ABAP Select data from SAP table BIW_ISU_DEVCAT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BIW_ISU_DEVCAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BIW_ISU_DEVCAT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BIW_ISU_DEVCAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BIW_ISU_DEVCAT TYPE STANDARD TABLE OF BIW_ISU_DEVCAT,
      WA_BIW_ISU_DEVCAT TYPE BIW_ISU_DEVCAT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BIW_ISU_DEVCAT> TYPE BIW_ISU_DEVCAT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BIW_ISU_DEVCAT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BIW_ISU_DEVCAT
  INTO TABLE IT_BIW_ISU_DEVCAT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BIW_ISU_DEVCAT
*  INTO TABLE @DATA(IT_BIW_ISU_DEVCAT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BIW_ISU_DEVCAT INDEX 1 INTO DATA(WA_BIW_ISU_DEVCAT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BIW_ISU_DEVCAT ASSIGNING <BIW_ISU_DEVCAT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BIW_ISU_DEVCAT>-MANDT = 1.
<BIW_ISU_DEVCAT>-MATNR = 1.
<BIW_ISU_DEVCAT>-KOMBINAT = 1.
<BIW_ISU_DEVCAT>-FUNKLAS = 1.
<BIW_ISU_DEVCAT>-BAUKLAS = 1.
ENDLOOP.

LOOP AT IT_BIW_ISU_DEVCAT INTO WA_BIW_ISU_DEVCAT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BIW_ISU_DEVCAT-BAUFORM, sy-vline,
WA_BIW_ISU_DEVCAT-BAUTXT, sy-vline,
WA_BIW_ISU_DEVCAT-PREISKLA, sy-vline,
WA_BIW_ISU_DEVCAT-PTBNUM, sy-vline,
WA_BIW_ISU_DEVCAT-DVGWNUM, sy-vline,
WA_BIW_ISU_DEVCAT-BGLKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BIW_ISU_DEVCAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BIW_ISU_DEVCAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BIW_ISU_DEVCAT INTO WA_BIW_ISU_DEVCAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PREISKLA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-PREISKLA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-PREISKLA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ZWGRUPPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-ZWGRUPPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-ZWGRUPPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EAGRUPPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-EAGRUPPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-EAGRUPPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WGRUPPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-WGRUPPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-WGRUPPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field GRPMATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-GRPMATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-GRPMATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ABMEIH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-ABMEIH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-ABMEIH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LADZ_EIH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-LADZ_EIH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