ABAP Select data from SAP table BOE_S_FI_INTEGRATION into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BOE_S_FI_INTEGRATION table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BOE_S_FI_INTEGRATION. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BOE_S_FI_INTEGRATION table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BOE_S_FI_INTEGRATION TYPE STANDARD TABLE OF BOE_S_FI_INTEGRATION,
      WA_BOE_S_FI_INTEGRATION TYPE BOE_S_FI_INTEGRATION,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BOE_S_FI_INTEGRATION> TYPE BOE_S_FI_INTEGRATION.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BOE_S_FI_INTEGRATION.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BOE_S_FI_INTEGRATION
  INTO TABLE IT_BOE_S_FI_INTEGRATION.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BOE_S_FI_INTEGRATION
*  INTO TABLE @DATA(IT_BOE_S_FI_INTEGRATION2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BOE_S_FI_INTEGRATION INDEX 1 INTO DATA(WA_BOE_S_FI_INTEGRATION2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BOE_S_FI_INTEGRATION ASSIGNING <BOE_S_FI_INTEGRATION>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BOE_S_FI_INTEGRATION>-BUKRS = 1.
<BOE_S_FI_INTEGRATION>-BELNR = 1.
<BOE_S_FI_INTEGRATION>-GJAHR = 1.
<BOE_S_FI_INTEGRATION>-BUDAT = 1.
<BOE_S_FI_INTEGRATION>-WRBTR = 1.
ENDLOOP.

LOOP AT IT_BOE_S_FI_INTEGRATION INTO WA_BOE_S_FI_INTEGRATION.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BOE_S_FI_INTEGRATION-WAERS, sy-vline,
WA_BOE_S_FI_INTEGRATION-BLART, sy-vline,
WA_BOE_S_FI_INTEGRATION-GSBER, sy-vline,
WA_BOE_S_FI_INTEGRATION-PRCTR, sy-vline,
WA_BOE_S_FI_INTEGRATION-MONAT, sy-vline,
WA_BOE_S_FI_INTEGRATION-BUZEI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BOE_S_FI_INTEGRATION you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BOE_S_FI_INTEGRATION TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BOE_S_FI_INTEGRATION INTO WA_BOE_S_FI_INTEGRATION. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_BOE_S_FI_INTEGRATION-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_FI_INTEGRATION-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field WRBTR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_BOE_S_FI_INTEGRATION-WRBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_FI_INTEGRATION-WRBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_FI_INTEGRATION-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_FI_INTEGRATION-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_FI_INTEGRATION-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_FI_INTEGRATION-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_FI_INTEGRATION-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_FI_INTEGRATION-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REBZG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BOE_S_FI_INTEGRATION-REBZG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_FI_INTEGRATION-REBZG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field REBZJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_BOE_S_FI_INTEGRATION-REBZJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BOE_S_FI_INTEGRATION-REBZJ.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BOE_S_FI_INTEGRATION_STR,
BUKRS TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BUDAT TYPE STRING,
WRBTR TYPE STRING,
WAERS TYPE STRING,
BLART TYPE STRING,
GSBER TYPE STRING,
PRCTR TYPE STRING,
MONAT TYPE STRING,
BUZEI TYPE STRING,
SHKZG TYPE STRING,
KUNNR TYPE STRING,
LIFNR TYPE STRING,
UMSKZ TYPE STRING,
ZFBDT TYPE STRING,
REBZG TYPE STRING,
REBZJ TYPE STRING,
REBZZ TYPE STRING,
BOE_INTERNAL_NUM TYPE STRING,
BOE_VOID_FLAG TYPE STRING,
DOC_TYPE TYPE STRING,
VERIDOC_NO TYPE STRING,
BOE_REVERSE_FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_BOE_S_FI_INTEGRATION_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BOE_S_FI_INTEGRATION_STR-BUKRS sy-vline
WA_BOE_S_FI_INTEGRATION_STR-BELNR sy-vline
WA_BOE_S_FI_INTEGRATION_STR-GJAHR sy-vline
WA_BOE_S_FI_INTEGRATION_STR-BUDAT sy-vline
WA_BOE_S_FI_INTEGRATION_STR-WRBTR sy-vline
WA_BOE_S_FI_INTEGRATION_STR-WAERS sy-vline
WA_BOE_S_FI_INTEGRATION_STR-BLART sy-vline
WA_BOE_S_FI_INTEGRATION_STR-GSBER sy-vline
WA_BOE_S_FI_INTEGRATION_STR-PRCTR sy-vline
WA_BOE_S_FI_INTEGRATION_STR-MONAT sy-vline
WA_BOE_S_FI_INTEGRATION_STR-BUZEI sy-vline
WA_BOE_S_FI_INTEGRATION_STR-SHKZG sy-vline
WA_BOE_S_FI_INTEGRATION_STR-KUNNR sy-vline
WA_BOE_S_FI_INTEGRATION_STR-LIFNR sy-vline
WA_BOE_S_FI_INTEGRATION_STR-UMSKZ sy-vline
WA_BOE_S_FI_INTEGRATION_STR-ZFBDT sy-vline
WA_BOE_S_FI_INTEGRATION_STR-REBZG sy-vline
WA_BOE_S_FI_INTEGRATION_STR-REBZJ sy-vline
WA_BOE_S_FI_INTEGRATION_STR-REBZZ sy-vline
WA_BOE_S_FI_INTEGRATION_STR-BOE_INTERNAL_NUM sy-vline
WA_BOE_S_FI_INTEGRATION_STR-BOE_VOID_FLAG sy-vline
WA_BOE_S_FI_INTEGRATION_STR-DOC_TYPE sy-vline
WA_BOE_S_FI_INTEGRATION_STR-VERIDOC_NO sy-vline
WA_BOE_S_FI_INTEGRATION_STR-BOE_REVERSE_FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.