ABAP Select data from SAP table BIW_CEPC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BIW_CEPC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BIW_CEPC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BIW_CEPC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BIW_CEPC TYPE STANDARD TABLE OF BIW_CEPC,
      WA_BIW_CEPC TYPE BIW_CEPC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BIW_CEPC> TYPE BIW_CEPC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BIW_CEPC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BIW_CEPC
  INTO TABLE IT_BIW_CEPC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BIW_CEPC
*  INTO TABLE @DATA(IT_BIW_CEPC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BIW_CEPC INDEX 1 INTO DATA(WA_BIW_CEPC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BIW_CEPC ASSIGNING <BIW_CEPC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BIW_CEPC>-MANDT = 1.
<BIW_CEPC>-KOKRS = 1.
<BIW_CEPC>-PRCTR = 1.
<BIW_CEPC>-DATETO = 1.
<BIW_CEPC>-DATEFROM = 1.
ENDLOOP.

LOOP AT IT_BIW_CEPC INTO WA_BIW_CEPC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BIW_CEPC-ERSDA, sy-vline,
WA_BIW_CEPC-USNAM, sy-vline,
WA_BIW_CEPC-MERKMAL, sy-vline,
WA_BIW_CEPC-ABTEI, sy-vline,
WA_BIW_CEPC-VERAK, sy-vline,
WA_BIW_CEPC-VERAK_USER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BIW_CEPC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BIW_CEPC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BIW_CEPC INTO WA_BIW_CEPC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_CEPC-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_CEPC-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NPRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_CEPC-NPRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_CEPC-NPRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_BIW_CEPC-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_CEPC-SPRAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_CEPC-VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_CEPC-VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_CEPC-RECID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_CEPC-RECID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ETYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_CEPC-ETYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_CEPC-ETYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_CEPC-LOGSYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_CEPC-LOGSYSTEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEGMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BIW_CEPC-SEGMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BIW_CEPC-SEGMENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BIW_CEPC_STR,
MANDT TYPE STRING,
KOKRS TYPE STRING,
PRCTR TYPE STRING,
DATETO TYPE STRING,
DATEFROM TYPE STRING,
ERSDA TYPE STRING,
USNAM TYPE STRING,
MERKMAL TYPE STRING,
ABTEI TYPE STRING,
VERAK TYPE STRING,
VERAK_USER TYPE STRING,
WAERS TYPE STRING,
NPRCTR TYPE STRING,
LAND1 TYPE STRING,
ANRED TYPE STRING,
NAME1 TYPE STRING,
NAME2 TYPE STRING,
NAME3 TYPE STRING,
NAME4 TYPE STRING,
ORT01 TYPE STRING,
ORT02 TYPE STRING,
STRAS TYPE STRING,
PFACH TYPE STRING,
PSTLZ TYPE STRING,
PSTL2 TYPE STRING,
SPRAS TYPE STRING,
TELBX TYPE STRING,
TELF1 TYPE STRING,
TELF2 TYPE STRING,
TELFX TYPE STRING,
TELTX TYPE STRING,
TELX1 TYPE STRING,
DATLT TYPE STRING,
DRNAM TYPE STRING,
KHINR TYPE STRING,
BUKRS TYPE STRING,
VNAME TYPE STRING,
RECID TYPE STRING,
ETYPE TYPE STRING,
TXJCD TYPE STRING,
REGIO TYPE STRING,
KVEWE TYPE STRING,
KAPPL TYPE STRING,
KALSM TYPE STRING,
LOGSYSTEM TYPE STRING,
LOCK_IND TYPE STRING,
PCA_TEMPLATE TYPE STRING,
SEGMENT TYPE STRING,
EEW_CEPC_PS_DUMMY TYPE STRING,END OF T_EKKO_STR. DATA: WA_BIW_CEPC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BIW_CEPC_STR-MANDT sy-vline
WA_BIW_CEPC_STR-KOKRS sy-vline
WA_BIW_CEPC_STR-PRCTR sy-vline
WA_BIW_CEPC_STR-DATETO sy-vline
WA_BIW_CEPC_STR-DATEFROM sy-vline
WA_BIW_CEPC_STR-ERSDA sy-vline
WA_BIW_CEPC_STR-USNAM sy-vline
WA_BIW_CEPC_STR-MERKMAL sy-vline
WA_BIW_CEPC_STR-ABTEI sy-vline
WA_BIW_CEPC_STR-VERAK sy-vline
WA_BIW_CEPC_STR-VERAK_USER sy-vline
WA_BIW_CEPC_STR-WAERS sy-vline
WA_BIW_CEPC_STR-NPRCTR sy-vline
WA_BIW_CEPC_STR-LAND1 sy-vline
WA_BIW_CEPC_STR-ANRED sy-vline
WA_BIW_CEPC_STR-NAME1 sy-vline
WA_BIW_CEPC_STR-NAME2 sy-vline
WA_BIW_CEPC_STR-NAME3 sy-vline
WA_BIW_CEPC_STR-NAME4 sy-vline
WA_BIW_CEPC_STR-ORT01 sy-vline
WA_BIW_CEPC_STR-ORT02 sy-vline
WA_BIW_CEPC_STR-STRAS sy-vline
WA_BIW_CEPC_STR-PFACH sy-vline
WA_BIW_CEPC_STR-PSTLZ sy-vline
WA_BIW_CEPC_STR-PSTL2 sy-vline
WA_BIW_CEPC_STR-SPRAS sy-vline
WA_BIW_CEPC_STR-TELBX sy-vline
WA_BIW_CEPC_STR-TELF1 sy-vline
WA_BIW_CEPC_STR-TELF2 sy-vline
WA_BIW_CEPC_STR-TELFX sy-vline
WA_BIW_CEPC_STR-TELTX sy-vline
WA_BIW_CEPC_STR-TELX1 sy-vline
WA_BIW_CEPC_STR-DATLT sy-vline
WA_BIW_CEPC_STR-DRNAM sy-vline
WA_BIW_CEPC_STR-KHINR sy-vline
WA_BIW_CEPC_STR-BUKRS sy-vline
WA_BIW_CEPC_STR-VNAME sy-vline
WA_BIW_CEPC_STR-RECID sy-vline
WA_BIW_CEPC_STR-ETYPE sy-vline
WA_BIW_CEPC_STR-TXJCD sy-vline
WA_BIW_CEPC_STR-REGIO sy-vline
WA_BIW_CEPC_STR-KVEWE sy-vline
WA_BIW_CEPC_STR-KAPPL sy-vline
WA_BIW_CEPC_STR-KALSM sy-vline
WA_BIW_CEPC_STR-LOGSYSTEM sy-vline
WA_BIW_CEPC_STR-LOCK_IND sy-vline
WA_BIW_CEPC_STR-PCA_TEMPLATE sy-vline
WA_BIW_CEPC_STR-SEGMENT sy-vline
WA_BIW_CEPC_STR-EEW_CEPC_PS_DUMMY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.