ABAP Select data from SAP table BIW_PRHI_V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BIW_PRHI_V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BIW_PRHI_V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BIW_PRHI_V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BIW_PRHI_V TYPE STANDARD TABLE OF BIW_PRHI_V,
      WA_BIW_PRHI_V TYPE BIW_PRHI_V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BIW_PRHI_V> TYPE BIW_PRHI_V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BIW_PRHI_V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BIW_PRHI_V
  INTO TABLE IT_BIW_PRHI_V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BIW_PRHI_V
*  INTO TABLE @DATA(IT_BIW_PRHI_V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BIW_PRHI_V INDEX 1 INTO DATA(WA_BIW_PRHI_V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BIW_PRHI_V ASSIGNING <BIW_PRHI_V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BIW_PRHI_V>-MANDT = 1.
<BIW_PRHI_V>-PSPNR = 1.
<BIW_PRHI_V>-UP = 1.
<BIW_PRHI_V>-DOWN = 1.
<BIW_PRHI_V>-LEFT = 1.
ENDLOOP.

LOOP AT IT_BIW_PRHI_V INTO WA_BIW_PRHI_V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BIW_PRHI_V-RIGHT, sy-vline,
WA_BIW_PRHI_V-STUFE, sy-vline,
WA_BIW_PRHI_V-PSPHI, sy-vline,
WA_BIW_PRHI_V-POSID, sy-vline,
ENDLOOP. *Add any further fields from structure WA_BIW_PRHI_V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BIW_PRHI_V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BIW_PRHI_V INTO WA_BIW_PRHI_V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ABPSP, internal->external for field PSPNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_BIW_PRHI_V-PSPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_PRHI_V-PSPNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field UP CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_BIW_PRHI_V-UP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_PRHI_V-UP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field DOWN CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_BIW_PRHI_V-DOWN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_PRHI_V-DOWN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field LEFT CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_BIW_PRHI_V-LEFT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_PRHI_V-LEFT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field RIGHT CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_BIW_PRHI_V-RIGHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_PRHI_V-RIGHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit KONPD, internal->external for field PSPHI CALL FUNCTION 'CONVERSION_EXIT_KONPD_OUTPUT' EXPORTING input = WA_BIW_PRHI_V-PSPHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_PRHI_V-PSPHI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field POSID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_BIW_PRHI_V-POSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_PRHI_V-POSID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BIW_PRHI_V_STR,
MANDT TYPE STRING,
PSPNR TYPE STRING,
UP TYPE STRING,
DOWN TYPE STRING,
LEFT TYPE STRING,
RIGHT TYPE STRING,
STUFE TYPE STRING,
PSPHI TYPE STRING,
POSID TYPE STRING,END OF T_EKKO_STR. DATA: WA_BIW_PRHI_V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BIW_PRHI_V_STR-MANDT sy-vline
WA_BIW_PRHI_V_STR-PSPNR sy-vline
WA_BIW_PRHI_V_STR-UP sy-vline
WA_BIW_PRHI_V_STR-DOWN sy-vline
WA_BIW_PRHI_V_STR-LEFT sy-vline
WA_BIW_PRHI_V_STR-RIGHT sy-vline
WA_BIW_PRHI_V_STR-STUFE sy-vline
WA_BIW_PRHI_V_STR-PSPHI sy-vline
WA_BIW_PRHI_V_STR-POSID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.