR-KUNNR sy-vline
WA_BOE_S_REF_DOC_STR-LIFNR sy-vline
WA_BOE_S_REF_DOC_STR-UMSKZ sy-vline
WA_BOE_S_REF_DOC_STR-ZFBDT sy-vline
WA_BOE_S_REF_DOC_STR-REBZG sy-vline
WA_BOE_S_REF_DOC_STR-REBZJ sy-vline
WA_BOE_S_REF_DOC_STR-REBZZ sy-vline
WA_BOE_S_REF_DOC_STR-PARTIAL_FLAG sy-vline
WA_BOE_S_REF_DOC_STR-ORIGINAL_AMOUNT sy-vline
WA_BOE_S_REF_DOC_STR-AMOUNT_WITH_SIGN sy-vline
WA_BOE_S_REF_DOC_STR-BOE_PARTIAL_AMT sy-vline
WA_BOE_S_REF_DOC_STR-BOE_EPIC_CLM_AMT sy-vline
WA_BOE_S_REF_DOC_STR-BOE_REMAIN_AMT sy-vline
WA_BOE_S_REF_DOC_STR-BOE_DB_KEY sy-vline
WA_BOE_S_REF_DOC_STR-DB_KEY sy-vline
WA_BOE_S_REF_DOC_STR-PARENT_KEY sy-vline
WA_BOE_S_REF_DOC_STR-ROOT_KEY sy-vline
WA_BOE_S_REF_DOC_STR-HKONT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.