-LADZ_EIH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LADV_EIH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-LADV_EIH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-LADV_EIH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEIH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-GEWEIH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-GEWEIH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWLEER_EIH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-GEWLEER_EIH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-GEWLEER_EIH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit RAT11, internal->external for field RATING CALL FUNCTION 'CONVERSION_EXIT_RAT11_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-RATING IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-RATING.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PVOLT, internal->external for field P_VOLTAGE CALL FUNCTION 'CONVERSION_EXIT_PVOLT_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-P_VOLTAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-P_VOLTAGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SVOLT, internal->external for field S_VOLTAGE CALL FUNCTION 'CONVERSION_EXIT_SVOLT_OUTPUT' EXPORTING input = WA_BIW_ISU_DEVCAT-S_VOLTAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_ISU_DEVCAT-S_VOLTAGE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BIW_ISU_DEVCAT_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
KOMBINAT TYPE STRING,
FUNKLAS TYPE STRING,
BAUKLAS TYPE STRING,
BAUFORM TYPE STRING,
BAUTXT TYPE STRING,
PREISKLA TYPE STRING,
PTBNUM TYPE STRING,
DVGWNUM TYPE STRING,
BGLKZ TYPE STRING,
VLZEITT TYPE STRING,
VLZEITTI TYPE STRING,
VLZEITN TYPE STRING,
VLKZBAU TYPE STRING,
ZWGRUPPE TYPE STRING,
EAGRUPPE TYPE STRING,
MESSART TYPE STRING,
UEBERVER TYPE STRING,
BGLNETZ TYPE STRING,
WGRUPPE TYPE STRING,
PRIMWNR1 TYPE STRING,
SEKWNR1 TYPE STRING,
PRIMWNR2 TYPE STRING,
SEKWNR2 TYPE STRING,
AENAM TYPE STRING,
AEDAT TYPE STRING,
ZSPANNS TYPE STRING,
ZSTROMS TYPE STRING,
ZSPANNP TYPE STRING,
ZSTROMP TYPE STRING,
GRPMATNR TYPE STRING,
ORDER_CODE TYPE STRING,
SPARTE TYPE STRING,
NENNBEL TYPE STRING,
KENNZTYP TYPE STRING,
KENNZTYP_TXT TYPE STRING,
STELLPLATZ TYPE STRING,
HOEHEBEH TYPE STRING,
BREITEBEH TYPE STRING,
TIEFEBEH TYPE STRING,
ABMEIH TYPE STRING,
LADEZEIT TYPE STRING,
LADZ_EIH TYPE STRING,
LADEVOL TYPE STRING,
LADV_EIH TYPE STRING,
GEW_ZUL TYPE STRING,
GEWEIH TYPE STRING,
EIGENTUM TYPE STRING,
EIGENTUM_TXT TYPE STRING,
LADV_TXT TYPE STRING,
LADZ_TXT TYPE STRING,
GEW_TXT TYPE STRING,
ABM_TXT TYPE STRING,
PRODUCT_AREA TYPE STRING,
GEW_LEER TYPE STRING,
GEWLEER_EIH TYPE STRING,
GEWLEER_TXT TYPE STRING,
NOTIF_CODE TYPE STRING,
G_INFOSATZ TYPE STRING,
PPM_METER TYPE STRING,
LOSSDTGROUP TYPE STRING,
RATING TYPE STRING,
P_VOLTAGE TYPE STRING,
S_VOLTAGE TYPE STRING,
AMS_DGRP TYPE STRING,
AMCG_DGRP TYPE STRING,
SMART_METER TYPE STRING,
