ABAP Select data from SAP table BOE_S_MASS_TRANSACTION into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BOE_S_MASS_TRANSACTION table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BOE_S_MASS_TRANSACTION. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BOE_S_MASS_TRANSACTION table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BOE_S_MASS_TRANSACTION TYPE STANDARD TABLE OF BOE_S_MASS_TRANSACTION,
      WA_BOE_S_MASS_TRANSACTION TYPE BOE_S_MASS_TRANSACTION,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BOE_S_MASS_TRANSACTION> TYPE BOE_S_MASS_TRANSACTION.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BOE_S_MASS_TRANSACTION.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BOE_S_MASS_TRANSACTION
  INTO TABLE IT_BOE_S_MASS_TRANSACTION.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BOE_S_MASS_TRANSACTION
*  INTO TABLE @DATA(IT_BOE_S_MASS_TRANSACTION2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BOE_S_MASS_TRANSACTION INDEX 1 INTO DATA(WA_BOE_S_MASS_TRANSACTION2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BOE_S_MASS_TRANSACTION ASSIGNING <BOE_S_MASS_TRANSACTION>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BOE_S_MASS_TRANSACTION>-BATCH_ID = 1.
<BOE_S_MASS_TRANSACTION>-BOE_INC_ROOT_D = 1.
<BOE_S_MASS_TRANSACTION>-BUKRS = 1.
<BOE_S_MASS_TRANSACTION>-BOE_INTERNAL_NUM = 1.
<BOE_S_MASS_TRANSACTION>-BOE_BLANK_NOTES_VOL_KEY = 1.
ENDLOOP.

LOOP AT IT_BOE_S_MASS_TRANSACTION INTO WA_BOE_S_MASS_TRANSACTION.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BOE_S_MASS_TRANSACTION-BOE_NUMBER, sy-vline,
WA_BOE_S_MASS_TRANSACTION-BOE_TYPE, sy-vline,
WA_BOE_S_MASS_TRANSACTION-BOE_KIND, sy-vline,
WA_BOE_S_MASS_TRANSACTION-BOE_CATEGORY, sy-vline,
WA_BOE_S_MASS_TRANSACTION-BOE_ELECTRONIC, sy-vline,
WA_BOE_S_MASS_TRANSACTION-BOE_PROCESS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BOE_S_MASS_TRANSACTION you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BOE_S_MASS_TRANSACTION TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BOE_S_MASS_TRANSACTION INTO WA_BOE_S_MASS_TRANSACTION. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit AU132, internal->external for field BOE_DEPOSIT_AMOUNT CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_BOE_S_MASS_TRANSACTION-BOE_DEPOSIT_AMOUNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MASS_TRANSACTION-BOE_DEPOSIT_AMOUNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BOE_CONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_MASS_TRANSACTION-BOE_CONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MASS_TRANSACTION-BOE_CONTRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BOE_CONTRACT_AP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_MASS_TRANSACTION-BOE_CONTRACT_AP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MASS_TRANSACTION-BOE_CONTRACT_AP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field WRBTR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_BOE_S_MASS_TRANSACTION-WRBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MASS_TRANSACTION-WRBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_MASS_TRANSACTION-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MASS_TRANSACTION-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_MASS_TRANSACTION-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MASS_TRANSACTION-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_MASS_TRANSACTION-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_MASS_TRANSACTION-PRCTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BOE_S_MASS_TRANSACTION_STR,
BATCH_ID TYPE STRING,
BOE_INC_ROOT_D TYPE STRING,
BUKRS TYPE STRING,
BOE_INTERNAL_NUM TYPE STRING,
BOE_BLANK_NOTES_VOL_KEY TYPE STRING,
BOE_NUMBER TYPE STRING,
BOE_TYPE TYPE STRING,
BOE_KIND TYPE STRING,
BOE_CATEGORY TYPE STRING,
BOE_ELECTRONIC TYPE STRING,
BOE_PROCESS TYPE STRING,
BOE_PROCESS_FLAG TYPE STRING,
BOE_STATUS TYPE STRING,
BOE_FI_STATUS TYPE STRING,
BOE_OWNER TYPE STRING,
BOE_TRANSACTOR TYPE STRING,
BOE_SUBMITTER_NAME TYPE STRING,
BOE_RECEIVE_DATE TYPE STRING,
WDATE TYPE STRING,
WNAME TYPE STRING,
BOE_DRAWER_BANK_NUMBER TYPE STRING,
BOE_DRAWER_BANK_COUNTRY TYPE STRING,
BOE_DRAWER_BANK_ID TYPE STRING,
BOE_DRAWER_BANK TYPE STRING,
BOE_DRAWER_ACCOUNT TYPE STRING,
BOE_CREDIT_RATING TYPE STRING,
BOE_RATING_ORG TYPE STRING,
BOE_RATING_VALID_DATE TYPE STRING,
WBZOG TYPE STRING,
BOE_DRAWEE_ACCOUNT TYPE STRING,
BOE_DRAWEE_BANK_NUMBER TYPE STRING,
BOE_DRAWEE_BANK_COUNTRY TYPE STRING,
BOE_DRAWEE_BANK TYPE STRING,
BOE_COMMENT TYPE STRING,
WBANK TYPE STRING,
BOE_ACC_BANK TYPE STRING,
BOE_ACC_NAME TYPE STRING,
BOE_ACC_BANK_NUMBER TYPE STRING,
BOE_ACC_BANK_COUNTRY TYPE STRING,
BOE_DEPOSIT_ACCOUNT TYPE STRING,
BOE_DEPOSIT_AMOUNT TYPE STRING,
BOE_ENDORSE_FLAG TYPE STRING,
BOE_ENDORSE_NUMBER TYPE STRING,
BOE_ENDOSE TYPE STRING,
BOE_ACC_NUMBER TYPE STRING,
BOE_CONTRACT TYPE STRING,
BOE_CONTRACT_AP TYPE STRING,
ZFBDT TYPE STRING,
WRBTR TYPE STRING,
WAERS TYPE STRING,
KUNNR TYPE STRING,
LIFNR TYPE STRING,
PRCTR TYPE STRING,
GSBER TYPE STRING,
BOE_TRANSACTION TYPE STRING,
BOE_PLANNING_DATE TYPE STRING,
UNIT_ID TYPE STRING,
STEXT TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_AT TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_AT TYPE STRING,
BOE_NEGOT TYPE STRING,
BOE_OVERDUE TYPE STRING,
BOE_VERIFIED TYPE STRING,
BOE_PLE_POOL TYPE STRING,
PLEDGE_BOENO TYPE STRING,
BOE_CROSS_SRC_TRANS_ID TYPE STRING,
BOE_CROSS_TGT_TRANS_ID TYPE STRING,
BOE_CURR_TRANS_ID TYPE STRING,
BOE_CURR_TRANS_NUM TYPE STRING,
BOE_CURR_TRANS_TYPE TYPE STRING,
BOE_BLOCK TYPE STRING,
BOE_BLOCK_REASON TYPE STRING,
VOID_REASON TYPE STRING,
