ABAP Select data from SAP table BIW_NAE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BIW_NAE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BIW_NAE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BIW_NAE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BIW_NAE TYPE STANDARD TABLE OF BIW_NAE,
      WA_BIW_NAE TYPE BIW_NAE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BIW_NAE> TYPE BIW_NAE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BIW_NAE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BIW_NAE
  INTO TABLE IT_BIW_NAE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BIW_NAE
*  INTO TABLE @DATA(IT_BIW_NAE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BIW_NAE INDEX 1 INTO DATA(WA_BIW_NAE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BIW_NAE ASSIGNING <BIW_NAE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BIW_NAE>-MANDT = 1.
<BIW_NAE>-AUFNR = 1.
<BIW_NAE>-VORNR = 1.
<BIW_NAE>-APLZL = 1.
<BIW_NAE>-AUFPL = 1.
ENDLOOP.

LOOP AT IT_BIW_NAE INTO WA_BIW_NAE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BIW_NAE-PSPID_NP_I, sy-vline,
WA_BIW_NAE-POSID_NP_I, sy-vline,
WA_BIW_NAE-POSID_NV_I, sy-vline,
WA_BIW_NAE-ERDAT, sy-vline,
WA_BIW_NAE-AEDAT, sy-vline,
WA_BIW_NAE-KOKRS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BIW_NAE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BIW_NAE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BIW_NAE INTO WA_BIW_NAE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_NAE-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_BIW_NAE-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit KONPD, internal->external for field PSPID_NP_I CALL FUNCTION 'CONVERSION_EXIT_KONPD_OUTPUT' EXPORTING input = WA_BIW_NAE-PSPID_NP_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-PSPID_NP_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field POSID_NP_I CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_BIW_NAE-POSID_NP_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-POSID_NP_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field POSID_NV_I CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_BIW_NAE-POSID_NV_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-POSID_NV_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANFKO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_NAE-ANFKO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-ANFKO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_NAE-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_NAE-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKTO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_NAE-SAKTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-SAKTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_NAE-INFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-INFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SCOPE, internal->external for field SCOPE CALL FUNCTION 'CONVERSION_EXIT_SCOPE_OUTPUT' EXPORTING input = WA_BIW_NAE-SCOPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-SCOPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_NAE-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_BIW_NAE-USE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-USE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_BIW_NAE-USE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_NAE-USE05.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BIW_NAE_STR,
MANDT TYPE STRING,
AUFNR TYPE STRING,
VORNR TYPE STRING,
APLZL TYPE STRING,
AUFPL TYPE STRING,
PSPID_NP_I TYPE STRING,
POSID_NP_I TYPE STRING,
POSID_NV_I TYPE STRING,
ERDAT TYPE STRING,
AEDAT TYPE STRING,
KOKRS TYPE STRING,
AUTYP TYPE STRING,
DISPO TYPE STRING,
WERKS TYPE STRING,
ANFKO TYPE STRING,
GSBER TYPE STRING,
PRCTR TYPE STRING,
STEUS TYPE STRING,
LIFNR TYPE STRING,
SAKTO TYPE STRING,
WAERS TYPE STRING,
INFNR TYPE STRING,
EKORG TYPE STRING,
EKGRP TYPE STRING,
MATKL TYPE STRING,
BUKRS TYPE STRING,
ANFKOKRS TYPE STRING,
LARNT TYPE STRING,
NPRIO TYPE STRING,
SCOPE TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
ARBID TYPE STRING,
SUMNR TYPE STRING,
OBJNR TYPE STRING,
LTXA1 TYPE STRING,
USR00 TYPE STRING,
USR01 TYPE STRING,
USR02 TYPE STRING,
USR03 TYPE STRING,
USR04 TYPE STRING,
USE04 TYPE STRING,
USR05 TYPE STRING,
USE05 TYPE STRING,
USR06 TYPE STRING,
USE06 TYPE STRING,
USR07 TYPE STRING,
USE07 TYPE STRING,
USR08 TYPE STRING,
USR09 TYPE STRING,
USR10 TYPE STRING,
USR11 TYPE STRING,END OF T_EKKO_STR. DATA: WA_BIW_NAE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BIW_NAE_STR-MANDT sy-vline
WA_BIW_NAE_STR-AUFNR sy-vline
WA_BIW_NAE_STR-VORNR sy-vline
WA_BIW_NAE_STR-APLZL sy-vline
WA_BIW_NAE_STR-AUFPL sy-vline
WA_BIW_NAE_STR-PSPID_NP_I sy-vline
WA_BIW_NAE_STR-POSID_NP_I sy-vline
WA_BIW_NAE_STR-POSID_NV_I sy-vline
WA_BIW_NAE_STR-ERDAT sy-vline
WA_BIW_NAE_STR-AEDAT sy-vline
WA_BIW_NAE_STR-KOKRS sy-vline
WA_BIW_NAE_STR-AUTYP sy-vline
WA_BIW_NAE_STR-DISPO sy-vline
WA_BIW_NAE_STR-WERKS sy-vline
WA_BIW_NAE_STR-ANFKO sy-vline
WA_BIW_NAE_STR-GSBER sy-vline
WA_BIW_NAE_STR-PRCTR sy-vline
WA_BIW_NAE_STR-STEUS sy-vline
WA_BIW_NAE_STR-LIFNR sy-vline
WA_BIW_NAE_STR-SAKTO sy-vline
WA_BIW_NAE_STR-WAERS sy-vline
WA_BIW_NAE_STR-INFNR sy-vline
WA_BIW_NAE_STR-EKORG sy-vline
WA_BIW_NAE_STR-EKGRP sy-vline
WA_BIW_NAE_STR-MATKL sy-vline
WA_BIW_NAE_STR-BUKRS sy-vline
WA_BIW_NAE_STR-ANFKOKRS sy-vline
WA_BIW_NAE_STR-LARNT sy-vline
WA_BIW_NAE_STR-NPRIO sy-vline
WA_BIW_NAE_STR-SCOPE sy-vline
WA_BIW_NAE_STR-EBELN sy-vline
WA_BIW_NAE_STR-EBELP sy-vline
WA_BIW_NAE_STR-ARBID sy-vline
WA_BIW_NAE_STR-SUMNR sy-vline
WA_BIW_NAE_STR-OBJNR sy-vline
WA_BIW_NAE_STR-LTXA1 sy-vline
WA_BIW_NAE_STR-USR00 sy-vline
WA_BIW_NAE_STR-USR01 sy-vline
WA_BIW_NAE_STR-USR02 sy-vline
WA_BIW_NAE_STR-USR03 sy-vline
WA_BIW_NAE_STR-USR04 sy-vline
WA_BIW_NAE_STR-USE04 sy-vline
WA_BIW_NAE_STR-USR05 sy-vline
WA_BIW_NAE_STR-USE05 sy-vline
WA_BIW_NAE_STR-USR06 sy-vline
WA_BIW_NAE_STR-USE06 sy-vline
WA_BIW_NAE_STR-USR07 sy-vline
WA_BIW_NAE_STR-USE07 sy-vline
WA_BIW_NAE_STR-USR08 sy-vline
WA_BIW_NAE_STR-USR09 sy-vline
WA_BIW_NAE_STR-USR10 sy-vline
WA_BIW_NAE_STR-USR11 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.