MSG_DGRP_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_BIW_ISU_DEVCAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BIW_ISU_DEVCAT_STR-MANDT sy-vline
WA_BIW_ISU_DEVCAT_STR-MATNR sy-vline
WA_BIW_ISU_DEVCAT_STR-KOMBINAT sy-vline
WA_BIW_ISU_DEVCAT_STR-FUNKLAS sy-vline
WA_BIW_ISU_DEVCAT_STR-BAUKLAS sy-vline
WA_BIW_ISU_DEVCAT_STR-BAUFORM sy-vline
WA_BIW_ISU_DEVCAT_STR-BAUTXT sy-vline
WA_BIW_ISU_DEVCAT_STR-PREISKLA sy-vline
WA_BIW_ISU_DEVCAT_STR-PTBNUM sy-vline
WA_BIW_ISU_DEVCAT_STR-DVGWNUM sy-vline
WA_BIW_ISU_DEVCAT_STR-BGLKZ sy-vline
WA_BIW_ISU_DEVCAT_STR-VLZEITT sy-vline
WA_BIW_ISU_DEVCAT_STR-VLZEITTI sy-vline
WA_BIW_ISU_DEVCAT_STR-VLZEITN sy-vline
WA_BIW_ISU_DEVCAT_STR-VLKZBAU sy-vline
WA_BIW_ISU_DEVCAT_STR-ZWGRUPPE sy-vline
WA_BIW_ISU_DEVCAT_STR-EAGRUPPE sy-vline
WA_BIW_ISU_DEVCAT_STR-MESSART sy-vline
WA_BIW_ISU_DEVCAT_STR-UEBERVER sy-vline
WA_BIW_ISU_DEVCAT_STR-BGLNETZ sy-vline
WA_BIW_ISU_DEVCAT_STR-WGRUPPE sy-vline
WA_BIW_ISU_DEVCAT_STR-PRIMWNR1 sy-vline
WA_BIW_ISU_DEVCAT_STR-SEKWNR1 sy-vline
WA_BIW_ISU_DEVCAT_STR-PRIMWNR2 sy-vline
WA_BIW_ISU_DEVCAT_STR-SEKWNR2 sy-vline
WA_BIW_ISU_DEVCAT_STR-AENAM sy-vline
WA_BIW_ISU_DEVCAT_STR-AEDAT sy-vline
WA_BIW_ISU_DEVCAT_STR-ZSPANNS sy-vline
WA_BIW_ISU_DEVCAT_STR-ZSTROMS sy-vline
WA_BIW_ISU_DEVCAT_STR-ZSPANNP sy-vline
WA_BIW_ISU_DEVCAT_STR-ZSTROMP sy-vline
WA_BIW_ISU_DEVCAT_STR-GRPMATNR sy-vline
WA_BIW_ISU_DEVCAT_STR-ORDER_CODE sy-vline
WA_BIW_ISU_DEVCAT_STR-SPARTE sy-vline
WA_BIW_ISU_DEVCAT_STR-NENNBEL sy-vline
WA_BIW_ISU_DEVCAT_STR-KENNZTYP sy-vline
WA_BIW_ISU_DEVCAT_STR-KENNZTYP_TXT sy-vline
WA_BIW_ISU_DEVCAT_STR-STELLPLATZ sy-vline
WA_BIW_ISU_DEVCAT_STR-HOEHEBEH sy-vline
WA_BIW_ISU_DEVCAT_STR-BREITEBEH sy-vline
WA_BIW_ISU_DEVCAT_STR-TIEFEBEH sy-vline
WA_BIW_ISU_DEVCAT_STR-ABMEIH sy-vline
WA_BIW_ISU_DEVCAT_STR-LADEZEIT sy-vline
WA_BIW_ISU_DEVCAT_STR-LADZ_EIH sy-vline
WA_BIW_ISU_DEVCAT_STR-LADEVOL sy-vline
WA_BIW_ISU_DEVCAT_STR-LADV_EIH sy-vline
WA_BIW_ISU_DEVCAT_STR-GEW_ZUL sy-vline
WA_BIW_ISU_DEVCAT_STR-GEWEIH sy-vline
WA_BIW_ISU_DEVCAT_STR-EIGENTUM sy-vline
WA_BIW_ISU_DEVCAT_STR-EIGENTUM_TXT sy-vline
WA_BIW_ISU_DEVCAT_STR-LADV_TXT sy-vline
WA_BIW_ISU_DEVCAT_STR-LADZ_TXT sy-vline
WA_BIW_ISU_DEVCAT_STR-GEW_TXT sy-vline
WA_BIW_ISU_DEVCAT_STR-ABM_TXT sy-vline
WA_BIW_ISU_DEVCAT_STR-PRODUCT_AREA sy-vline
WA_BIW_ISU_DEVCAT_STR-GEW_LEER sy-vline
WA_BIW_ISU_DEVCAT_STR-GEWLEER_EIH sy-vline
WA_BIW_ISU_DEVCAT_STR-GEWLEER_TXT sy-vline
WA_BIW_ISU_DEVCAT_STR-NOTIF_CODE sy-vline
WA_BIW_ISU_DEVCAT_STR-G_INFOSATZ sy-vline
WA_BIW_ISU_DEVCAT_STR-PPM_METER sy-vline
WA_BIW_ISU_DEVCAT_STR-LOSSDTGROUP sy-vline
WA_BIW_ISU_DEVCAT_STR-RATING sy-vline
WA_BIW_ISU_DEVCAT_STR-P_VOLTAGE sy-vline
WA_BIW_ISU_DEVCAT_STR-S_VOLTAGE sy-vline
WA_BIW_ISU_DEVCAT_STR-AMS_DGRP sy-vline
WA_BIW_ISU_DEVCAT_STR-AMCG_DGRP sy-vline
WA_BIW_ISU_DEVCAT_STR-SMART_METER sy-vline
WA_BIW_ISU_DEVCAT_STR-MSG_DGRP_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.