BOE_REJECT_FLAG TYPE STRING,
BANK_SERIAL_NO TYPE STRING,
BANK_RECALL_SERIAL_NO TYPE STRING,
EBR_ID TYPE STRING,
HBKID TYPE STRING,
HKTID TYPE STRING,END OF T_EKKO_STR. DATA: WA_BOE_S_MASS_TRANSACTION_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BATCH_ID sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_INC_ROOT_D sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BUKRS sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_INTERNAL_NUM sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_BLANK_NOTES_VOL_KEY sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_NUMBER sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_TYPE sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_KIND sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_CATEGORY sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_ELECTRONIC sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_PROCESS sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_PROCESS_FLAG sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_STATUS sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_FI_STATUS sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_OWNER sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_TRANSACTOR sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_SUBMITTER_NAME sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_RECEIVE_DATE sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-WDATE sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-WNAME sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_DRAWER_BANK_NUMBER sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_DRAWER_BANK_COUNTRY sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_DRAWER_BANK_ID sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_DRAWER_BANK sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_DRAWER_ACCOUNT sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_CREDIT_RATING sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_RATING_ORG sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_RATING_VALID_DATE sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-WBZOG sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_DRAWEE_ACCOUNT sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_DRAWEE_BANK_NUMBER sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_DRAWEE_BANK_COUNTRY sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_DRAWEE_BANK sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_COMMENT sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-WBANK sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_ACC_BANK sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_ACC_NAME sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_ACC_BANK_NUMBER sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_ACC_BANK_COUNTRY sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_DEPOSIT_ACCOUNT sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_DEPOSIT_AMOUNT sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_ENDORSE_FLAG sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_ENDORSE_NUMBER sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_ENDOSE sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_ACC_NUMBER sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_CONTRACT sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_CONTRACT_AP sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-ZFBDT sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-WRBTR sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-WAERS sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-KUNNR sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-LIFNR sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-PRCTR sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-GSBER sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_TRANSACTION sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_PLANNING_DATE sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-UNIT_ID sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-STEXT sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-CREATED_BY sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-CREATED_AT sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-CHANGED_BY sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-CHANGED_AT sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_NEGOT sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_OVERDUE sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_VERIFIED sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_PLE_POOL sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-PLEDGE_BOENO sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_CROSS_SRC_TRANS_ID sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_CROSS_TGT_TRANS_ID sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_CURR_TRANS_ID sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_CURR_TRANS_NUM sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_CURR_TRANS_TYPE sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_BLOCK sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_BLOCK_REASON sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-VOID_REASON sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BOE_REJECT_FLAG sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BANK_SERIAL_NO sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-BANK_RECALL_SERIAL_NO sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-EBR_ID sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-HBKID sy-vline
WA_BOE_S_MASS_TRANSACTION_STR-HKTID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.